15 kVA Pole Mounted Transformer-24.94 / 0.12 * 0.24 kV|Canada 2024
Matla: 15kVA
Matla: 24.94/0.24kV
Tšobotsi: e nang le OCTC

Moo boenjiniere ba maemo a holimo bo kopanang le ts'ebetso e tšepahalang-{1}}palo e le 'ngoe{2}}li-transformer tse kentsoeng.
01 Kakaretso
1.1 Semelo sa Morero
The 15 KVA single phase pole mounted transformer e ile ea isoa Canada ka 2024. Matla a lekantsoeng a pole mounted transformer ke 15 KVA e nang le pholiso ea ONAN, motlakase o ka sehloohong ke 24.94 KV, motlakase oa bobeli ke 0.12 / 0.24 KV. E entsoe ho latela CSA C2.2-06 e tloaelehileng.
Linaheng tse tsoetseng pele ka bophirimela le Asia Boroa-bochabela, Amerika Leboea le Boroa, palo e kholo ea{0}}li-phase transformer li sebelisoa e le li-transformer tse tsamaisang thepa. Ho marangrang a ajoang a motlakase, single-mohato oa transfoma e le sesebelisoa sa phepelo e na le melemo e mengata, e ka fokotsa bolelele ba-mohala oa ho ajoa ha motlakase, ea fokotsa tahlehelo ea mehala, ea ntlafatsa boleng ba phepelo ea motlakase. Moralo oa sebopeho sa coil core o sebetsa hantle haholo le ho boloka matla, transformer e tšoauoa ka tšebeliso ea mehala e emisitsoeng, boholo bo nyane, matsete a manyane a litšebeletso, ho fokotsa{5}} radius ea phepelo ea motlakase e tlase, e ka fokotsa tahlehelo ea mohala ho feta 60%. Transformer e amohela sebopeho se tiisitsoeng ka botlalo, bokhoni bo matla ba ho jara, ho ts'epaha haholo ts'ebetsong e tsoelang pele le tlhokomelo e bonolo. E loketse likhoele tsa motlakase tsa mahaeng, libaka tse lithabeng tse hole, metse e qalikaneng, tlhahiso ea temo, mabone le tšebeliso ea motlakase, hape e ka sebelisoa bakeng sa -ho boloka phetoho ea litšiea tsa kabo ea litšiea liporong le likhoeleng tsa motlakase litoropong.
Re etsa bonnete ba hore karolo e 'ngoe le e 'ngoe ea rona e tlisitsoeng e entse tlhahlobo e matla ea ho amoheloa. Re fana ka-tšebeletso e le 'ngoe ho tloha ho boeletsi, ho qotsa, ho etsa thepa, ho kenya tšebetsong, ho fana ka lithupelo ho isa litšebeletsong tsa ka mor'a thekiso, lihlahisoa tsa rona li se li sebetsa literekeng tse fetang 50 lefatšeng. Re ikemiselitse ho ba morekisi ea tšepahalang ka ho fetisisa hammoho le molekane oa hau ea hloahloa khoebong!
1.2 Tlhaloso ea Setsebi
15 KVA karolo e le 'ngoe ea poleiti e kentsoeng sefetoleli le leqephe la data
|
E fetisetsoa ho
Canada
|
|
Selemo
2024
|
|
Mofuta
Pole Mounted Transformer
|
|
Standard
CSA C2.2-06
|
|
Rated Power
15KVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
1
|
|
Polarity
Kekeletso
|
|
Mofuta oa ho Pholisa
ONA
|
|
Mokelikeli o thibelang metsi
Oli ea Liminerale
|
|
Voltage ea mantlha
24.94KV
|
|
Motlakase oa bobeli
0.12/0.24KV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
1.5%
|
|
Tlanya Changer
OLTC
|
|
Tlanya Range
±2*2.5%
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
|
Litlhaloso
N/A
|
1.3 Litšoantšo
15 KVA pole mounted transformer diagram pent and size.
|
|
|
02 Tlhahiso
2.1 Konokono
Mokotla o amohela mokhoa oa mantlha oa ho kobeha o otlolohileng, o nang le ts'ebetso e phahameng ea motlakase, ho hlasimolla ho fokolang, ho se{0}}tahlehelo e tlase, lerata le tlase, boholo bo nyane, boima bo bobebe, ts'ireletso ea tikoloho le ho boloka matla, tlhahiso ea mantlha e bonolo, ts'epo ea boleng bo holimo, boholo bo nyane ba ponahalo le melemo e meng, e ka fihlela litlhoko tsa bareki ba boholo bofe kapa bofe.

2.2 Ho tsubella

Foil winding transformer ke mofuta o mocha oa transformer e omeletseng ha e bapisoa le transformer ea khale, 'me matsoelintsoeke a eona a tlase-ea motlakase ha a tsoetsoe ke terata ea koporo e sephara, empa a thateloa ka bophara ba pampiri ea foil ea aluminiamo haufi le bophahamo ba joko e ka holimo le e tlase. Foil winding transformer e na le melemo e mengata, joalo ka boima bo bobebe, thepa e nyane, e matla e khuts'oane-e hanyetsanang le potoloho le tlhahiso e ntle haholo.
2.3 Tanka
Khamphani ea rona e sebelisa{{0}litšepe tsa boleng bo holimo e le thepa e tala bakeng sa tlhahiso ea litanka tsa mafura, 'me e sebelisa mochini oa haeteroliki kapa lisebelisoa tse ling ho koba, ho seha le ho hatella poleiti ea tšepe hore e be sebopehong se lakatsehang sa tanka ea mafura. Butt likarolo 'me u etse welding e sirelelitsoeng ka khase kapa lits'ebetso tse ling tsa welding ho netefatsa ho tiea le matla a sebopeho sa tanka. Litiiso tsohle li tiisitsoe pheletsong; Likarolo tsa tšepe tse ka hare le ka ntle ho lebokose li pota-potiloe ho tlosa moriri, 'me seam le tiiso ea weld li lekoa ka makhetlo a mararo (fluorescence, khatello e ntle, teko e mpe ea leakage); Pente e entsoe ho latela litlhoko tse tloaelehileng tsa -anti rust.

