25 KVA Pole Mounted Transformer-13.8/0.12/0.24 KV|Canada 2025

25 KVA Pole Mounted Transformer-13.8/0.12/0.24 KV|Canada 2025

Naha: Canada 2025
Matla: 25 kVA
Matla: 13.8-0.12/0.24kV
Tšobotsi: e nang le mookameli oa surge arrester
Romela Inquiry

Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba tšepahalang ba 25 kva pole mounted transformer{7}}13.8/0.12/0.24 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

 

25 kVA pole mounted transformer

Hlōla Sebaka, Fana ka Matla. The Adaptive Pole Mounted Transformer.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

25 kVA single phase pole mounted transformer e ile ea isoa Canada ka 2025. Matla a lekantsoeng a transformer ke 25 kVA e nang le pholiso ea ONAN. Motlakase o phahameng ke 13.8 kV le ± 2 * 2.5% tapping range (NLTC), matla a tlaase ke 0.12 / 0.24 kV, ba thehile sehlopha sa vector sa Ii6.

Ena ke 125kV BIL Pole Mounted Transformer e ka tšeptjoang haholo e etselitsoeng tikoloho e boima. Boemo ba eona bo ikhethang ba 125kV Basic Impulse Insulation Level bo fana ka indasteri-ts'ireletso e etellang pele khahlano le maqhubu a fetang nako e telele, ho etsa hore e lokele libaka tse tloaelehileng tsa lehalima{4}, libaka tse lebopong la leoatle, le libaka tse ling tse nang le litlhoko tse thata tsa ts'ireletso ea leqhubu. Karolo ena e na le mochini o matlafalitsoeng oa ho kenya oli-mohaho oa pampiri le moaho o tiisitsoeng ka mokhoa o tiisitsoeng, o netefatsang botsitso ba nako e telele-ea mokhoa oa ka hare oa dielectric le ho thusa ho lokisoa{8}} mahala. Ho feta moo, moralo oa eona o matla oa mochini le taolo e nepahetseng ea mocheso o netefatsa ts'ebetso e tšoarellang le e ts'epahalang tlas'a maemo a leholimo a mabe le meroalo e feto-fetohang. Transformer ena e sebetsa e le karolo ea mantlha bakeng sa ho matlafatsa botsitso ba marang-rang a kabo ea motlakase litoropong, lirapeng tsa mahae, lirapeng tsa boikhathollo tsa indasteri, le libakeng tsa ho kopanya matla a ka nchafatsoang. E fokotsa haholo kotsi ea ho hloleha ha lehalima{12}}ka lebaka la ho hloleha ha lehalima le litšenyehelo tsa ts'ebetso, ho fana ka phepelo ea motlakase e tsoelang pele le e tsitsitseng ho-basebelisi.

 

 

 

1.2 Tlhaloso ea Setsebi

25 kVA pole mounted transformer specifications type le data sheet

E fetisetsoa ho
Canada
Selemo
2025
Mofuta
Pole mounted transformer
Standard
CSA C2.2-06
Rated Power
25 kVA
Khafetsa
60HZ
Mokhahlelo
1
Polarity
Keketso
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
13.8 kV
Motlakase oa bobeli
0.12/0.24 kV
Lintho Tse Hlahang
Aluminium
Angular displacement
Ii6
Tšitiso
2.1%
Tlanya Changer
N/A
Ha ho Tahlehelo ea Mojaro
0.05 kW
Ho Lahleheloa ke Moroalo
0.365 kW

 

1.3 Litšoantšo

25 kVA pole mounted transformer diagram to the size and size.

25 kVA pole mounted transformer diagram 25 kVA pole mounted transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

25 kVA pole mounted transformer core

SCOTECH's pole - transformer mounted e nka premium amorphous alloy core, e entsoeng ka li-ultra - tšesaane tse tšesaane tsa makenete tse nang le sebopeho sa athomo se sa sebetseng hantle. Sesebediswa sena sa mantlha se fana ka tahlehelo e kgolo ya - e tlase haholo-e tlase haholo ho feta ya silicon cores e tlwaelehileng-ha e ntse e netefatsa hore e kgona ho kenella ka matla bakeng sa phetolo ya matla. Moetso oa eona o momahaneng, o bobebe ha o nolofatse lipoleiti feela - empa hape o matlafatsa ho senyehe ha kutu le botsitso ba ts'ebetso, e leng se etsang hore e be se loketseng bakeng sa marangrang a phano ea litoropo le mahaeng.

 

2.2 Tanka

SCOTECH's pole- transformer mounted e na le tanka e tiisitsoeng e entsoeng ka-tšepe e bonolo ea boleng bo holimo, e felileng ka 'mala o moputsoa o khanyang (Nomoro 70, Munsell notation 5BG7.0/0.4) bakeng sa botle bo sa fetoheng le ho mamella tikoloho. Mohaho o tiisitsoeng ka mokhoa o matla oa 580*660*1050 mm, 'me o sireletsa likarolo tsa ka hare ho mongobo, lerōle le litšila tse ka ntle, e netefatsa{10}}tšebetso ea nako e telele libakeng tsa phepelo ea litoropo le mahaeng.

25 kVA pole mounted transformer tank

 

2.3 Mookameli oa Motšoantšisi

surge arrester boss

Transformer ena{{0}e palamisitsoeng e na le mookameli ea kopantseng oa surge arrester, e etselitsoeng ho hlongoa ka mokhoa o sireletsehileng le ka nepo oa litšitiso tsa ho buuoa. E hlophisitsoe ka bots'epehi bo matla 'me e tsamaellana le litlhophiso tse tloaelehileng tsa sets'oants'o, mookameli enoa o fana ka ts'ehetso e ts'epahalang ha a ntse a thusa ho kenya tšebetsong-ntle ho mathata. Moralo oa eona o ntlafalitsoeng o netefatsa phapamiso e sebetsang ea li-overvoltages tsa nakoana, ho sireletsa likarolo tsa mantlha tsa transformer khahlano le ts'ebetso ea motlakase le ho ntlafatsa ts'ireletso ea grid ka kakaretso.

