50 Kva Pole Mounted Transformer-25/0.347 KV|Canada 2024

50 Kva Pole Mounted Transformer-25/0.347 KV|Canada 2024

Naha ea thomello: Canada 2024
Matla: 50 kVA
Matla: 25/0.347kV
Tšobotsi:{0}voltage double bushings e phahameng
Romela Inquiry

 

50 kva pole mounted transformer

Transformer e ka tšeptjoang le e sebetsang hantle ea 50 kVA e nang le-voltage double bushings le tšireletso ea lehalima bakeng sa matla a sireletsehileng a kantle.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

Li-transformer tse tharo tsa 50 kVA single-phase pole{2}}li rometsoe ho moreki oa Canada ke Scotech ka 2024. Ho tsamaisana le tiisetso le maemo a CSA C2.2-06. Lihlopha tsena li etselitsoe hore li sebetse ka matla a motlakase a 25 kV, a fana ka 0.347 kV ka lehlakoreng la bobeli, ka matla a phahameng a 50 kVA. Ba sebelisa pholiso ea oli ea tlhaho ea ONAN le ho kenngoa ha oli ea diminerale, ho kopantsoe le polarity e eketsehileng le sehlopha sa vector Ii6, tseo hammoho li thusang ho boloka motlakase o tsitsitseng le ho fana ka matla a matla.

Maqhubu a aluminium a fokotsa boima ba 'mele le litšenyehelo. 2.3% litekanyo tsa ho se sebetse hantle-nako ea potoloho le motlakase. NLTC e nang le mehato e ±2 × 2.5% e boloka sephetho se tsitsitse ha se le tlas'a khatello. 33 kV polymer e thibelang lehalima le lihlahla tse peli tse phahameng-li sireletsa khahlanong le lehalima le matla a mangata. PRD e lokolla khatello ka mokhoa o sireletsehileng.

Motsoako oa motlakase o tloaelehile Amerika Leboea le marang-rang a kabo ea Canada. E loketse libaka tsa mahaeng, lihlopha tsa bolulo, le likhoebo tse nyenyane. E sebetsa ho li-circuits tsa phepelo, marang-rang a li-ring, le mela ea makala. E matla bakeng sa ts'ebeliso ea ka ntle{{3}ka ntle, esita le libakeng tsa mahalima a phahameng. E fana ka matla a tsitsitseng, a sebetsang hantle, a ka tšeptjoang.

 

1.2 Tlhaloso ea Setsebi

50 kva pole mounted transformer specification le data sheet

E fetisetsoa ho
Canada
Selemo
2024
Mofuta
Pole Mounted Transformer
Standard
CSA C2.2-06
Rated Power
50kVA
Khafetsa
60HZ
Polarity
Kekeletso
Mokhahlelo
1
Mofuta oa ho Pholisa
ONA
Mokelikeli o thibelang metsi
Oli ea Liminerale
Voltage ea mantlha
25 kV
Motlakase oa bobeli
0.347 kV
Sehlopha sa Vector
Ii6
Lintho Tse Hlahang
Aluminium
Tšitiso
2.3 %
Katleho
98.84%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
135 kV
Ho Lahleheloa ke Moroalo
705 kV
Lisebelisoa
Motshwari

 

1.3 Litšoantšo

50 kva pole mounted transformer litekanyo le lintlha tsa boima ba 'mele

50 kva pole mounted transformer drawing 50 kva pole mounted transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Transformer Core ea rona e entsoe ka tšepe e batang-e kolobisitsoeng ka silicon. E na le tahlehelo e tlase ea tšepe le matla a matla a makenete. Bokaholimo bo na le seaparo se ts'oanang. E thibela oxidation mme e hanela kutu. Laminations li phuthetsoe ka thata. Li-insulated layers li boloka matla a mochine le ho fokotsa tahlehelo ea hona joale ea eddy. Koko e tiisitsoe ka thata. E fokotsa ho thothomela le lerata ha{8}}e sa sebetse kapa ha lehalima le otla.

