167 KVA Transformer Motlakase Pole-13.8/0.24/0.12 KV|Guyana 2025
Matla: 75 kVA
Matla: 13.8-0.12/0.24kV
Tšobotsi: e nang le matsoelintsoeke a koporo
Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba tšepahalang ba 167 kva transformer electro pole{7}}13.8/0.24/0.12 kv|guyana 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

E nyane holim'a palo, e kholo ka ts'ebetso - Tšepa transformer e kentsoeng ka karolo e le 'ngoe bakeng sa phano e tšepahalang ea{1}}mohato.
01 Kakaretso
1.1 Tlhaloso ea Morero
167 kVAmotlakase oa motlakase oa motlakasee ile ea isoa Guyana ka 2025. Matla a lekantsoeng a transformer ke 167 kVA e nang le pholiso ea ONAN. Motlakase o phahameng ke 13.8 kV le ± 2 * 2.5% tapping range (NLTC), matla a tlaase ke 0.12 / 0.24 kV, ba thehile sehlopha sa vector sa Ii0.
167 kVA,-mohato o le mong-transformer e kentsoeng{2}}e emela tharollo e ka tšeptjoang haholo le e sebetsang hantle bakeng sa marang-rang a phanoang ka holimo, e etselitsoeng ho theola matla a phahameng a motlakase a 13.8 kV ho ea ho -voltage split{5}}mohato o tlase oa 120/240 V.SIE E entsoe/E hlophisitsoe ka botlalo le 20 C.SIEE E entsoe ka C57 C. le litekanyetso tse amanang le IEEE C57, transfoma ena e sebetsa e le karolo ea bohlokoa bakeng sa kabo ea motlakase libakeng tsa bolulo, merero ea ho kenyetsa motlakase libakeng tsa mahaeng, litsi tsa khoebo tse bobebe, le lits'ebetso tsa temo, e fana ka{11}kabo ea motlakase e tsitsitseng le ea boleng bo holimo e nang le tahlehelo e fokolang ea ts'ebetso.
Pole ea motlakase ea transformer e na le oli e matla-e qoelitsoeng,{1}}mohaho o ipholisitseng-o nang le ONAN (Oil Natural Air Natural) o tsidifatsang, o nolofalletsang ts'ebetso e tsoelang pele e rehelletsoeng ka tlas'a maemo a thata a ka ntle{2}. Tanka ea eona ea tšepe e tiisitsoeng e kenngoe ka maemo a leholimo-melaeletso e sa tsitsang, lihlahla tsa porcelain tse phahameng-li-voltage tse phahameng,{6}}matlapa a tlase,{7}}ho tima{7}}load tap changer, sesebediswa sa ho imolla khatello, le tanka{8}litokiso tse behiloeng fatše, tse netefatsang hore li tšoarella nako e telele{9} Transformer e ts'ehetsa litlhophiso tsa sehlopha sa li-vector tsa Ii0 'me e hokahantsoe le subtractive polarity, e tsamaellanang le IEEE C57.12.70 theminal marking standards for single{13}} unit unit mme e thusa ho tsamaisana ka ho otloloha le ho hokahana le ligridi tse tloaelehileng tsa ts'ebeliso.
Motsoako oa eona oa mats'oafo-moqapi o phahamisitsoeng, tekhenoloji e tsoetseng pele-ea tahlehelo ea mantlha, e thehileng subtractive polarity, hammoho le lisebelisoa tse phahameng tsa -mokhoa oa ho mamella ho potoloha, e e etsa indasteri{3}}tharollo e ratoang bakeng sa phepelo ea motlakase ea ho qetela{4}maele metseng ea litoropo le libakeng tse hole.
1.2 Tlhaloso ea Setsebi
167 kVA mofuta oa lintlha tsa motlakase oa motlakase oa motlakase le leqephe la data
|
E fetisetsoa ho
Guyana
|
|
Selemo
2025
|
|
Mofuta
Pole mounted transformer
|
|
Standard
IEEE & ANSI C57.12.00
|
|
Rated Power
167 kVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
1
|
|
Polarity
Subtractive
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
13.8 kV
|
|
Motlakase oa bobeli
0.12/0.24 kV
|
|
Lintho Tse Hlahang
Koporo
|
|
Angular displacement
Ii0
|
|
Tšitiso
2%
|
|
Tlanya Changer
±2*2.5%(kakaretso ea mefuta=10%)
|
|
Ha ho Tahlehelo ea Mojaro
0.379 kW
|
|
Ho Lahleheloa ke Moroalo
1.36 kW
|
|
Tahlehelo e felletseng
1.739 kW
|
|
Tšusumetso ea mabone a mantlha (HV)
95kV
|
|
Basic lighting impulse (LV)
30kV
|
1.3 Litšoantšo
167 kVA sets'oants'o sa sets'oants'o sa poleiti ea motlakase le boholo.
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa

Theko e entsoe ka tšepe ea silicon e phahameng{{0}, e batang{1}e kolobisitsoeng, ea lijo-thollo- e nang le moralo o kopaneng oa lirope, e leng ho fokotsang tahlehelo ea maikutlo le tahlehelo ea hona joale. Koko kaofela e kentsoe molemong oa ho fokotsa phallo e salletseng, e bakang ho se be le -moroalo o tlase haholo le ho se lahleheloe ke-moroalo bakeng sa ts'ebetso e ntlafetseng. The clamping system e netefatsa botsitso nakong ea lipalangoang le ts'ebetso ea nako e telele-.
2.2 Ho tsubella
Mapheo a HV le a LV a sebelisa-oksijene e hloekileng{1}ea holimo{1}likhondara tsa koporo tsa mahala (aluminiamo ka boikhethelo) tse nang le sebopeho sa geometry. Interlayer le interturn insulation li sebelisa-pampiri e nang le maemo a phahameng a mocheso kapa thepa ea Nomex®, e fana ka bokhoni bo phahameng ba ho mamella{4} potoloho. Moralo o netefatsa kabo ea tšimo ea motlakase e ts'oanang; boemo ba ho tsoa ka mokhoa o itseng bo bolokiloe ka tlase ho 1/3 ea moeli o tloaelehileng. Sebaka sa ho thepha se kopana le ± 2×2.5% kapa litlhoko tsa tloaelo.

2.3 Tanka

Tanka e entsoe ka moaho o tiisitsoeng ka ho feletseng, e cheselitsoe{0}ka lipoleiti tsa tšepe tsa boleng bo holimo, 'me e ka lekoa ho lutla le khatello ea maikutlo. Bokaholimo bo hloekisoa ka pente ea kantle e thibelang kutu (C5-M grade bakeng sa tikoloho e matla), e loketseng ho pepesehela khanya ea letsatsi, pula, lehloa, le letsoai nako e telele. Sekoahelo se entsoe ka lithebe tsa pula, 'me li-angles tsa bushing li ntlafalitsoe bakeng sa ho kenya lipalo le ho hokahanya ha cable. Mapheo a radiator kapa mabota a masenke a etselitsoe ho nyoloha ha mocheso hantle ka ho potoloha ha oli ea tlhaho (ONAN cooling).
2.4 Kopano ea ho Qetela
Kopano ea ho qetela e etsoa ho latela maemo a IEEE, ho kenyeletsoa core-ho etsa stacking, ente ea oli ea vacuum, ho hloekisa le ho kenya lisebelisoa. Sebopeho ka kakaretso se kopane, 'me se na le sebopeho se utloahalang sa-voltage le tlase{3}}li-voltage bushings le tap changer, tse tsamaellanang le palo e ka holimo{4}}ea boholo bo kentsoeng le litlhoko tsa matla. Polarity, sehlopha sa li-vector le khokahanyo e matsoelintsoeke li lekantsoe ho netefatsa ts'ebetso e tsitsitseng le e tšepahalang ea ts'ebetso.

