50 kVA Single Pole Mounted Transformer-13.8/0.347 kV|Canada 2025
Matla: 50 kVA
Matla: 13.8/0.347kV
Tšobotsi: e nang le mots'oari

Ha ho Tšabo ea Lehalima, Ha ho ho Khaoha ha Motlakase-24/7 Tšireletso ka Transformer ea Rona e Phahamisitsoeng!
01 Kakaretso
1.1 Tlhaloso ea Morero
Ka 2025, 50 kVA single-phase pole{3}}mounted transformer e ile ea isoa Canada hore e sebelisoe libakeng tsa mahaeng le -litoropong. Sebaka sena se sebeletsa lihlopha tse nyane tsa bolulo le meroalo ea mapolasi ea lehae kapa ea khoebo e tsamaisoang ke mohala o holimo oa 13.8 kV. E etselitsoe ho sebetsana le tlhokeho ea linako tsa selemo le maemo a sefefo khafetsa, transformer e netefatsa phepelo e tsitsitseng, e sebetsang hantle le maemong a thata.
E hahiloe ho maemo a CSA C2.2-06, yuniti e na le pholiso ea ONAN, lintlha tsa 13.8 kV / 0.347 kV, sehlopha sa li-vector tsa Ii6, le Additive polarity. E kenyelletsa mochine oa ho fetola lipompo tsa NLTC tse nang le mefuta e fapaneng ea ± 2 × 2.5% bakeng sa tokiso e nepahetseng ea motlakase. Ka aluminium windings, 2.3% impedance, le 98.35% e sebetsang hantle, e fana ka ts'ebetso e matla ka tahlehelo e tlaase le tlhokomelo e bonolo.
E behiloe holim'a palo e tloaelehileng ea kabo e nang le "cutout" ea mantlha e kopantsoeng, sets'oants'o sa surge, le sistimi e thehang fatše, transformer ena e fana ka tharollo e bolokehileng le e tenyetsehang ea kabo ea matla. E nepahetse bakeng sa motlakase oa mahaeng, libaka tsa mehala, le meroalo e menyenyane ea indasteri, e kopanya ho tšoarella, ho ts'epahala, le taolo e ntle ea motlakase ka moralo o le mong o kopaneng oa kantle.
1.2 Tlhaloso ea Setsebi
50 kVA pole mounted transformer specifications type le data sheet
|
E fetisetsoa ho
Canada
|
|
Selemo
2025
|
|
Mofuta
Pole mounted transformer
|
|
Standard
CSA C2.2-06
|
|
Rated Power
50 kVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
1
|
|
Polarity
Kekeletso
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
13.8 kV
|
|
Motlakase oa bobeli
0.347 kV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Angular displacement
Ii6
|
|
Tšitiso
2.3%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
0.135 kW
|
|
Ho Lahleheloa ke Moroalo
0.705 kW
|
1.3 Litšoantšo
50 kVA pole mounted transformer diagram to the size and size.
![]() |
![]() |
02 Tlhahiso
2.1 Konokono
Transformer ena e na le meralo e tsoetseng pele ea maqeba, moo mokokotlo o lulang o tsoa ho tloha-mohatsela o kenang{1}ka likhoele tse kolokileng tsa silicon ho etsa sekhechana se koalehileng sa makenete. Ha ho bapisoa le li-cores tse tloaelehileng tsa laminated, leqeba ha le fane ka{3}}tahlehelo e tlase, lerata le fokotsehileng, phallo e tšoanang ea phallo, le matla a matla a ho se tsitse.

