SCOTECH Transformer Tank Solutions bakeng sa Indasteri ea Matla a Lefatše
Joalo ka moetsi oa tanka ea li-transformer tse tšepahalang, SCOTECH e fana ka litanka tsa li-transformer tse tloaelehileng ho bahlahisi, likonteraka tse akaretsang tsa EPC, lik'hamphani tse lokisang, le lik'hamphani tse sebetsang lefatšeng ka bophara.
Ebang ke bakeng saPole{{0}Mounted Transformers, Pad{{0}Mounted Transformers, Kabo ea Transformers, Li-transformer tsa matlakapali-transformer tse khethehilengre na le tharollo ea tanka e nepahetseng.
• Mekhoa e tloaelehileng bakeng sa mefuta eohle ea li-transformer
• Litanka tse tiisitsoeng ka ho feletseng,{0}tse sa kang tsa lutla
• Superior corrosion protection (>Teko ea 1000h ea letsoai la spray)
• Ho lumellana le IEEE / IEC / CSA/ANSI le litekanyetso tse ling tsa machaba
Mefuta ea Tanka ea Transformer Re e Etsa
Re etsa litanka tsa li-transformer tse tloaelehileng bakeng sa mefuta e fapaneng ea ho kenya le litekanyetso tsa motlakase, ho kopana le IEEE / IEC
litekanyetso le litlhoko tsa OEM.
E etselitsoe -li-phase pole mounted transformer, tse loketseng lisebelisoa tsa kabo ea kantle.
• Reite e sebetsang:Ho fihlela ho 1000 kVA
• Sehlopha sa Voltage:Ho fihlela ho 34.5 kV
• Sebopeho sa Tanka:Tanka ea oli e tiisitsoeng ka botlalo{{0}e nang le bopaki ba ho dutla
• Melao e Tloaelehileng:IEEE, IEC, ANSI, CSA, NEMA, le litekanyetso tsa DOE
E sebelisoa lits'ebetsong tsa kabo ea matla a ka tlas'a lefatše le a bolulo a nang le sebopeho se kopaneng le ts'ireletso ea kutu.
• Reite e sebetsang:Ho fihlela ho 250 KVA
• Sehlopha sa Voltage:Ho fihlela ho 34.5 KV
• Moralo oa Polokeho:Tamper-Sehaho sa tanka e manganga
• Melao e Tloaelehileng:IEEE, ANSI, CSA, NEMA, le litekanyetso tsa DOE.
Litanka tse boima- tsa li-transformer tse etselitsoeng-liphetoho tse kentsoeng ka mekhahlelo e meraro molemong oa khoebo le indastering.
• Reite e sebetsang:Ho fihlela ho 10000 KVA
• Sehlopha sa Voltage:Ho fihlela ho 46 kV
• Qetella & Tšireletso ea Corrosion:hot-dip galvanized finish kapa tšepe e feletseng
• Melao e Tloaelehileng:IEEE / ANSI / CSA/DOE/NEMA
Litanka tsa li-transformer tse tloaelehileng bakeng sa kabo le li-transformer tsa motlakase, tse loketseng li-substations le merero ea ts'ebeliso.
• Lintlha tsa Transformer:ho fihlela ho 500 MVA
• Sehlopha sa Voltage:ho fihlela ho 330 kV
• Litšoantšiso tsa ho penta litanka:> Teko ea ho fafatsa letsoai lihora tse 1000
• Melao e Tloaelehileng:IEC 60076 / IEEE C57 / CSA/ ANSI
Ke Hobane'ng ha Litanka tsa Rōna tsa Oli ea Transformer li Tšeptjoa
E Enjenetsoe ho Maemo a Machaba
Litanka tsohle tsa rona tsa oli ea transfoma li etselitsoe ho kopana le IEC, IEEE, CSA le litekanyetso tse ling tse hlokahalang, ho netefatsa ts'ebetso e ts'epahalang le ho latela litlhoko tse thata tsa motlakase le mochini tsa Europe le Amerika Leboea.
Customizable ka ho Feletseng ho Litlhoko tsa Hao
Re etsa litanka tsa li-transformer ka thata ho latela litšoantšo tsa hau, litlhaloso le litlhoko tsa projeke.
Superior Welding & Leak-Bopaki ba Moralo
Mekhoa ea rona e tsoetseng pele ea ho cheseletsa, hammoho le khatello e matla le liteko tse lutlang, li tiisa{{0}oli ea nako e telele{1}}e tiileng le bots'epehi tlas'a maemo a boima.
Kalafo e Khahlanong le{0}Tlhahiso ea Corrosion Surface
Ho tloha ho hot-dip galvanization ho ea ho polyester sprayed polyester powder, polyurethane topcoats, le stainless steel options, re sireletsa litanka tsa hau tikolohong e thata ea kantle le ho netefatsa hore li tšoarella nako e telele.
Likhetho tse Phahameng- tsa Boleng
Tanka ea rona ea transfoma e sebelisa carbon steel, stainless steel, kapa carbon-hybrid steel hybrid. Likhetho tsa tšepe tse sa hloekang li kenyelletsa 409 le 304L, tse netefatsang khanyetso e ntle ea kutu bakeng sa tanka.
Optimized Thermal Performance
Litanka tsa rona tsa oli tsa transfoma li sebelisa li-radiator tse entsoeng ka masenke kapa tse se nang tšepe kapa meralo ea ho futhumatsa tanka e entsoeng ka masenke ho ntlafatsa ts'ebetso ea ho felisa mocheso le ho netefatsa mocheso o tsitsitseng oa oli tlas'a maemo a sa khaotseng a ts'ebetso.
Lisebelisoa