 

2.2 Ho tsubella

Pele ho matsoelintsoeke, tsela le polarity li tlameha ho hlalosoa ka ho hlaka ho netefatsa matšoao a nepahetseng le ho thibela liphoso tsa mokhahlelo. Khoele e 'ngoe le e' ngoe e sebelisa terata e hloekileng ea aluminium e nang le conductivity e ntle le ho hanyetsa kutu. Maqhubu a latela polarity e nepahetseng. Matla a tlase{{3}a ka hare, a phahameng-ka ntle. Insulation e thata, tsitsipano e laoloa. Li-ducts tsa oli le ho hatella li tiisa hore ho pholile le ho ba matla.

50 kva pole mounted transformer winding

 

2.3 Tanka

50 kva pole mounted transformer oil tank

Tanka ea rona ea li-transformer e entsoe ka li-flange tse matla le litšehetso tse ntseng li hola ho ts'oara li-surges ka mokhoa o sireletsehileng. Phanele e ka hodimo e ka jara boima ba motshwari le matla a ka ntle. Likoti tse kenang li bataletse ebile li sireletsehile. Thepa ea tanka e hanela mocheso le khatello ea lehalima kapa ts'ebetso. Ho tiisa ka li-gaskets tsa rabara ho thibela ho lutla ha oli. Bokaholimo bo khahlanong le-ho bola. Sebaka sa tlhokomelo se boloketsoe sebaka sa ho ts'oaroa habonolo ntle le ho ama ho tiisa ka kakaretso.

 

2.4 Kopano ea ho Qetela

Kopano ea Core le Maqhubu
Kenya li-winding tse phahameng{{0}le tse tlase{1}} tsa maqhubu a motlakase holim'a mantlha, 'me u netefatse hore li-insulation le concentricity.
Ho kenya 'mele
Beha kopano ea mantlha le ea matsoeli ka har'a tanka ea oli.
Kenya li-lead le lihlahla tsa insulating, ho etsa bonnete ba ho tiisa ka nepo.
Ho Tlatsa Transformer Oli
Entela oli ea transformer e tlhotliloeng, ho netefatsa hore e hloekile ebile ha e na litšila.
Kenya Lisebelisoa tsa Kantle
Hokela li-valve tsa polokeho, li-gauge tsa boemo ba oli, le likhokahano tsa terminal.

50 kva pole mounted transformer active part

 

 

03 Teko

Teko ea Teko le Teko e Tloaelehileng

CSA C2.2-06(R2022) E le 'ngoe-mohato o le Mong-mehato e meraro{4}}li-transformer tse tletseng metsi

CSA C802.1-13(R2022) Bonyane bo sebetsang hantle bakeng sa li-transformer tse tletseng metsi
 

1. Litekanyo tsa ho hanyetsa
2. Karo-karolelano Liteko
3. Polarity Test
4. Ha ho Tahlehelo ea Mojaro 'me Ha ho na Mojaro Hona Joale
5. Litahlehelo tsa Meroalo le Matla a ho Impedance
6. Teko ea Voltage e sebelisitsoeng
7. Induced Voltage E mamella Teko
8. Tekanyo ea ho hanyetsa Insulation
9. Teko ea Leak e nang le Khatello ea Li-transformers tse qoelitsoeng ka Metsi
10. Tlhahlobo ea oli

 

04 Ho paka le ho Romela

50 kVA single-phase pole transformer packing
50 kVA single-phase pole transformer shipping

05 Sebaka le Kakaretso

50 kVA single-phase pole transformer

Scotech 50 kVA single-phase pole transformer – lightweight aluminium windings. E sebelisa pholiso ea ONAN. NLTC tap changer le tšireletso ea lehalima ea 33 kV li boloka matla a tšepahala a bile a bolokehile. E fana ka matla a ka ntle a sebetsang hantle bakeng sa marang-rang a mahaeng le a bolulo.

 