2.4 Kopano ea ho Qetela

Mokhoa oa ho kopanya -mohato o le mong o phahamisitsoeng oa transfoma
1. Kenya mokokotlo oa tšepe setulong sa mantlha sa tšepe. Hoa lokela ho hlokomeloa hore ha hoa lokela ho ba le likhutlo tse bohale holim'a setulo ho qoba ho khaola thepa ea ho pata.
2. Kenya lisebelisoa tsa ho pata mokokotlong oa tšepe. Mosebetsi oa thepa ea ho kenya letsoho ke ho arola coil ea ho kenya letsoho ho tloha ho coil e hlahisoang le ho thibela lipotoloho tse khutšoanyane pakeng tsa maqhubu.
3. Koaela khoele ho pota-pota lisebelisoa tsa ho pata. Ela hloko tatellano ea matsoelintsoeke, e lokelang ho etsoa ho latela litlhoko tsa moralo. Ka nako e ts'oanang, ho boetse hoa hlokahala ho ela hloko hore na ho phalla ha coil ho nepahetse, ho seng joalo ho tla ama katleho ea mosebetsi oa transformer.
4. Kopanya boto ea terminal. The terminal board e ka ba poso ea terata kapa terminal. Khetha terminal ho latela maemo a nnete. Ho phaella moo, hoa hlokahala ho ela hloko boholo ba poso ea terata kapa terminal, ho bapisa coil.
5. Hokela khoele letlapeng la terminal. Ha u kopanya li-coil le liboto tsa li-terminal, sebelisa lisebelisoa tse nepahetseng tsa ho pata ho tiisa hore ho na le khokahanyo e ka tšeptjoang le e tsitsitseng.
6. Bokella khetla. Mosebetsi o ka sehloohong oa ntlo ke ho sireletsa coil le ho arola ka mokhoa o sireletsehileng ho kenya letsoho le ho tsoa. Ha ho bokana, hoa hlokahala ho ela hloko boholo le thepa ea khetla, hape u nahane ka litlhoko tsa ho senya mocheso le tšireletso.
03 Ho etsa liteko
Hangata li-transformer- tse nang le karolo e le 'ngoe li hloka ho etsa liteko tse latelang:
Teko ea insulation: ho kenyelletsa tlhahlobo ea ho hanyetsa insulation, tlhahlobo ea "dielectric loss factor" le tlhahlobo ea ho ntša karolo e itseng ho netefatsa bots'epehi ba sistimi ea insulation.
Teko ea Voltage: Kenya motlakase o itseng lipakeng tsa lead ya motlakase o phahameng le lead ea low voltage ho bona hore na sekontiri sa transformer se ka mamella matla a phahameng.
Teko ea Resistance: Lekola khanyetso ea sistimi e tsoelipanang le ea ho theola fatše ho netefatsa hore e fihlela litlhoko tsa moralo.
Che-tlhahlobo ea mojaro: Lekola tšebetso ea motlakase oa transformer tlas'a-maemo a ho roala, ho kenyeletsoa ho se be-tahlehelo ea mojaro le{3}}mosebetsi oa hona joale.
Teko ea mojaro: leka ts'ebetso ea transformer tlas'a mojaro o lekantsoeng ho netefatsa hore e ka sebetsa ka botsitso le ka ts'epo.
Teko ea ho phahama ha mocheso: tlas'a maemo a boima a lekantsoeng, leka ho phahama ha mocheso oa transformer ho etsa bonnete ba hore e ke ke ea senyeha ka ho feteletseng.
Teko ea overload: Lekola matla a mangata a transformer ho netefatsa hore e ke ke ea senyeha molemong oa mojaro o feteletseng oa nakoana.
Tlhahlobo ea potoloho e khutšoanyane: Lekola bokhoni ba potoloho e khutšoanyane ea transformer ho netefatsa hore e ke ke ea senyeha tabeng ea potoloho e khutšoanyane.


04 Ho paka le ho Romela


05 Sebaka le Kakaretso
Re leboha khahleho ea hau ho -phase pole{1}}mounted transformer e le 'ngoe! Ka melemo ea eona ea ho sebetsa hantle haholo, ho ts'epahala, le ho boloka matla, sehlahisoa sena se sebelisoa haholo lits'ebetsong tsa kabo ea motlakase, se kopanang le litlhoko tsa motlakase maemong a fapaneng. Re ikemiselitse ho fana ka -lihlahisoa le litšebeletso tsa boleng bo holimo ho netefatsa ts'ebetso e bolokehileng le e tsitsitseng ea lisebelisoa tsa hau tsa motlakase. Re labalabela ho sebetsa le uena ho ntšetsa pele nts'etsopele ea indasteri ea matla hammoho!

Hot Tags: 15 kva pole mounted transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
167 kVA Power Pole Transformer-13.8 / 0.347 kV|Canad...
75 kVA Transformer On Power Lines-12.4 * 24.94 / 0.1...
50 kVA Pole Mounted Transformers-34.5 / 0.48 kV|Cana...
50 kVA Transformer On Power Pole-7.97/0.12/0.24 kV|C...
50 kVA Transformer Utility Pole-13.8 / 0.24 kV|Guyan...
167 kVA Pole Mounted Distribution Transformer-24.94/...
Romela Inquiry