Hobaneng U Khetha Liphetoho tsa Mofuta o omileng oa SCOTECH
E sa keneleng mollo le e thibelang malakabe
Epoxy resin casting e kopana le litlhoko tsa ho kenya letsoho tsa Sehlopha sa F, ho fokotsa kotsi ea mollo.
Tšilafalo-Mahala le Tikoloho
Oli{{0}moetso oa mahala o felisa kotsi ea ho lutla ha oli 'me o lumellana le maemo a RoHS/REACH.
Multiple Security Authentication
Li-transformer- tsa mofuta o omileng li netefalitsoe ke UL, CE, le ISO9001, 'me moralo oa tsona oa mahala-o felisa kotsi ea ho lutla ha oli.
Flexible Customization
Customization e fumaneha ho ipapisitse le matla, boholo, sebopeho le litlhoko tse ling.
Tlhokomelo e Bohlale
E na le-mocheso oa nako ea sebele le li-interface tsa hona joale tsa ho beha leihlo, tse nolofalletsang ho beha leihlo ka thōko.
Tšehetso ea tekheniki
Re fana ka tataiso ea ho kenya le ts'ehetso ea tekheniki e hole ho fihlela libaka tse fapaneng le litlhoko tse ikhethang.
Mefuta ea Li-transformer tsa Mofuta o omileng oo re o Etsang
E etselitsoe maemo a thata a hlokang tšireletso e phahameng ea mollo le tlhokomelo e fokolang.
• Lekhalo la Matla:50 kVA ho fihlela ho 20 MVA
• Palo ea li-volts:Ho fihlela ho 35 kV
• Insulation:Epoxy Resin Cast
Tharollo{{0}e sebetsang hantle ea mofuta o omileng bakeng sa lits'ebetso tsa ka tlung le tsa khoebo.
• Lekhalo la Matla:100 kVA ho fihla ho 14.5 MVA
• Palo ea li-volts:Ho fihlela ho 35 kV
• Insulation:Vacuum Pressure Impregnation
E tšeptjoa ke Leading Industries Worldwide
Hlahloba merero ea rona ea cast resin transformerr - VPI & Resin Insulated Transformer Solutions. Ho sebeletsa indastering,
merero ea khoebo, le ea ts'ebeliso ho pholletsa le Asia, Middle East, Europe le Amerika Boroa.
Na U se U Loketse ho Hlalosa Transformer ea Mofuta oa Hau o omileng?
Arolelana motlakase oa hau, lintlha tsa matla, le tikoloho ea ho kenya.
Joaloka morekisi ea etellang pele oa mofuta o omileng, SCOTECH e tla u thusa ho khetha le ho hlophisa transformer e nepahetseng — ka botlalo.
e lumellana le litekanyetso tsa UL, CE, le IEC.
Lits'ebetso tse Tloaelehileng tsa Liphetoho tsa Rona tsa Mofuta o omileng

Indasteri Limela
Li-transformer tsa mofuta o omileng oa SCOTECH tse rekisoang li fana ka kabo ea matla e tsitsitseng le e sebetsang bakeng sa lifeme, mehala ea tlhahiso le lisebelisoa tse boima tsa indasteri.

Mehaho ea Khoebo
E loketse liofisi, litsi tsa mabenkele, le litsi tsa khoebo, e netefatsa hore -e fumaneha lerata le sireletsehileng le le tlase.

Merero ea Matla a Tsosolositsoeng
E loketse mapolasi a letsatsi, liteishene tsa motlakase oa moea, le lisebelisoa tsa motlakase tse tšoarellang, tse fanang ka matla a motlakase a tšepahalang le ho sebetsa hantle.

Meaho le Lisebelisoa
E ts'ehetsa liporo, boemafofane, litsi tsa ho hloekisa metsi, le marang-rang a masepala, ho fana ka matla a tsitsitseng le a sireletsehileng.

Litsi tsa Boitsebiso le Lisebelisoa tsa IT
E netefatsa lerata le tsitsitseng,{0}le tlase, le matla a sireletsehileng bakeng sa li-server le lisebelisoa tsa bohlokoa tsa IT.