03 Teko
Liteko tsohle tse tloaelehileng li phethoa ho latelaIEEE C57.12.90-2021, 'me lintho tsohle li loketse:
- Ho hanyetsa moea, karo-karolelano ea motlakase le tlhahlobo ea polarity: ea tšoanelehang
- Ha ho{{0}tahlehelo ea mojaro le hajoale: 0.366 kW, 0.47%, 3.294 A
- Tahlehelo ea mojaro (85 degrees ), -ho se sebetse hantle ha potoloho le ho sebetsa hantle: 1.257 kW, 2.36%, 99.23%
- Teko ea motlakase e sebelisitsoeng: HV 34 kV/60 s, LV 10 kV/60 s, ha ho putlama ha motlakase
- Teko ea ho mamella voltage e kentsoeng: 150 Hz, 48 s, 2Ur, ha ho ho putlama ha motlakase
- Ho hanyetsa insulation, ho tiisa le tlhahlobo ea dielectric ea oli: bohle ba tšoaneleha


04 Ho paka le ho Romela
4.1 Ho paka
- Pakete ea mantlha:Transformer e tiisitsoe ka mokotleng oa foil oa aluminium tlas'a vacuum, ebe e kenngoa ka har'a kreiti ea lepolanka.
- Ho hlahloba boemo ba pente:Pele o paka, pente e hlahlojoa bakeng sa mengoallo leha e le efe kapa liphello; touch{0}up penta e sebelisoa ha ho hlokahala.
- Litokomane:Litokomane tsa pampiri (bukana ea litaelo, tlaleho ea teko, joalo-joalo) li behiloe ka har'a kreiti.
- Pente e setseng:Lekotikoti le lenyenyane la pente ea spare le kenyelelitsoe. Sebaka sa eona ka hare ho crate se ngotsoe ka foto e fanoeng ho moreki.
- Moqapi oa Pallet/Motheo:Setsi sa lepolanka sa crate se entsoe ka 140 mm high skids (maoto) ho lumella forklift ho kena ho tloha mahlakoreng a mabeli a fapaneng.
4.2 Ho tsamaisa thepa
Lisebelisoa le lipalangoang tse tloaelehileng lia amoheloa, tse loketseng lipalangoang tsa fatše le leoatleng. Ts'ebetso eohle e tsitsitse ebile e sirelelitsoe ho qoba ts'enyo ea ho falla le ho thulana. Sehlahisoa se -hlahlobuoa hape pele se romelloa ho netefatsa hore transformer e fihla e ntse e le teng, 'me e ka kenngoa le ho sebelisoa ka kotloloho ka mor'a hore e fihle.
05 Sebaka le Kakaretso
Single{0}phase pole{1}transformer ea rona e kopantseng moralo o kopaneng o kenngoeng habonolo le ts'ebetso e tšepahalang. E hahiloe ka{{3}ka tšepe ea boleng bo phahameng ea silicon le mohaho o tiisitsoeng ka ho feletseng, e fana ka tahlehelo e fokolang-ea meroalo, boima bo bongata, le tlhokomelo e telele-bophelo ba tšebeletso ea mahala libakeng tse thata tsa kantle. E loketse bodulo, temo le mejaro e menyenyane ya kgwebo, e fana ka tharollo e bolokehileng le ya theko{7}e sebetsang hantle.Khetha transformer ea ronabakeng sa boleng bo netefalitsoeng le tšehetso e inehetseng. Ikopanye le sehlopha sa rona sa thekiso bakeng sa lintlha kapa thuso ea ho reka.

Hot Tags: transformer motlakase pole, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
50 kVA Transformer Motlakase Pole-13.8 / 0.347 kV|Ca...
50 kVA Utility Pole Transformers-34.5 / 0.12 * 0.24 ...
167 kVA Pole Distribution Transformer-14.4/0.6 kV|Ca...
37.5 kVA Pole Mounted Transformer-2.4 / 0.12 kV|Cana...
25 KVA Pole Mounted Transformer-13.8/0.12/0.24 KV|Ca...
50 KVA Pole Transformers-14.4/0.12 * 0.24 KV|Canada ...
Romela Inquiry