50 KVA Transformer ea Motlakase Ka Pole-2.4 * 7.2 / 0.12 * 0.24 KV|Canada 2025
Matla: 50kVA
Matla: 2.4 * 7.2-0.12 / 0.24kV
Tšobotsi: Dual{0}}voltage transformer e nang le IFD
Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba ka tšeptjoang ka ho fetisisa ba 50 kva motlakase transfoma ka pole{8}}2.4*7.2/0.12*0.24 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

50 kVA transformer ea motlakase palo - dual-voltage e nang le IFD bakeng sa phetisetso e tšepahalang ea mahaeng a Canada
01 Kakaretso
1.1 Lintlha tsa Bohloko ba Bareki
Marang-rang a Canada a atisang ho fana ka tlhahiso ea 120/240 V, ha a ntse a sebetsa ho pholletsa le mefuta e mengata ea motlakase, haholo-holo libakeng tsa mahaeng le tse fokolang{2}}. Ka hona, lits'ebeletso li tlas'a khatello ea ho sebelisa li-transformer tse ka ikamahanyang le litlhophiso tse fapaneng tsa phepelo ntle le ho rarahana ho ntseng ho eketseha.
Mathata a mantlha a kenyelletsa:
• Phihlello e fokolang libakeng tsa mahaeng, e hlokang botšepehi bo phahameng le tlhokomelo e fokolang
• Ho tsepamisa maikutlo ho eketsehileng holim'a ts'ireletso ea ts'ebetso, haholo-holo tšireletso ea liphoso ka hare
• Khatello ea thepa le thepa e bakoang ke meralo e le 'ngoe-ea li-voltage transformer
Hangata litharollo tsa khale li haelloa ke maemo a hlokahalang ho rarolla mathata ana, 'me sena se etsa hore mochini o nang le "voltage pole"{1}} o kenngoeng{1}o nang le ts'ireletso e kopaneng ea IFD e be mokhoa o sebetsang hantle le o sireletsehileng haholoanyane.
1.2 Likopo tse Tloaelehileng bakeng sa Marang-rang a Phatlalatso ea Canada
Transformer ena ea 50kVA Pole{1}}e kenngoeng ka motlakase e etselitsoe lisebelisoa tsa ho tsamaisa ka holimo tse fanang ka litšebeletso tsa 120/240 V naheng ea Canada. Tlhophiso ea eona e etsa hore e tšoanelehe ka ho khetheha bakeng sa:
• Lithapo tsa ho fepa ka holim'a metsi libakeng tsa mahaeng
• Libaka tsa bolulo le meroalo e bobebe ea khoebo
• Marang-rang a kabo ea lisebelisoa a hlokang hore CSA C2.2-06 e latele melao
The dual{{0}voltage primary design e lumella ho romelloa likarolong tse fapaneng tsa marang-rang ntle le liphetoho tsa sebopeho, ho ntlafatsa mokhoa oa ho feto-fetoha ha sistimi ha o ntse o boloka ts'ebetso e ts'oanang maemong a ts'ebetso ea kantle.
1.3 Tlhaloso ea Setsebi
Transformer ea motlakase ea 50kVA holima lipalo le leqephe la data
|
E fetisetsoa ho
Canada
|
|
Selemo
2025
|
|
Mofuta
Pole mounted transformer
|
|
Standard
CSA C2.2-06
|
|
Rated Power
50KVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
Motho a le mong
|
|
Mofuta oa ho Pholisa
ONA
|
|
Mokelikeli o thibelang metsi
Oli ea Liminerale
|
|
Voltage ea mantlha
2.4 * 7.2-0.12/0.24kV
|
|
Motlakase oa bobeli
120 / 240 V
|
|
Polarity
Keketso
|
|
Sehlopha sa Vector
Ii6
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
2.85%(±10%)
|
|
Katleho
E kholo ho feta kapa e lekana le 98.83%
|
|
Tlanya Changer
NLTC
|
|
Ha ho Tahlehelo ea Mojaro
139 W
|
|
Ho Lahleheloa ke Moroalo
693 W
|
|
Lisebelisoa
Dual{{0}voltage transformer e nang le IFD
|
1.4 Melemo ea Sehlahisoa
Transformer ena- e kentsoeng ka motlakase e fana ka mokhoa o tsitsitseng oa ho feto-fetoha le maemo, polokeho, le tšebeliso e ntle ea matla ka melemo e latelang:
• Litlhophiso tse peli- tsa motlakase oa mantlha
E fokotsa-litlhoko tsa sebaka sa sebaka le ho nolofatsa taolo ea thepa.
• Sesebediswa se Kopanetsweng sa Fuse sa ka Hare (IFD)
E fana ka ts'ireletso e ntlafalitsoeng ea liphoso tsa kahare, e ntlafatsa polokeho ea ts'ebetso le ho fokotsa kotsi ho lisebelisoa tse haufi.
• Matla a phahameng a matla
Ho sebetsa hantle ha Ho feta kapa ho lekana le 98.83% ho thusa ho theola-litšenyehelo tsa nako e telele tsa ts'ebetso.
• Moetso o ntlafetseng{0}}tahlehelo o tlase
Ha ho-tahlehelo ea mojaro: 139 W
Tahlehelo ea mojaro: 693 W
E netefatsa ts'ebetso e tsitsitseng ea mocheso le ts'ebetso e tšepahalang ea nako e telele-.
Ha e kopantsoe le ho pholisa ONAN le polane e tiileng-moetso o hloekisitsoeng, tharollo ena e kopana le litlhoko tse sebetsang tsa marang-rang a Canada a kabong.
1.5 Litšoantšo
50kVA transformer ea motlakase holim'a setšoantšo sa lipalo le nameplate
![]() |
![]() |
02 Likaroloana tsa Transformer Core
2.1 Ho tsubella