2.2 Ho tsubella

Transformer ena e sebelisa theknoloji e tsoetseng pele ea matsoelintsoeke: lehlakore le tlase-voltage (LV) le sebelisa foil winding bakeng sa -mokhoa oa ho jara le ho felisa mocheso, e leng ho fokotsang tahlehelo ea hona joale ea eddy; athe lehlakore le phahameng-voltage (HV) le sebelisa mokhoa o nepahetseng oa ho tsamaisa terata ho netefatsa matla a insulation le botsitso ba motlakase. Moralo ona o kopantseng oa "foil-wound LV + wire-wound HV" o sebetsa hantle ka ho fetesisa, o sebetsa ka thata, o momahane, o sebetsa ka nako e khuts'oane-e leng ho etsang hore e be e loketseng bakeng sa ho batla lisebelisoa tse katiloeng ka ntle{8}}.
2.3 Tanka
Transformer ena e sebelisa tanka ea cylindrical e tiisitsoeng ka hermetically e entsoeng ka mokhoa o nepahetseng oa ho khumama. Tanka e entsoe ka tšepe e pholileng{{1}e phethiloeng, 'me tanka e bōpiloe ka mochini oa CNC o nang le seam e le 'ngoe feela e nepahetseng ea laser{2}}, e hlahlobiloeng ka thata ke X{3}}ray le liteko tsa ho lutla. Moralo oa cylindrical ha o fane feela ka botle bo kopaneng empa hape o fana ka matla a ikhethang a mochini le ho qhala mocheso, o nang le likanale tse tataisang tsa oli tsa kahare bakeng sa pholiso e sebetsang ea tlhaho. E na le meaho e meraro-ea layer anti{7}}anti-corrosion coat (primer + epoxy intermediate + polyurethane topcoat), e mamella maemo a thata joalo ka setlolo sa letsoai le pula ea asiti.

2.4 Kopano ea ho Qetela

1. Kopano e Phethahalang:Tsamaisa mapheo a HV/LV holim'a konokono ea laminated, ho etsa bonnete ba hore ho ba le tlhophiso e nepahetseng le tumello ea ho kenya letsoho.
2. Lihokelo tsa Motlakase:Maqhubu a hokela a lebisa ho li-changer tsa pompo, lihlahla le likarolo tse ling, 'me li lateloa ke ho tiisa le kalafo ea insulation.
3. Ho Omisa Likhoele:{1}}Beha karolo e sebetsang e kopane ka ontong e omisang ho tlosa mongobo le ho ntlafatsa ts'ebetso ea ho kenya letsoho.
4. Ho Kenya Tanka:Kenya karolo e omisitsoeng e sebetsang ka tanka, e tiise hore e be teng, 'me u tiise sekoahelo sa tanka.
5. Ho hlomamisa lisebelisoa:Kenya li-bushings, arrester, valve e fokotsang khatello.