Tank For Pole Mounted Transformer
E sebedisetsoa-mohato o le mong oa ho arola li-transformer tse palamisitsoeng lipalong tsa lisebelisoa, tse fumanehang hangata lithapong tsa motlakase bakeng sa phepelo ea motlakase libakeng tsa bolulo le tsa khoebo metseng ea litoropo le ea mahaeng.

Tank For Single Phase Pad Mounted Transformer
E sebelisoa ho litsamaiso tsa kabo ea ka tlas'a lefatše bakeng sa phepelo ea motlakase sebakeng sa heno libakeng tse kang tikolohong, literateng, le nts'etsopele ea mahaeng, e fanang ka tharollo ea boemo bo kopanetsoeng e sireletsehileng{0}.

Tank For Three Phase Pad Mounted Transformer
E sebelisoa literekeng tsa khoebo, tsa indasteri, le{0} tse kholo tsa bolulo bakeng sa{1}kabo ea motlakase ea mokhahlelo oa boraro-ea mokhahlelo oa boraro. Litanka tsena li fana ka tšireletso e tšepahalang ea tikoloho le ho pholisa li-transformer tse fanang ka litsi tsa mabenkele, lifeme, le{4}}ntlafatso ea bareki ba bangata.

Tanka Bakeng sa Kabo
Transformer
E etselitsoe li-transformer tse sebelisoang mohatong oa ho qetela oa phetoho ea motlakase oa sistimi ea kabo ea motlakase, e isang motlakase ka kotloloho ho batho ba -basebelisi ba libaka tsa bolulo, tsa khoebo, le liindasteri tse bobebe.

Tanka Bakeng sa Matla
Transformer
E sebelisoa ka{0}}motlakase oa motlakase o phahameng le ho amoheloa lifemeng le liteishene tse fehlang motlakase, e thusa ho tsamaisa -mahole a malelele a motlakase le ho hokela marang-rang ka har'a marang-rang.

