25 KVA Motlakase Pole Transformer-7.2 / 0.12 * 0.24 KV|Canada 2025

25 KVA Motlakase Pole Transformer-7.2 / 0.12 * 0.24 KV|Canada 2025

Naha ea thomello: Canada 2025
Matla: 25kVA
Matla: 7.2-0.12/0.24kV
Sebopeho: Tšireletso ea Dual Voltage & IFD
Romela Inquiry

Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba tšepahalang ba 25 kva motlakase pole transformer{7}}7.2/0.12*0.24 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

 

25 kVA electricity pole transformer

25 kVA motlakase pole transformer - motlakase o ka tšeptjoang oa mahaeng o nang le 9 kV HV Arrester bakeng sa tšireletso le polokeho ea nako e telele-

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

Toropo e nyane e lebopong la Atlantic Canada e ts'epa mehala ea kabo e holimo. Li-feeders li matha sebaka se selelele ho pholletsa le masimo a bulehileng le lebōpong la leoatle. Hangata sebaka sena se ba le lialuma lehlabula le moea o matla kapa leqhoa mariha. Matlo le likhoebo tse nyane li fumana-mohato o le mong oa 120/240 V motlakase ho tsoa ho li-pole transformer tse kentsoeng haufi le li-feeders.

Transformer ea 25 kVA e etselitsoe tikoloho ena. E na le motlakase o ka sehloohong oa 12,470 GRDY / 7,200 V le 120 / 240 V ea bobeli, e sebetsa ho 60 Hz, 'me e na le mapheo a aluminium, mokokotlo oa tšepe ea laminated, ONAN cooling, le NLTC e nang le ± 2 × 2.5% tap range. E sebetsa hantle haholo (E kholo ho feta kapa e lekana le 98.87%), e na le tšitiso ea 1.9% ±10%, 'me e kenyelletsa sets'oants'o sa 9 kV HV bakeng sa ts'ireletso ea ho buuoa. E sebelisetsoa ho fana ka matlo a seng makae kapa khoebo e nyenyane ka mokhoa o sireletsehileng le ka botšepehi.

Fana ka matlo a 3-6 kapa khoebo e nyane e haufi le tsela.

Ho fanyehoa lipalong tsa lepolanka tse nang le hardware e tloaelehileng.

Sebetsa libakeng tse nang le kotsi e kholo ea ho otloa ke lehalima le maqhubu a motlakase.

Hobaneng ha 9 kV HV Arrester e le Bohlokoa? Sets'oants'o sa 9 kV se boloka transformer e bolokehile ka ho khelosa kapele li-spikes tsa motlakase tse ts'oanang, joalo ka lehalima kapa li-switchings, ho ea fatše pele sepakapaka se ka senyeha.

Sena se bohlokoa haholo-holo libakeng tsa mahaeng le mabopong a leoatle, moo ts'ebetso e le 'ngoe e matla e ka phunyang mohatsela, ea senya mapheo, kapa ea theola oli ea transformer, e lebisang ho hloleheng le ho tima. Tekanyetso ea 9 kV e khethiloe ka hloko ho lumellana le motlakase oa tsamaiso, ho etsa bonnete ba hore motho ea ts'oereng o sebetsa pele transformer ka boeona e hatelloa.

 

 

 

1.2 Tlhaloso ea Setsebi

Tlhaloso ea 25kVA ea motlakase oa pole ea motlakase le leqephe la data

E fetisetsoa ho
Canada
Selemo
2025
Mofuta
Pole mounted transformer
Standard
CSA C2.2-06/C802.1-23
Rated Power
25KVA
Khafetsa
60HZ
Mokhahlelo
Motho a le mong
Mofuta oa ho Pholisa
ONA
Mokelikeli o thibelang metsi
Oli ea Liminerale
Voltage ea mantlha
12470GRDY/7200
Motlakase oa bobeli
120/240 V
Polarity
Keketso
Sehlopha sa Vector
Ii6
Lintho Tse Hlahang
Aluminium
Tšitiso
1,9%(±10%)
Katleho
E kholo ho feta kapa e lekana le 98.87%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
85 W
Loss Loss ka Rated Voltage
254 W
Lisebelisoa
Motšoantšisi oa 9kV HV

 

1.3 Litšoantšo

25kVA sets'oants'o sa motlakase oa poleiti ea motlakase le nameplate

25kVA electricity pole transformer drawing 25kVA electricity pole transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

25kVA electricity pole transformer iron core

Transformer e na le mokokotlo oa leqeba o entsoeng ka lishiti tse tšesaane tsa tšepe. E thusa matla a khoheli ho tsamaea habonolo lipakeng tsa mapheo a mantlha le a bobeli, ho fokotsa tahlehelo ea matla. Mokotla o matla ebile o kopane, o boloka motlakase o tsitsitse, o theola mocheso le lerata, 'me o etsa hore transformer e tšepahale letsatsi le leng le le leng.