6. Ho Tlatsa le ho Tiisa Oli:Vacuum-tlatsa oli e sireletsang, hlahloba boemo ba oli le ho tiisa ka mor'a ho lokisa, 'me u etse liteko tsa ho qetela hore u phethe.
03 Teko
|
Che. |
Ntho ea Teko |
Yuniti |
Melao ea ho Amohela |
Litekanyetso Tse Lekanyelitsoeng |
Qetello |
|
1 |
Litekanyo tsa ho hanyetsa |
/ |
/ |
/ |
Feta |
|
2 |
Liteko tsa Karolelano |
/ |
Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5% Letšoao la khokahano: Ii6 |
0.06~0.10 |
Feta |
|
3 |
Liteko tsa polarity |
/ |
Kekeletso |
Kekeletso |
Feta |
|
4 |
Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale |
% |
I0 :: fana ka boleng bo lekantsoeng(100%) |
0.24 |
Feta |
|
kW |
P0: fana ka boleng bo lekantsoeng(100%) |
0.1065 |
|||
|
% |
I0 :: fana ka boleng bo lekantsoeng(105%) |
0.24 |
|||
|
kW |
P0: fana ka boleng bo lekantsoeng(105%) |
0.1172 |
|||
|
/ |
mamello ea ho se lahleheloe ke moroalo ke +10% |
/ |
|||
|
5 |
Litahlehelo tsa meroalo, motlakase oa impedance, tahlehelo e felletseng le katleho |
/ |
T:85 likhato mamello ea impedance ke ± 15% mamello ea tahlehelo ea boima kaofela ke +6% |
/ |
Feta |
|
% |
Z%: boleng bo lekantsoeng |
2.28 |
|||
|
kW |
Pk: boleng bo lekantsoeng |
0.634 |
|||
|
kW |
Pt: boleng bo lekantsoeng |
0.7405 |
|||
|
% |
Katleho e seng ka tlase ho 98.84% |
99.01 |
|||
|
6 |
Teko ea Voltage e sebelisitsoeng |
/ |
LV: 10kV 60s HV:34kV 60s |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
7 |
Teko ea ho mamella Voltage e kentsoeng |
/ |
Matla a sebelisoang (KV):2 Ur |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
Nako:40 |
|||||
|
Hangata (HZ): 180 |
|||||
|
8 |
Tekanyo ea ho hanyetsa Insulation |
GΩ |
HV{{0}LV·to·Ground |
451 |
Feta |
|
LV-HV ho ea fatše |
489 |
||||
|
HV&LV ho ea fatše |
113 |
||||
|
9 |
Leakage Test |
/ |
Khatello e sebelisitsoeng: 20kPA |
Ha ho na leakage le che Tšenyo |
Feta |
|
Nako:12h |
|||||
|
10 |
Tlhahlobo ea oli |
kV |
Matla a Dielectric |
61.3 |
Feta |
|
mg/kg |
Mongobo |
10.6 |
|||
|
% |
Ntho ea ho senya |
0.091 |
|||
|
mg/kg |
Furan Analysis |
Ka tlase ho kapa ho lekana le 0.1 |
|||
|
/ |
Tlhahlobo ea Khase ea Chromatography |
/ |