Tanka Bakeng sa Khethehileng
Transformer
E etselitsoe li-transformer lits'ebetsong tse ikhethileng tsa indasteri le tikolohong e thata, joalo ka metallurgy (rectifier / sebōpi), meepo, lipalangoang tsa literene, mapolasi a moea a tsoang kantle ho naha, le merero e meng e ikhethang.
Na o hloka Tharollo ea Tanka ea Transformer e Tšepahalang le e Iketselitsoeng?
Re romelle litšoantšo tsa hau kapa lintlha tsa tekheniki bakeng sa quotation e potlakileng.
Hobaneng o re Khetha joalo ka Moetsi oa Tanka ea Transformer
Re litsebi tsa ho etsa litanka tsa li-transformer tse nang le boiphihlelo ba lilemo tsa ho rala le ho etsa-boleng bo phahameng
oli-litanka tsa transfoma tse tlatsitsoeng ka oli. Boitsebi ba rona bo akaretsa-pad-tse phanngoeng, tse tsamaisoang, le li-transformer tsa motlakase,
'me re tšehetsa OEM ka bobeli le meralo ea tloaelo ka botlalo ho fihlela litlhoko tsa projeke ea hau.
Ka-Ho etsoa ha Transformer Tank Manufacturing
Litanka tsa rona kaofela li entsoe ka-ka tlung, ho netefatsa taolo e felletseng holim'a boleng le ho nepahala.
• Ho seha poleiti ea tšepe le ho theha ho sebelisa mechine e tsoetseng pele ea ho kobeha ea CNC
• Automated le pukwanana tjheseletsa etsoa ke pakiloeng tjheseletsa bakeng sa manonyeletso bohlokoa
• Tlhahlobo ea boholo le tlhahlobo ea khatello / ho lutla pele ho pelehi
Thepa e tsoetseng pele ea Welding & Form Thepa
Feme ea rona e hlomelloa ka-ea{1}}-lisebelisoa tsa bonono ho netefatsa boleng ba boleng bo holimo:
• Mechini e kobehang ea CNC le-e etsang mosebetsi o boima bakeng sa ho etsa masela a nepahetseng
• Automatic tjheseletsa litsamaiso bakeng sa boleng bo tsitsitseng tjheseletsa
• Litšepe tse nang le boiphihlelo le tse netefalitsoeng bakeng sa li-welds tse bohlokoa tse fihlelang litlhoko tsa mochini le ho tiisa
Taolo e Matla ea Boleng le Teko ea ho Lutla
Re sebelisa mekhoa e matla ea taolo ea boleng ho netefatsa hore tanka e 'ngoe le e' ngoe e fihlela litekanyetso tse phahameng ka ho fetisisa:
• Qetella tlhahlobo ea mahlakore bakeng sa kopano e nepahetseng
• Licheke tsa boleng ba welding ho latela litifikeiti tsa indasteri
• Liteko tsa khatello le ho lutla ho netefatsa ts'ebetso e bolokehileng le e tšepahalang-ea nako e telele
Kalafo ea Bokaholimo & Tšireletso ea Corrosion
Mehaho ea li-transformer tsa kantle e hloka khanyetso e phahameng ea kutu. Re fana ka litlhare tse ngata tse holim'a metsi ho lelefatsa bophelo ba litšebeletso libakeng tse thata:
• Ho chesa-dip galvanizing bakeng sa ho thibela kutu haholo
• Pente ea indasteri bakeng sa ho roala ho sireletsa
• Powder coating bakeng sa-e tšoarellang nako e telele le botle bo botle
Matla a rona a Tlhahiso ea Tanka ea Oli ea Transformer
- Seboka sa ho Etsa Litanka tsa Oli
- Mokhoa oa Tlhahiso ea Tanka ea Oli ea Transformer
- Litanka tsa oli tsa Transformer li felile
LBH
P: A na u ka etsa litanka tsa transformer ho latela litšoantšo tsa rona?
A: Ho joalo. Re sebetsa ka ho khetheha ho litanka tsa li-transformer tse ipapisitseng le litšoantšo tsa bareki le litlhaloso tsa tekheniki.
P: Re fumana khotheishene joang?
A: Re romelle feela litšoantšo tsa hau, litlhaloso, kapa litlhoko tsa mantlha, 'me sehlopha sa rona sa boenjiniere se tla arabela kapele.
P: Na u fana ka tšehetso ea tekheniki ka mor'a ho pepa?
A: Ho joalo. Sehlopha sa rona sa boenjiniere se fana ka ts'ehetso bakeng sa ho kenya, ho lokisa, le ho rarolla mathata ho netefatsa{1}}botšepehi ba nako e telele.
P: Na litanka li thehiloe molemong oa polokeho?
A: Ho joalo. Litanka tsohle tsa li-transformer tsa motlakase li entsoe ka likhetho tse kopaneng tsa fatše ho netefatsa polokeho ea motlakase nakong ea ts'ebetso.
P: Na litanka li ka sebetsana le lits'ebetso tsa kantle libakeng tse thata?
A: Ho joalo. Litanka tsa rona li etselitsoe maemo a ka ntle, tse nang le-liaparo tsa boleng bo holimo, tse matlafatsang, le ho tiisa hore li tšoarella nako e telele le ho sireletseha.
P: U fana ka likhetho life tsa tšireletso ea kutu?
A: We provide multiple corrosion protection methods: stainless steel, hot-dip galvanization, polyester powder coating, and polyurethane topcoats. Most options achieve >Lihora tse 1000 ho hanyetsa ho fafatsa letsoai.
P: Na litanka tsa hao tsa transfoma{0}ke bopaki ba ho dutla?
A: Ho joalo. Litanka tsohle li na le khatello e matla-e lekoa le ho chesetsoa ho sebelisoa mekhoa e tsoetseng pele ho netefatsa{2}}oli ea nako e telele{3}}e tiileng le bots'epehi ba sebopeho.
Li-Blogs tse Amanang

Fumana Qotsulo mabapi le Moralo oa Tanka ea Transformer
Jiangshan Scotech Electrical Co., Ltd ke e mong oa bahlahisi ba etelletseng pele le barekisi ba tanka ea transformer naheng ea China. Re u amohela ka mofuthu hore u reke -tanka ea transfoma e sebetsang hantle e rekisoang mona femeng ea rona. Haeba u na le potso mabapi le khotheishene kapa litšoantšo, ka kopo ikutloe u lokolohile ho re romella lengolo-tsoibila.