50 KVA Pole Transformers-14.4/0.12 * 0.24 KV|Canada 2025

50 KVA Pole Transformers-14.4/0.12 * 0.24 KV|Canada 2025

Naha ea thomello: Canada2025
Matla: 50kVA
Matla: 14.4-0.12/0.24kV
Sebopeho: Tšireletso ea Dual Voltage & IFD
Romela Inquiry

Jiangshan Scotech Electrical Co., Ltd ke e 'ngoe ea baetsi le barekisi ba tšepahalang ba 50 kva pole transformer-14.4/0.12*0.24 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

 

50 kVA pole transformers

50 kVA pole transformer e nang le Dual Voltage & IFD tshireletso - e sebetsang hantle, e matla{2}}matla a matle bakeng sa marangrang a lebopo le a mahaeng

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

The 50 kVA single-phase pole{2}}mounted transformer e etselitsoe ho ajoa ka mokhoa o tšepahalang libakeng tse lebopong la leoatle le mahaeng. E sebetsa ho 60 Hz mme e ts'ehetsa li-voltage tse peli tsa mantlha (24,940 GRDY kapa 14,400 V), e lumella ho kenya lisebelisoa tse fapaneng ha e ntse e fana ka tlhahiso ea 120/240 V ho ea bobeli. Yuniti e sebelisa li-windings tsa aluminium le tšepe ea laminated core, e nang le mohatsela oa ONAN le oli{12}}ka tanka e koetsoeng nako e telele kantle. E fihlella katleho e kholo ho feta kapa e lekanang le 99.04%, e se nang-tahlehelo ea mojaro 130 W, tahlehelo ea mojaro 492 W, le ho se sebetse 2.16% (±10%). A Non-Load Tap Changer (NLTC) ±2 × 2.5% e boloka motlakase o tsitsitse ha ho ntse ho fetoloa meroalo.

Transformer e boetse e na le 9 kV high-voltage arrester ho kokobetsa lehalima le ho chencha maqhubu fatše pele a ka hatella mohatsela kapa mapheo a senyang - e hlokahalang bakeng sa lisebelisoa tse hlasetsoeng ke lifefo, sefafatsi sa letsoai le moea/qhoa mariha. Karolo e 'meli{{4} ea motlakase e lumella lisebelisoa ho boloka mefuta e fokolang ea li-transformer e le teng le ho kenya liyuniti kapele nakong ea ho tima kapa ho ntlafatsa. Ka lintlha tsa 50 kVA, e ka thusa malapa le likhoebo tse ngata ho feta 25 kVA transformer, e leng se etsang hore e be tharollo e tšepahalang, e tlaase{8} ea tlhokomelo ea marang-rang a lebopong le libakeng tsa mahaeng.

 

 

 

1.2 Tlhaloso ea Setsebi

Tlhaloso ea 50kVA pole transformers le leqephe la data

E fetisetsoa ho
Canada
Selemo
2025
Mofuta
Pole mounted transformer
Standard
CSA C2.2-06/C802.1-23
Rated Power
50KVA
Khafetsa
60HZ
Mokhahlelo
Motho a le mong
Mofuta oa ho Pholisa
ONA
Mokelikeli o thibelang metsi
Oli ea Liminerale
Voltage ea mantlha
24940GRDY/14400 V
Motlakase oa bobeli
120 / 240 V
Sehlopha sa Vector
Ii6
Polarity
Keketso
Lintho Tse Hlahang
Aluminium
Tšitiso
2.16%(±10%)
Katleho
E kholo ho feta kapa e lekana le 99.04%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
130 W
Loss Loss ka Rated Voltage
492 W
Lisebelisoa
Motšoantšisi oa 9kV HV

 

1.3 Litšoantšo

50kVA e pentiloeng ka poleiti ea poleiti le lebitso

50 kVA pole transformers drawing 50 kVA pole transformers nameplate

 

 

Moralo o Ikemetseng bakeng sa Maemo a Leholimo a Lebopo

Kaha sebaka sa ho kenya se sebakeng se lebopong la leoatle{{0}ka moea o mongobo, pula e nang khafetsa, le letsoai moeeng-re ile ra fetela ka nģ'ane ho mokhoa o itseng oa ho etsa lintlafatso tse seng kae:

 

1. Likoahelo tse Sireletsang{1}Tl

 

Re ile ra tsoela pele ho beha likoahelo tse sireletsang holim'a-li-voltage bushings-haholo-holo ho boloka tšireletso e thabile ebile e tsitsitse. Ua tseba, tikolohong e mongobo, e nang le lipula, ka linako tse ling e le metsi feela, ho koaheloa ka mokhoa o hlakileng ke ho batla mathata. Likoahelo tsee? Ha e le hantle ba e sireletsa mongobo, moeeng o letsoai o lebōpong la leoatle, linthong tsohle tse nyenyane tse ka thatafatsang bophelo bakeng sa transformer.

