25 KVA Single Pole Transformer-14.4/0.12 * 0.24 KV|Canada 2025

25 KVA Single Pole Transformer-14.4/0.12 * 0.24 KV|Canada 2025

Naha ea thomello: Canada 2025
Matla: 25kVA
Matla: 14.4-0.12/0.24kV
Sebopeho: Tšireletso ea Dual Voltage & IFD
Romela Inquiry

Jiangshan Scotech Electrical Co., Ltd ke e 'ngoe ea baetsi le barekisi ba tšepahalang ba 25 kva single pole transformer-14.4/0.12*0.24 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

 

25 kVA single pole transformer

SCOTECH - moetsi le morekisi ea tšepahalang oa 25 kVA

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

25 kVA Single{{1}Phase Pole Mounted Transformer ho tsoa SCOTECH ho bonolo ho e kenya holim'a lipalo tsa lisebelisoa tse holimo. E tšepahala haholo 'me e tla le lisebelisoa tsa bohlokoa. Likarolo{4}tse kang tsena li loketse libaka tsa mahaeng kapa tse nang le mela e holimo. Li kengoa habonolo, li hlokomeloa habonolo, 'me li na le litšenyehelo-tse sebetsang hantle bakeng sa batho ba bangata{7}lichaba.

Transfoma ena e theolela{0}}motlakase oa motlakase o mongata (24,940 GRDY/14,400 V) ho isa sebakeng se sireletsehileng sa 120/240 V bakeng sa matlo le likhoebo tse nyane ho marang-rang a 60 Hz. E na le mapheo a aluminium le mokokotlo oa tšepe oa laminated. Sebetsa se Kholo ho feta kapa se lekana le 98.87%, ha ho{11}}tahlehelo ea moroalo oa 85 W le tahlehelo ea mojaro oa 254 W. Ho sitisoa ha eona ke 1.97% (±10%), ho netefatsa hore motlakase o tsitsitse ha o laeloa.

E kenyelletsa Non-Load Tap Changer (NLTC) e nang le sebaka sa ±2×2.5% sa ho pompo bakeng sa ho fetola motlakase. 18 kV high-voltage arrester e sireletsa transformer hore e se ke ea felloa ke matla le lehalima. Setsi sena se sebelisa ONAN pholileng le liminerale tse kenyang oli, tse nang le tanka e tiisitsoeng bakeng sa ts'ebetso e tšepahalang ea kantle. Transformer e sebelisa pholiso ea ONAN le ho kenya oli ea liminerale, e nang le moralo oa tanka e tiisitsoeng bakeng sa ts'ebetso e tšepahalang ea kantle. E ka kenngoa habonolo holim'a lipalo tsa lisebelisoa tsa lehong kapa tsa konkreite, tse hlokang tlhokomelo e fokolang.

E loketse libaka tsa bolulo, mapolasi le lisebelisoa tse nyenyane tsa khoebo, transformer ena e fana ka matla a ka tšeptjoang ho marang-rang a kabo ea mahaeng le a litoropong, li-extensions tsa marang-rang, le libaka tse atisang ho ba le liketsahalo tse matla kapa tsa lehalima.

 

 

 

1.2 Tlhaloso ea Setsebi

Tlhaloso ea 25kVA pole transformer e le 'ngoe le leqephe la data

E fetisetsoa ho
Canada
Selemo
2025
Mofuta
Pole mounted transformer
Standard
CSAC2.2-06/C802.1-23
Rated Power
25KVA
Khafetsa
60HZ
Polarity
Keketso
Mokhahlelo
Motho a le mong
Mofuta oa ho Pholisa
ONA
Mokelikeli o thibelang metsi
Oli ea Liminerale
Voltage ea mantlha
24940GRDY/14400 V
Motlakase oa bobeli
120/240 V
Sehlopha sa Vector
Ii6
Lintho Tse Hlahang
Aluminium
Tšitiso
1.97%(±10%)
Sebetsa le Tahlehelo Standard
E kholo ho feta kapa e lekana le 98.87%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
85 W
Loss Loss ka Rated Voltage
254 W
Lisebelisoa
18kV HV Motšoantšisi

 

1.3 Litšoantšo

25kVA setšoantšo se nang le poleiti e le 'ngoe le nameplate

25 kVA single pole transformer drawing 25 kVA single pole transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

25 kVA single pole transformer iron core

Pelo ea -mohau oa transfoma ke mokokotlo oa eona oa makenete, hangata o entsoe ka masela a masesaane a tšepe. Mokotla o thusa matla a khoheli ho tsamaea habonolo lipakeng tsa mapheo a mantlha le a bobeli. Sena se lumella transformer ho fana ka motlakase o tsitsitseng ka tahlehelo e tlase ea matla le ho sebetsa ka ts'epo letsatsi le leng le le leng.

 

2.2 Ho tsubella

Li-transformer tsena li na le foil ea aluminium bakeng sa lehlakore la-voltage e tlase. Ho sebelisoa terata ea koporo bakeng sa-lehlakore la motlakase o phahameng. Feme e tsamaisa lits'ebetso tsena tse peli ka thoko ka mechini e inehetseng le basebetsi ba koetlisitsoeng. Re etsa liteko tsa ho koala, boholo, le ho hanyetsa ha khoele e 'ngoe le e 'ngoe ho etsa bonnete ba hore yuniti ka 'ngoe e sebetsa kamoo e reriloeng kateng.

25 kVA single pole transformer coil

 

2.3 Tanka

25 kVA single pole transformer oil tank

'Mele oa tanka, sekoaelo, le likarolo tsohle tse ka ntle tse cheselitsoeng ka ntle li sebelisoa ho thibela{0}corrosion treatment ka mor'a hore li tjhesehele ho ikamahanya le libaka tse ka ntle, tse mongobo, tse lebopong la leoatle, le tse ling tse atisang ho rula kapa ho fafatsa letsoai. Ts'ebetso ena e tiisa hore transformer e ka sebetsa ka mokhoa o tsitsitseng nako e telele, esita le libakeng tse nang le moea o matla oa leoatle le mongobo o phahameng.

 

 

03 Ho etsa liteko

25 kVA single pole transformer testing-1
25 kVA single pole transformer testing-2

 

 

04 Ho paka le ho tsamaisa

4.1 Ho paka

25 kVA single pole transformerpacking-1
25 kVA single pole transformerpacking-2

 

4.2 Ho tsamaisa thepa

25 kVA single pole transformer shipping-1
25 kVA single pole transformer shipping-2

 

 

05 Mehopolo ea Polokeho le Tlhokomelo

25 kVA single pole transformer
 

Le libakeng tse thata tse lebopong la leoatle,{0}li-transformer tse ka holim'a lipalo li lula li tšepahala, empa tlhahlobo ea ka mehla e bohlokoa. Letsoai-moea o tletseng, lifefo tsa lehlabula, le leqhoa la mariha li ka potlakisa ho bola kapa ho baka khatello ea kelello. Likotsi tse ka sehloohong li kenyelletsa:
• Ho lutla ha oli
• Lehalima{0}} le bakile ho hloleha
• Lits'oants'o tse ngata nakong ea tlhokahalo ea tšohanyetso
Ho fokotsa likotsi tsa ho hloa, lits'ebeletso hangata li itšetleha ka li-sensor tsa mocheso le tlhahlobo ea drone ho lekola boemo ba transfoma ho tloha fatše.

 

Hot Tags: single pole transformer, moetsi, mofani oa thepa, theko, litšenyehelo