Ho hlophisoa ha li-coil: foil ea LV, mohala oa HV, motsoako oa koporo le aluminium. Foil e hasana hona joale, e tlosa mocheso. Mohala o kobeha, o lula o le insulated. Motsoako oa koporo-oa aluminium o otla katleho le theko e nepahetseng. E tšoarellang. E sebetsa literateng tsa litoropo, meleng ea mahaeng, eng kapa eng eo letsatsi le e lahlelang. E tšepahala, e tsitsitse, e etsa mosebetsi oa eona ntle le moferefere.
2.2 9KV HV Arrester
Ho kentsoe sets'oants'o sa motlakase o phahameng oa 9kV ho sireletsa transformer khahlanong le ho phahama ha lehalima le liketsahalo tse fetelletseng tsa nakoana tse atileng lits'ebetsong tsa phepelo e holimo. Ka ho fokotsa matla a ho phahama pele a fihla ka hare ho ts'ebetso ea ka hare, sets'oants'o se fokotsa khatello ea motlakase likarolong tsa bohlokoa 'me se ntlafatsa ho tšoarella ha motlakase ka kakaretso lits'ebetsong tsa marang-rang a mahaeng.

2.3 Sesebelisoa sa ka hare sa Fuse (IFD)

The Internal Fuse Device (IFD) e etselitsoe ho khaola transformer ka hare nakong ea boemo bo matla ba phoso. Mokhoa ona oa ts'ireletso o fokotsa kotsi ea ho phatloha ha tanka, o fokotsa tšusumetso ea phoso, hape o ntlafatsa polokeho ea basebetsi le sistimi. IFD e kopantsweng e dumellana le ditlhoko tsa tshireletso bakeng sa pole{2}}li-transformer tse phahamisitsoeng ho marangrang a phano a Canada.
2.4 Kopano ea ho Qetela
Mokhahlelong oa ho qetela oa kopano, likarolo tse sebetsang tsa transformer li phethiloe ka botlalo, 'me lithapo tsa mantlha le lifensetere li kopantsoe ka mokhoa o sireletsehileng,' me lithapo tsohle tsa ka hare li tlatsitsoe hantle ebile li hokahantsoe. Likarolo tsa ho chencha li kentsoe 'me li tsitsitse maemong, ho etsa kopano ea mantlha ea transformer e felileng.

03 FAQ - Lipotso tse atisang ho botsoa
P: "Dual-voltage primary configuration e khethiloe kapa e fetoloa joang?
K: Transformer e na le moetso oa mantlha-o nang le motlakase, o lumellang khetho ea motlakase ka likhokahano tse boletsoeng esale pele nakong ea ho kenya kapa ho kenya tšebetsong.
P: Na transformer ee e loketse lithapo tse telele tsa lijo tsa mahaeng?
A: Ho joalo. Ka impedance e ntlafalitsoeng (2.85% ± 10%) le ts'ebetso e phahameng, transformer e sebetsa ka ts'epo meleng e telele ea kabo ea libaka tsa mahaeng.
P: Na transformer e ka etsoa bakeng sa litlhoko tse khethehileng tsa tšebeliso?
A: Ho joalo. Karolo e le 'ngoe ea pole e phahamisitsoeng ea Transformer e ka etsoa ka mokhoa o ikhethileng hore e lumellane le litekanyetso tsa IEC, ANSI/IEEE, CSA, RUS, le NEMA, ka likhetho tse feto-fetohang bakeng sa litekanyetso, motlakase, maqhubu, mokhoa oa ho pholisa, impedance, sehlopha sa vector, thepa ea tanka, le lisebelisoa tse kang li-shuttering tsa lehalima le IFD.
04 Ho paka le ho tsamaisa
4.1 Ho paka


4.2 Ho tsamaisa thepa


Hot Tags: transformer ea motlakase holim'a palo, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
50 kVA Transformer Motlakase Pole-13.8 / 0.347 kV|Ca...
37.5 kVA Transformers Ka Thelefono Pole-34.5 / 0.12 ...
100 kVA Residential Transformer-13.8/0.12 * 0.24 kV|...
25 kVA Transformer Light Pole-13.8 / 0.24 kV|Guyana ...
167 kVA Pole Mounted Distribution Transformer-24.94/...
25 KVA Single Phase Pole Transformer-25/0.347 KV|Can...
Romela Inquiry