 

2.2 Ho tsubella

E etselitsoe ts'ebetso e tsitsitseng, transfoma ena e palamisa LV ka terata ea HV. Koporo e nka hona joale, aluminium e fokotsa boima. Ba sebetsa mmoho. Mocheso o lula o laoloa. Litahlehelo li lula li le tlase. Meroalo ea fetoha, boemo ba leholimo boa fetoha, empa bo ntse bo sebetsa. E bonolo, e sebetsa hantle, ke mosebetsi ea khutsitseng oa -kabong e phahamisitsoeng.

25kVA electricity pole transformer coils

 

2.3 9KV HV Arrester

25kVA electricity pole transformer HV arrester

Sets'oants'o sa eona sa 9 kV HV, se hoketsoeng ho tloha sehlahleng sa HV ho ea fatše, se sireletsa transformer ka ho khelosa lehalima ka potlako kapa ho chencha maqhubu pele ho ts'oaroa kapa matsoeli a senyeha. Ka motlakase o tsoelang pele oa ho sebetsa oa 7.65 kV le motlakase o setseng o ka tlase ho 30 kV, o lumellana le motlakase oa tsamaiso ha o sebetsana le maqhubu a fihlang ho 100 kA. Phokotso e fokolang e fokolang (<10 pC) and 308 mm creepage distance ensure safe, reliable operation in wet or coastal conditions.

 

2.4 Kopano ea ho Qetela

Ka mor'a hore re behe li-core le li-coil ka tanka ea tšepe e tiisitsoeng, yuniti kaofela e kena ka har'a welding e hlokolosi le e thibelang kutu{0}e le hore e khone ho sebetsana le boemo ba leholimo ka ntle, lebōpong la leoatle ka lilemo tse ngata. Pele le ka mor'a ho e tlatsa ka oli ea liminerale, re sebelisa vacuum e felletseng-mokhoa oa ho omisa ho ntša mongobo ofe kapa ofe kapa moea o koetsoeng{3}}mohato ona o matlafatsa mohatsela le ho boloka karolo e tsoang ho tsoa e le tlase. Ha tanka e tlatsitsoe 'me sistimi ea eona ea ho futhumatsa ea ONAN e se e lokile, transformer e tla tsoa komporong ea ho qetela e hahiloeng bakeng sa ts'ebeletso e telele, e tšepahalang{{5}e phahamisitsoeng ka lipalo.

electricity pole transformer active part

 

 

03 Ho etsa liteko

25 kVA electricity pole transformer testing-1
25 kVA electricity pole transformer testing-2

 

 

04 Ho paka le ho tsamaisa

4.1 Ho paka

25 kVA electricity pole transformer packing-1
25 kVA electricity pole transformer packing-2

 

4.2 Ho tsamaisa thepa

25 kVA electricity pole transformer shipping-1
25 kVA electricity pole transformer shipping-2

 

 

05 Transformer ea Pole ea Motlakase: Kamoo Li Sebetsang Kateng

Electricity Pole Transformer

Pole{{0}mounted transformer e sebelisa electromagnetic induction ho theola{1}motlakase o matla ho fihla boemong bo loketseng malapa le likhoebo tse nyane. Ka hare, e na le matsoelintsoeke a mabeli-ea mantlha le a bobeli{4}a pota-potiloeng ke makenete:
• Mohaho oa mantlha o hokela-netweke ea phallo ea motlakase e phahameng.
• Maqhubu a bobeli a hokela ho -lithapo tsa motlakase tse tsamaisang 120 V kapa 240 V meahong.
Voltage e fokotsehile ho ea ka karo-karolelano ea li-turnings pakeng tsa li-winding tsa mantlha le tsa bobeli, ho fana ka motlakase o bolokehileng, o ka sebelisoang bakeng sa lisebelisoa tsa letsatsi le letsatsi.

 

 

Hot Tags: motlakase pole transformer, moetsi, mofani oa thepa, theko, litšenyehelo