Lipetlele le Litsi tsa Tlhokomelo ea Bophelo
E fana ka matla a sa sitisoeng, a ts'eptjoang bakeng sa lisebelisoa tsa bongaka tse hlokolosi le lits'ebetso tsa bohlokoa tsa tlhokomelo ea bophelo.
Mofuta o omileng oa Feme ea Transformer & Tiisetso ea Boleng
Joaloka moetsi le mofani oa thepa ea porofeshenale ea mofuta o omileng, SCOTECH e sebetsa setsing sa tlhahiso se kopaneng ka botlalo bakeng sa li-transformer tsa Cast Coil le VPI. Transformer e 'ngoe le e 'ngoe ea etsoa, ea lekoa, le ho netefatsoa ka-ka tlung ho netefatsa ts'ebetso e tšepahalang le ho latela maemo a machaba.
Flexible Custom Manufacturing
E khona ho hlahisa li-transformer tse ikhethileng tse ipapisitseng le voltage, matla le litlhoko tsa projeke.
Teko ea Fektheri Pele e Romeloa
Transformer e 'ngoe le e 'ngoe e bokelloa le ho lekoa sebakeng sa-ho netefatsa hore na motlakase o sebetsa joang.
Tshebeletso-e le 'ngoe
Re fana ka-tshebeletso e le 'ngoe, ho qala ka lipuisano, quotation, ho etsa thepa, ho instola, ho kenya tšebetsong, koetliso ho isa{1}}kamora litšebeletso tsa thekiso, ho fihlela litlhoko tsa projeke ea bareki ba rona.
Tlhahlobo e tiileng ea Boleng
Mekhoa e mengata ea tlhahlobo le liteko e sebelisoa pele ho tlisoa ho fihlela maemo a machaba.
Setsi sa rona sa Tlhahiso ea Transformer
Eba le liteko, boqapi le tlhokomelo ka mor'a sesebelisoa se seng le se seng sa phepelo ea mofuta o omileng.
- Fektheri ea Transformer ea Mofuta o omileng
- Teko ea VPI Transformer
- Teko ea Cast Resin Transformer
Setifikeiti le Tumellano ea Liphetoho tsa Mofuta o omileng oa SCOTECH
SCOTECH ke moetsi oa motlakase o tšeptjoang oa mofuta o omileng, o tlisang- Cast Coil ea boleng bo holimo le mofuta o omileng oa VPI
li-transformer. Lihlahisoa tsohle tsa rona ke CE, UL, le ISO tse netefalitsoeng, tse netefatsang ts'ebetso e tšepahalang, polokeho le ho latela melao.
ka maemo a machaba.
LBH
P: Na u fana ka tšehetso ea tekheniki le tataiso ea ho kenya?
A: Ho joalo. Baenjiniere ba rona ba nang le phihlelo ba fana ka litherisano tsa botekgeniki, tataiso ea ho kenya, le{1}tšehetso ea ka mor'a thekiso lefatšeng ka bophara ho netefatsa hore transformer ea hau e sebetsa ka botšepehi ho tloha letsatsing la pele.
P: Na li-transformer tsa SCOTECH li ka sebelisoa libakeng tse thata?
A: Ho joalo. Li-transformer tsa SCOTECH li etselitsoe mocheso o phahameng, mongobo o phahameng, indasteri le tikoloho ea khoebo. Li-insulation tse khethehileng le likhetho tsa ho pholisa lia fumaneha bakeng sa lits'ebetso tse hlokang.
P: Ke mefuta efe ea li-transformer tsa mofuta o omileng tse fumanehang?
A: Re fana ka li-transformer tsa mofuta o omileng ho tloha ho li-unit tsa 50 kVA ho isa ho 20MKV tsa mofuta o omileng oa li-transformer, tse loketseng meaho ea khoebo, lifeme le marang-rang a kabo ea motlakase.
P: U sebelisa sehlopha sefe sa insulation?
A: Joaloka mofani oa li-transformer tsa mofuta o omileng, re sebelisa lisebelisoa tsa ho kenya letsoho tsa A, E, B, F, le H, tse fanang ka ts'ebetso e babatsehang ea ho kenya mocheso oa mocheso le bophelo bo bolelele ba tšebeletso esita le tlas'a maemo a sa khaotseng a mojaro.
P: Li-transformer tsa mofuta o omileng li bolokehile hakae ha li bapisoa le li-transformer tsa oli?
K: Li-transformer tsa rona tsa mofuta o omileng ha li na oli-, 'me li etsa hore li se ke tsa chesa-ebile li baballa tikoloho. Li loketse libaka tse nang le litlhoko tse tiileng tsa tšireletso ea mollo.
Related Blogs for Dry Type Transformer

Fumana Qotsulo mabapi le Theko ea Transformer ea Mofuta o Omileng
Jiangshan Scotech Electrical Co., Ltd ke e mong oa bahlahisi ba etelletseng pele le barekisi ba mofuta o omileng oa transformer naheng ea China. Re u amohela ka mofuthu hore u reke -transformer e sebetsang hantle e rekisoang femeng ea rona. Haeba u na le potso mabapi le khotheishene kapa litšoantšo, ka kopo ikutloe u lokolohile ho re romella lengolo-tsoibila.



























