37.5 kVA Pole Mounted Transformer-2.4 / 0.12 kV|Canada 2025
Matla: 37.5 kVA
Matla: 2.4-0.12 / 0.24 kV
Tšobotsi: ha e na{0}}circuit tap changer

Fokotsa Tahlehelo, Eketsa Sephetho - Li-Transformer tse Mounted tse Smart Pole!
01 Kakaretso
1.1 Tlhaloso ea Morero
37.5 kVA single phase pole mounted transformer e ile ea isoa Canada ka 2025. Matla a lekantsoeng a transformer ke 37.5 kVA e nang le pholiso ea ONAN. Motlakase o ka sehloohong ke 2.4 kV o nang le ± 2 * 2.5% ho pata mefuta e mengata (NLTC), motlakase oa bobeli ke 0.12 / 0.24 kV, ba thehile sehlopha sa vector sa Ii6.
37.5kVA single-phase pole-transformer e behiloeng e etselitsoe ho ajoa ha motlakase ka tsela e sebetsang hantle le e tenyetsehang lits'ebetsong tsa kantle, e nang le{3}}voltage (HV) bushing) le lihlahla tse tharo tse tlase-voltage (LV) tse nang le 4-matheminale a 4{6}}a mekoti{9} bakeng sa likhokahano tse phahameng{7}} bakeng sa likhokahano tse phahameng{7}. Lehlakore la HV le kenyelletsa{11}}circuit tap changer (±2.5% adjustment range), e lumellang taolo ea motlakase ha e felloa ke{12}}matla, athe tokomane ea -multitap LV e ts'ehetsa kabo ea thepa e ngata. E hahiloe ka insusuite e matla le e momahaneng,{15}}mohaho o ka tjamisoang, yuniti ena e loketse ho kenya motlakase libakeng tsa mahaeng, mabone a literata, le{17}}tšebeliso e nyane ea liindasteri, e fanang ka tahlehelo e tlase le ts'ebetso e ts'epahalang tlas'a maemo a tloaelehileng a marang-rang. Ts'ebetso e nepahetseng e hloka litokiso tsa lipompo tse se nang matla le tlhokomelo ea kamehla ea lihlahla le li-terminals.
1.2 Tlhaloso ea Setsebi
37.5 kVA pole mounted transformer specifications type le data sheet
|
E fetisetsoa ho
Canada
|
|
Selemo
2025
|
|
Mofuta
Pole mounted transformer
|
|
Standard
CSA C2.2-06
|
|
Rated Power
37.5 kVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
1
|
|
Polarity
Kekeletso
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
2.4 kV
|
|
Motlakase oa bobeli
0.12/0.24 kV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Angular displacement
Ii6
|
|
Tšitiso
2.7%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
0.078 kW
|
|
Ho Lahleheloa ke Moroalo
0.720 kW
|
|
Katleho
98.73%
|
1.3 Litšoantšo
37.5 kVA poling mounted transformer diagram to the size and size.
![]() |
![]() |
02 Tlhahiso
2.1 Konokono
Leqeba la silicon core ka har'a-mohato o le mong-li-transformer tse kanngoeng li sebelisa-mabele a grade{3}a silika a holimo, a nang le moaho o sa tsitsang le ho se rate ha makenete a tlase. Moralo ona ha o fokotse-tahlehelo ea mojaro le lerata la ts'ebetso ha o ntse o fumana katleho e fetang 98%. The stepped-sebopeho sa lamination se ntlafatsa kabo ea matla a khoheli, e etsa hore e be e loketseng bakeng sa ho batla lits'ebetso tsa kabo ea holimo.

2.2 Ho tsubella

The transformer coil in single-pase pole-transformer mounted e na le likarolo tse ngata tsa insulated flat/round conductor tsa koporo, tse kopantseng{2}}le lisebelisoa tsa dielectric tse phahameng (mohlala, Nomex kapa DMD). Moralo ona o tiisa hore mocheso o fela, ho tiea ho hoholo, le{6}}mohaho o mokhuts'oane oa potoloho, athe bokhoni bo ntlafetseng ba interlayer bo hatella ho sotha ha harmonic.
2.3 Tanka
Litanka tsa oli tse kopantsoeng li entsoe ka tšepe e tšoarellang, e etselitsoeng ho mamella maemo a ka ntle ha e ntse e fana ka pholileng e sebetsang le ho kenya letsoho bakeng sa likarolo tse ka hare. Tanka e tlatsitsoe ka oli e sireletsang e sebetsang e le setsi se phodileng le sa dielectric. Li-brackets tse ntseng li kenngoa li kenyelelitsoe bakeng sa ho kenngoa ka mokhoa o sireletsehileng lipalong tsa lisebelisoa.