 

2.4 HV Terminal

Pole-transformer e palamisitsoeng e na le Litheminale tsa HV tse tšepahalang, tse nang le theminale ea H1 (4-tsela, mofuta oa clamp) bakeng sa likhokahano tsa kantle tse tenyetsehang le tse sireletsehileng, athe theminale ea H2 eona e hokahantsoe le tanka ka mofuta oa bolt-e tiileng. Moralo ona o ntlafalitsoeng oa terminal o netefatsa phetisetso ea matla e tsitsitseng, e nolofatsa lithapo tsa marang-rang, le ho matlafatsa matla a mochini, ho fana ka ts'ebetso e ts'oanang le ts'ireletso ea ts'ebetso lits'ebetsong tsa marang-rang.

HV Terminal

 

2.5 Ho beha fatše

25 kVA pole mounted transformer grounding

The pole{{0}transformer mounted e na le tsamaiso e felletseng ya ho thea fatshe, ho kenyeletswa le motheo o tiileng wa ho thea le ho thehwa ha tanka, o tlatliswang ke terapo e tshepehang le stainless steel{1}}hole spade-mofuta oa litheminale tsa fatše. Moralo ona o kopantseng o tiisa hore ho fediswa hantle ha maqhubu le ditefiso tse sa fetoheng, o fokotsa dikotsi tsa motlakase, mme o matlafatsa tshireletso ya tshebetso, athe theminale e tšoarellang e etsa hore ho be le dikgokelo tse bolokehileng,{4}}ntle le mathata a ho kenngwa ha marangrang a phano.

 

2.6 Sesebelisoa sa ho Pholosa Khatello

Transformer e na le sesebelisoa se matla sa ho imolla khatello, se etselitsoeng ho itokolla ka bohona khatello e feteletseng ea kahare e bakoang ke maemo a sa tloaelehang a ts'ebetso (mohlala, ho chesa haholo kapa arcing). Karolo ena ea bohlokoa ea polokeho e thibela ho senyeha kapa ho senyeha ha tanka, ho sireletsa likarolo tsa ka hare tsa transformer ha ho ntse ho netefatsa botšepehi ba ts'ebetso. Ka ts'ebetso e potlakileng{{4}e sebetsang ka thata le kaho e tšoarellang, e ntlafatsa polokeho le ts'epahalo lits'ebetsong tsa marang-rang litoropong le mahaeng.

Pressure Relief Device

 

2.7 Che-Excitation Tap Changer

No-Excitation Tap Changer

SCOTECH's pole-mounted transformer e na le{1}}excitation tap changer e tšoarellang, e etselitsoeng-taolo ea motlakase e matlafalitsoeng ho ikamahanya le ho feto-fetoha ha grid. E fana ka maemo a nepahetseng a lipompo, kaho e matla, le ts'ebetso e bonolo{{4}ea basebelisi, e thusa ho lokisa motlakase ka nepo-ntle le ho matlafatsa transformer, ho netefatsa polokeho ea ts'ebetso le bots'epehi ba sebopeho. E lumellana le litekanyetso tsa indasteri, karolo ena e fana ka ts'ebetso e tšepahalang, e thusang ho boloka boleng bo tsitsitseng ba phepelo ea motlakase ho pholletsa le marang-rang a kabo ea litoropo le mahaeng.

 

 

03 Ho etsa liteko

SCOTECH's pole-transformer e palamisitsoeng e etsa liteko tse matla tse thibelang ho fetoha ha motlakase khokahanyong ka 'ngoe, netefatso ea polarity, ha ho{1}}tahlehelo ea mojaro le litekanyo tse monate tsa hajoale ka 105% ea motlakase, tahlehelo ea mojaro le liteko tsa ho se sebetse ka maemo a hona joale le a voltage, hammoho le liteko tsa ho mamella voltage tse kentsoeng le tse kentsoeng{3} le leak tanka ea leak{3} Litlhahlobo tsena tse felletseng li netefatsa ho latela maemo a indasteri, li netefatsa ts'ebetso ea motlakase le bots'epehi ba sebopeho, 'me li netefatsa ts'ebetso e tšepahalang, e bolokehileng ho marang-rang a kabo.

25 kVA pole mounted transformer testing
25 kVA pole mounted transformer test

 

 

04 Ho paka le ho Romela

25 kVA pole mounted transformer packing
25 kVA pole mounted transformer shipping

 

 

05 Sebaka le Kakaretso

SCOTECH's pole-transformer mounted e kopanya likarolo tsa premium-ho tloha tlase{2}}tahlehelo ea amorphous alloy core le hermetically sealed mild steel tanka ho ea ho litheminale tse tiileng tsa HV, comprehensive grounding system, le likarolo tse ts'epahalang tsa ts'ireletso joalo ka sesebelisoa sa ho imolla khatello le surge arrester boss{3}ll E etselitsoe ts'ebetso e nepahetseng, e tšoarellang le ho e kenya habonolo, e fana ka kabo ea motlakase e tsitsitseng, e bolokehileng ho marang-rang a litoropo le a mahaeng, e kenyelletsang boitlamo ba SCOTECH ho boleng, boqapi le ts'ebetso e ts'eptjoang bakeng sa lits'ebetso tsa grid ea bohlokoa.

25 kVA pole mounted transformer supplier

Hot Tags: 25 kVA pole mounted transformer, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry