Setsi sa Motlakase ke eng

Phetoho ea Voltage le Kabo ea Matla
Li-substations li phahamisa maemo a motlakase ho ea holimo kapa ho theoha ho netefatsa hore motlakase o fetisoa libakeng tse telele le ho ajoa ka mokhoa o sireletsehileng ho basebelisi ba ho qetela, ho fokotsa tahlehelo ea matla ho pholletsa le marang-rang.
Tšireletso le Taolo ea Thepa ea Motlakase
Ka li-relay tsa ts'ireletso, li-circuit breaker, le litsamaiso tsa taolo, liteishene li bona liphoso, li arola likarolo tse sa tloaelehang, le ho sireletsa lisebelisoa tsa bohlokoa ho boloka botsitso ba sistimi le polokeho ea ts'ebetso.
Tlhokomelo, Boiketsetso, le Kopanyo ea Sistimi (SCADA)
Liteishene tsa sejoale-joale li na le lisebelisoa tsa tlhahlobo le likhokahano tse lumellang-ho fumana data ka nako ea 'nete, taolo ea remoutu, le khokahanyo e se nang mathata le sethala sa SCADA, ho ntlafatsa ts'ebetso e sebetsang hantle le ts'epahalo ea grid.
Mefuta ea rona ea Substation Transformer
- Re fana ka litharollo tse felletseng tsa litsi - ho tloha mohopolong ho isa ho ts'ebetsong - ho khotsofatsa tlhoko e ntseng e eketseha ea kabo ea motlakase e tšepahalang, e bolokehileng le e sebetsang hantle.
- Ebang ke lits'ebeletso, basebelisi ba indasteri, limela tsa matla a ka nchafatsoang, kapa marang-rang a litšebeletso, re fana ka lits'ebetso tsa turnkey tse lumellanang le IEC, IEEE, ANSI, CSA le litekanyetso tsa ts'ebeliso ea tikoloho.
- Mofuta o mong le o mong oa seteishene o ka hlophisoa ho latela maemo a motlakase a hlokahalang, matla, le litlhophiso ho kopana le maemo a lehae le maemo a projeke.
- Setsi sa yuniti
Transformer - Compact Substation
Transformer - Containerized Substation
Transformer - Koloi{0}e kentsoeng mohaleng
setsi sa motlakase Transformer
Unit Substation Transformer
Unit substation transformer ke -e kopantseng pele, ea kabo ea motlakase e momahaneng e theolang matla a mahareng a-voltage hore a fihle ho matla a bolokehileng, a ka sebelisoang. Moetso oa eona o haufi-o kopanya transformer le lisebelisoa tsa mantlha le tsa bobeli haufi le mojaro, o fokotsa bolelele ba cabling le bese, o fokotsa tahlehelo ea motlakase, o ntlafatsa taolo ea motlakase, le ho matlafatsa ts'epahalo ea lits'ebeletso.
- Ho fihla ho 10 MVA 34.5 kV
- Matla a lekantsoeng ho fihla ho 10 MVA
- Boemo bo lekantsoeng ba ho kenella ho fihla ho 161 kV
- Ho phahama ha mocheso: 55 degree, 65 degree, 55/65 degree, 45 degree
Custom Features
- Electrostatic shielding ho fokotsa tšitiso.
- Tšireletso ea - ea maemo a holimo e kahara kutu (C5-M, marine/indasteri) le moralo o hananang le litšisinyeho tsa lefatše.
- Maemo a tloahelehileng a bushing le wiring (ho kena ka holimo / lehlakoreng, menyetla e khethehileng).
- Moralo{0}ka potlako o nang le menyetla ea ho bula lifene, libaka tsa ho phahamisa, le litheminale tsa ho qala kapele.
- -Moetso o tlase oa lerata ho latela litlhoko tsa bareki.
- Impedanance e khethehileng, mamello, le K-meetso ea lintlha bakeng sa ho sebetsana le meroalo e ntlafalitsoeng le e sa thekeseleng.
- E ts'ehetsa{{0}mofuta o tlatsitsoeng, o omileng-, le meralo e khethehileng ea li-transformer bakeng sa lits'ebetso tse ikhethileng

Compact Substation Transformer
The compact substation, e tsejoang hape e le prefabricated substation, ke feme{0}}e kopantseng, e kentsoeng ka botlalo ea phano ea motlakase e kopanyang{1}}voltage switchgear, transformer, le{2}}tlase{2}}sesebelisoa sa motlakase hore e be sebopeho se kopaneng. E etselitsoe bakeng sa phetoho e nepahetseng ea matla le ho ajoa, e na le moalo o tiileng oa tšepe o nang le litšireletso tse ngata, e leng se etsang hore e tšoanele lisebelisoa tsa ka hare le tsa ka ntle lits'ebetsong tsa bolulo, tsa khoebo le tsa indasteri.
- Ho fihla ho 20000 KVA 72 kV
- Bokhoni ba Transformer Bo ka tlase ho kapa bo lekana le 20000 KVA
- Matla a phahameng a lekantsoeng: 12 - 72 kV
- Boemo ba tšireletso bo katiloeng: IP54
- Boholo ba bophahamo: 5000 metres
- Mokhoa oa ho beha leihlo o ka morao o thusa{0}}ho lekola nako ea 'nete ea lintlha tsa bohlokoa, ho kenyeletsoa mocheso oa mantlha oa ho kopana, ho ntša metsi, le khanya ea arc.
- Ho sebelisoa mekhoa e fapaneng ea ho kenya letsoho, joalo ka mohatsela oa khase o baballang tikoloho, ho kenyeletsoa ha moea, ho tiisa moea o tiileng, le -ea sireletsang moea.

Containerized Substation Transformer
Transformer e nang le li-containerized substation ke sesebelisoa se -se kopaneng, sa modular sa kabo ea motlakase se bolokang-voltage switchgear, transformer, le lisebelisoa tse ling ka har'a sets'oants'o sa tšepe se tšoarellang nako e telele. E etselitsoe ho romelloa ka potlako, ho tsamaea ha bonolo, le ho kenya li-turnkey, 'me e fana ka litharollo tsa motlakase tse tšepahalang, tsa boemo ba leholimo{4}}bakeng sa libaka tsa nakoana, tse kentsoeng ka ntle, merero ea indasteri, le -mesebetsi ea bohlokoa.
- Ho fihla ho 600000kVA 7550kV
- Matla a phahameng a lekantsoeng: 12 - 550 kV
- Nako e telele ea ho mamella-nako e khutšoanyane: 63 kA;
- Boemo ba ts'ireletso: IP55
Custom Features
- Mefuta ea sebopeho sa mabokose e kenyelletsa: sebopeho sa cabin e entsoeng esale pele, sebopeho se tloaelehileng sa setshelo;
- Boholo ba lijana tsa modular (10′–40′ ISO) bakeng sa litlhoko tse fapaneng tsa sebaka.
- Likhetho tsa moralo oa kahare oa arc-proof bakeng sa polokeho e ntlafalitsoeng.
- Tšireletso ea lehalima, mabone a tšohanyetso, lialamo, le lisebelisoa tsa tšireletso.
- Liteishene tsa solar PV tsa mohato o holimo tse nang le likarolo tse kopaneng tsa inverter/DC.
- Likhetho tsa ho iketsetsa gridi, ho beha leihlo hole, le kopanyo ea SCADA
- Likhetho tsa li-cast resin, tse tlatsitsoeng ka oli, kapa li-air-insulated tse ipapisitseng le litlhoko tsa projeke.

Koloi-Sepalangoang sa Transformer
Koloi{{0}mounted mobile transformer ke k'haravene- kapa chassis-seteishene sa mobile se palamisitsoeng se kopanyang-voltage transformer, MV/LV switchgear, lisebelisoa tsa ts'ireletso, le lisebelisoa tse ling hore e be yuniti e le 'ngoe. E etselitsoe ho tsamaisoa ka potlako le ts'ebetso ea kantle, e fana ka tharollo ea motlakase ea nakoana e feto-fetohang, e tšepahalang bakeng sa ts'ohanyetso, tlhokomelo le lits'ebetso tsa sebaka se hole.
- Ho fihla ho 240000kVA 330 kV
- Matla a phahameng a lekantsoeng: 12 - 330 kV
- Nako e telele ea ho mamella-nako e khutšoanyane: 63 kA;
- Tlhokomelo le taolo e bohlale - e hahelletsoeng ka har'a SCADA/sistimi ea ho beha leihlo ka remoutu bakeng sa liparamente tsa nako ea sebele (voltage, hajoale, thempereichara) le remote control.
- Tšireletso e phahameng ea tikoloho - Likarolo tse lekantsoeng ka IP55, tse thibelang ho sisinyeha le tse thibelang kutu bakeng sa tikoloho e thata (mongobo o phahameng, lifefo tsa lehlabathe, libaka tse lebopong la leoatle).

Litšebeletso tseo re fanang ka tsona

Re fana ka litharollo tsa liteishene tsa motlakase tsa turnkey, ho tloha ho litherisano le phepelo ea lisebelisoa ho isa ho ho kenya, ho fana ka khomishene, koetliso, le ts'ehetso{0}ka mor'a thekiso. Sehlopha sa rona sa litsebi se netefatsa ts'ebetso e bolokehileng, e ts'epahalang le ts'ehetso e felletseng ea bophelo bohle bakeng sa kabo ea matla e phahameng-.
Ke Hobane'ng ha U Re Khetha

Ha u na bonnete ba se U Lokelang?
Baenjiniere ba rona ba motlakase ba ka u tataisa ho fumana tharollo e nepahetseng bakeng sa litlhoko tsa projeke ea hau.
Projects Reference
LBH
P: Li-transformer tsa hau li latela litekanyetso life tsa machaba?
K: Li-transformer tsa rona li entsoe, li entsoe, le ho lekoa ho latela maemo a ANSI/IEEE C57, NEMA, DOE, IEC, CSA, le UL®, joalo ka ha ho sebetsa. Yuniti ka 'ngoe e kopana kapa e feta litlhoko tse nepahetseng tsa taolo le ts'ebetso bakeng sa ts'ebeliso ea lefats'e le lits'ebetso tsa indasteri.
P: Ke liteko life tsa feme tse etsoang pele ho pepa?
A: Transformer e 'ngoe le e' ngoe e etsa liteko tse felletseng tsa fektheri ho latela litekanyetso tse sebetsang. Mananeo a liteko a ka etsoa ho latela litlhoko tsa morero, 'me Factory Witness Testing (FAT) e fumaneha sebakeng sa{1}}kapa ka khokahanyo e sireletsehileng ea video.
P: U fana ka eng ka mor'a-lithekiso le tšehetso ea tekheniki?
K: Re fana ka litokomane tse felletseng tsa tekheniki, litlaleho tsa tlhahlobo ea lifeme, tataiso ea ho kenya, le ts'ehetso e tsoelang pele ea boenjiniere ho netefatsa ts'ebetso e bonolo, ts'ebetso e tšepahalang, le{0}}ts'ebetso ea nako e telele bophelong bohle ba sesebelisoa sa transfoma.
P: Na o fana ka tharollo ea li-transformer tsa mobile substation?
A: Ho joalo. Re fana ka litharollo tsa li-transformer tsa nakoana le tsa nakoana tse etselitsoeng karabelo ea tšohanyetso, ho tima tokiso, le ho romelloa ka potlako, ho fana ka phepelo ea motlakase e tšepahalang ha liteishene tsa ka mehla li le sieo.
P: Na li-substations li ka ntlafatsoa ka theknoloji e ncha?
A: Ho joalo. Liteishene tsa Transformer li ka ntlafatsoa ka-li-transformer tse sebetsang hantle haholo, lisebelisoa tse tsoetseng pele tsa ho beha leihlo, le mahlale a marang-rang a marang-rang ho ntlafatsa ts'ebetso, ts'epo, le ho ikamahanya le litlhoko tsa grid nakong e tlang.
Lisebelisoa tse Amanang
Kopa Khoutu bakeng sa Tharollo ea Seteishene sa Hao