04 Ho paka le ho Romela
4.1 Ho paka
Transformer e kentsoe ka har'a krete ea lehong e koetsoeng ka botlalo e entsoeng ka mongobo{{0}plywood ea plywood e sa keneleng mongobo, e nang le lintho tse kenngoeng ka foam tse tloaelehileng le{2}}masakaneng a thibelang ho sisinyeha ho etsa hore sesebelisoa se se ke sa sisinyeha nakong ea leeto. Bokantle bo tlositsoe ka vanishi e sa keneleng metsi 'me e matlafalitsoe ka marapo a tšepe, a kentsoeng ka litšepe tse boima- tse lihukung tsohle. Pele o paka, transformer e omisoa ka vacuum mme e tlatsitsoe ka nitrogen ea 0.02MPa. Matšoao a hlahelletseng a machaba a setsi sa matla a khoheli, "Keep Dry" le "This Side Up" a hlahisoa. E netefalitsoe ho latela litekanyetso tsa ISTA 3A, sephutheloana se mamella lipalangoang tsa litsela tsa 2000km le maemo a machaba a thepa ea leoatleng.

4.2 Ho tsamaisa thepa

Li-transformer li tla romelloa ka tlas'a maemo a CIF (Litšenyehelo, Inshorense, le Thepa), ho tloha boema-kepeng ba Ningbo ho ea Boema-kepeng ba Montreal. Thepa e tla romelloa ka thepa e kentsoeng leoatleng, ka mehato e sireletsehileng ea ho palamisa le ho itšireletsa (thibela{1}}ts'oenyeho, ho thibela mongobo-e thibelang ho bola, le ho thibela ho bola-le ho bola) ho netefatsa hore ho na le maeto a malelele{4}}a maoatle. Morekisi o tla hlophisa lipalangoang tsa leoatle le ho fana ka inshorense ea metsing (Likotsi Tsohle), e koahelang tahlehelo e ka bang teng ka lebaka la likotsi kapa likoluoa tsa tlhaho nakong ea lipalangoang. Ha a fihla Montreal, moreki o ikarabella bakeng sa tumello ea meetlo le lipalangoang tse ling tsa naha.
05 Tlhokomelo ea{1}}li-transformer tse palamisitsoeng
Ho hlokomela{0}li-transformer tse palamisitsoeng ha se feela taba ea ho tšoaea lethathamo. Ke ho netefatsa hore karolo e 'ngoe le e' ngoe e tsoela pele ho sebetsa ka mokhoa o sireletsehileng, ka katleho le ka nako e telele kamoo ho ka khonehang. Polokeho, botšepehi, le botsitso - kaofela li ipapisitse le lintlha tse nyane. Ka linako tse ling, lintlha tseo ba bang ba li hlokomolohang.
(1) Tlhahlobo ea Kamehla ea Pono
Mohato oa pele o lula o le bonolo - sheba feela. Ho skena ka potlako hangata ha ho bolele tlaleho feela. Lekola hore na ha ho na ho lutla ha oli, ho bola, kapa ho senyehile. Matheba a oli a ka fana ka maikutlo a tiiso e mpe; mafome a ka bolela hore tanka e felloa ke matla butle-butle. Ho lokisa tsena kapele-pele li hola ho ba mathata a maholo-ho boloka nako le lisebelisoa.
(2) Boemo ba Oli le Tlhahlobo ea Boleng
Oli ea Transformer ke bophelo ba eona. E pholile, e sireletsa, e sireletsa. Oli e tlase? Eo ke folakha e khubelu. Oli e lefifi kapa e koahetsoeng ke maru? Hape bothata. Phihlelo ea Scotech e bontša hore tlhahlobo ea oli e tloaelehileng, esita le e potlakileng, e thibela ho chesa haholo pele ho qala.
(3) Ho Hloekisa Oli
Joale, ka linako tse ling tlhahlobo ha ea lekana. Oli e ka 'na ea shebahala e le ntle empa e lahleheloa ke lintho tsa eona ha nako e ntse e feta - mongobo, likhase, likaroloana tse nyenyane li kena ka hare. Ke nako eo tlhoekiso e kenang. Vacuum dehydration, filtration, degassing… a bit technical, e, empa ho hlokahala. Potoloho e 'ngoe le e' ngoe e khutlisetsa matla a oli, e lelefatsa nako ea bophelo ea transformer.
(4) Fastening Connections
Liboutu tse hlephileng ha li utloahale li le monate, empa li baka mathata a sebele - arcing, libaka tsa mocheso, le ho hloleha ho sebetsa. Khokahano e 'ngoe le e' ngoe e bohlokoa: lihlahla, lipompo, libaka tsa motheo. Lihlopha tsa tlhokomelo ea Scotech lia tiisa, li hlahloba hape, 'me li tiisa hape ha ho hlokahala. Ke mosebetsi o khathatsang, empa ke sona se bolokang li-transformer li phela lilemo tse ngata.
(5) Ho hloekisa
Lerōle, marotholi a linonyana, esita le ho siea - lintho tse nyenyane tse thibelang ho phalla ha moea le ho tšoara mocheso. Ha nako e ntse e ea, radiator ha e khone ho hema. Kahoo, ho hloekisa ha se setlolo; ke karolo ea tsamaiso ea ho pholisa. Transformer e hloekileng e sebetsa ka mokhoa o pholileng, e nka nako e telele. E bonolo, empa

Hot Tags: Single Pole Mounted Transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
15 kVA Pole Mounted Transformer-24.94 / 0.12 * 0.24 ...
100 kVA Residential Transformer-13.8/0.12 * 0.24 kV|...
50 kVA Transformer Power Line-13.8/0.12 * 0.24 kV|Gu...
50 kVA Utility Pole Transformers-34.5 / 0.12 * 0.24 ...
25 kVA Transformer Light Pole-13.8 / 0.24 kV|Guyana ...
75 kVA Pole Mounted Transformer-7.97/0.12/0.24 kV|Ca...
Romela Inquiry