High-Voltage Bushing Protective Covers
 
High-Voltage Bushing Protective Covers drawing

2. 9 KV HV Arrester

Ebe ho na le sebatli sa 9 kV HV. E nyane, ee, empa ke taba e kholo ha ho phahama hoo ha motlakase ho otlang-maholiotsoana, ho fetoha, kapa maemo a leholimo a lebopong a leoatle. E teng ho ba tšoara, ho emisa li-flashovers, 'me ha e le hantle ho thibela tsamaiso ho tsoa ka letsatsi le lebe.

9 KV HV Arrester

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

50 kVA pole transformers iron core

Mokotla oa leqeba o etselitsoe ho sebelisoa ka ntle. Moralo oa eona o hlophisitsoeng o hanana le ho thothomela mme o boloka transformer e tsitsitse lipalong. Ha e fokotse-tahlehelo ea thepa, e sebetsa hantle ho li-feeders tse telele, 'me e khona ho sebetsana le moea, leqhoa le maemo a mang a leholimo, e fa mahae le likhoebo tse nyenyane motlakase o tšepahalang.

 

2.2 Ho tsubella

50 kVA pole transformers copper winding
50 kVA pole transformers iron and coil

Pole{{0}transformer ena e sebedisang-mohatla o tlase wa foil le mohatla{2}o phahameng wa terata, koporo le aluminium di kopantswe. Foil ea LV e boloka impedance e le tlase. Mocheso o ata ka ho lekana. HV terata ea tenyetseha, e sebetsana le liphetoho tsa mojaro. Koporo-motsoako oa aluminium{8}}e leka-lekanya katleho le litšenyehelo. E ka tšeptjoa, e tšoarella, e lumellana le li-grids tse nyane, khoebo ea bolulo kapa e bobebe, letsatsi le letsatsi.

 

 

03 Ho etsa liteko

50 kVA pole transformers testing-1
50 kVA pole transformers testing-2

 

 

04 Ho paka le ho tsamaisa

4.1 Ho paka

50 kVA pole transformers waiting for packing
50 kVA pole transformers in box

 

4.2 Ho tsamaisa thepa

50 kVA pole transformers shipping-1
50 kVA pole transformers shipping-2

 

 

05 FAQ

50 kVA pole transformers on the pole line

Q1: Na ho bolokehile ho kenya transformer libakeng tse mongobo kapa tse lebōpong la leoatle?

E, ka kakaretso ho bolokehile. Empa, libaka tse lebopong la leoatle-mongobo, letsoai moeeng, ka linako tse ling le le metsi ebile le le mongobo-li ka ba thata ho transformer. Ke ka hona re khothaletsang meralo e thibelang mongobo-e kang-masepala a matla a phahameng, a sa jeng{6}}lisebelisoa tse sa senyeheng, le motheo o tiileng. E thusa ho thibela mathata a insulation. E boloka lintho li tsamaea nako e telele. Tlhahlobo e potlakileng hona joale e tšoara mathata esale pele.

Q2: Na transformer e ka chesa haholo?

E ka khona. Haholo-holo haeba meroalo e phahame, kapa e ntse e sebetsa ka linako tsohle, kapa moea o sa tsamaee hantle. U hloka saese e nepahetseng pele. Oa pholisa? E bohlokoa haholo. Thempereichara ea oli kapa moea o tsoelipanang-li hlokomele. 'Me u nke transformer e nang le tekanyo e nepahetseng ea ho phahama ha mocheso bakeng sa mojaro oa hau o lebelletsoeng. Ho chesa nako e telele haholo, ho kenella ka hare ho lilemo ka potlako, ho theoha ha katleho, kotsi ea ho hlōleha e phahama.

Q3: Na sets'oants'o sa lehalima sea hlokahala?

E, ka matla. Esita le maqhubu a manyenyane, lehalima, li-switches spikes{1}} lia etsahala. Ntle le sets'oants'o sa ts'ebetso, ho kenya letsoho ho ka hloleha, li-flashovers li ka etsahala, bophelo ba transformer bo fokotseha. Sesebelisoa se bonolo, empa se etsa phapang e kholo. Maholiotsoana a lebopong la leoatle kapa marang-rang a sa tsitsang-ho tšoaroa ke khotso ea kelello.

Q4: Transformer e lokela ho hlokomeloa hangata hakae?

Bonyane hang ka selemo. Liteko tsa motlakase-liteko tsa ho thiba insulation, matsoelintsoeke, ho hlahloba karo-karolelano. Ho theola-etsa bonnete ba hore ha e tsitse, ha e na matla a fokolang. Insulation-batla mapetsong, kutu, mongobo. Oli-liyuniti tse qoelitsoeng? Tlhahlobo ea boleng ba oli, DGA, mongobo, acidity. Ka linako tse ling hangata, haeba mojaro o le boima kapa tikoloho e le thata. E boloka e matha, e qoba lintho tse makatsang.

 

 

Hot Tags: li-pole transformer, moetsi, mofani oa thepa, theko, litšenyehelo