2.4 Kopano ea ho Qetela

1. Kopano e Phethahalang:Tsamaisa mapheo a HV/LV holim'a konokono ea laminated, ho etsa bonnete ba hore ho ba le tlhophiso e nepahetseng le bots'epehi.
2. Lihokelo tsa Motlakase:Ho hokela matsoelintsoeke ho lebisa ho chencheng ea pompo, lihlahla le likarolo tse ling, ebe o sireletsa le ho kenya manonyeletso.
3. Ho Omisa Likhoele:{1}}Beha karolo e sebetsang e kopaneng (konokono + windings) ka ontong e omisang bakeng sa ho futhumatsa vacuum ho tlosa mongobo.
4. Ho Kenya Tanka:Phahamisa karolo e omisitsoeng e sebetsang ka tankeng, e behe ka mokhoa o sireletsehileng, 'me u netefatse hore ho na le metsi a nepahetseng maboteng a tanka.
5. Ho hlomamisa lisebelisoa:Kenya lihlahla, valve e fokotsang khatello le lisebelisoa tse ling, ebe u hlahloba ho lutla.
6. Ho Tlatsa Oli le ho Lokisa:Vacuum-tlatsa oli e sireletsang, degas, 'me u lumelle ho tsitsa pele u hlahloba maemo a oli le matla a dielectric.
03 Teko
|
Che. |
Ntho ea Teko |
Qetello |
|
|
1 |
Litekanyo tsa ho hanyetsa |
Feta |
![]() |
|
2 |
Liteko tsa Karolelano |
Feta |
|
|
3 |
Liteko tsa polarity |
Feta |
|
| 4 | Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale |
Feta |
|
| 5 | Litahlehelo tsa meroalo, motlakase oa impedance, tahlehelo e felletseng le katleho |
Feta |
|
| 6 | Teko ea Voltage e sebelisitsoeng |
Feta |
|
| 7 | Teko ea ho mamella Voltage e kentsoeng |
Feta |
|
| 8 | Tekanyo ea ho hanyetsa Insulation |
Feta |
|
| 9 | Leakage Test |
Feta |
|
| 10 | Tlhahlobo ea oli | Feta |
04 Ho paka le ho Romela
4.1 Ho paka
Ho etsa bonnete ba hore ho na le lipalangoang le polokelo e bolokehileng,-transformer e palamisitsoeng e pakiloe ka har'a mabokose a lehong. Karolo e qala ka ho hloekisoa le ho hlahlojoa ho netefatsa hore ha ho na masalla a oli kapa tšenyo, 'me likarolo tse hlahelletseng (mohlala, lihlahla, li-gauge) li phuthetsoe ka foam kapa pubble, 'me 'mele oohle o koaheloa ke mongobo{4}ka pampiri kapa filimi ea polasetiki. E ntan'o tiisoa holim'a phalete ea lepolanka e tiisitsoeng ka likhoele. Kreiti, e entsoeng ka lepolanka le teteaneng la 15-20mm, e na le lithapo tse ka hare ho thibela ho sisinyeha, likhutlo tse tiisitsoeng tse nang le masaka a tšepe, le lesela le ka hare le sa keneleng metsi. Li-labels tse kang "Fragile," "Keep Dry," le "This Side Up" li khomaretsoe, ha lenane la ho paka, litlaleho tsa liteko le buka ea litaelo li koaletsoe ka mokotleng o sa keneleng metsi. Nakong ea ho kenya thepa, lithapo le lisebelisoa tsa ho khabisoa li sebelisoa ho itšireletsa khahlanong le lintho tse tšosang nakong ea{11}}ea maeto a malelele.

4.2 Ho tsamaisa thepa

Tlas'a lipehelo tsa CIF,-li-transformer tse phahamisitsoeng li tla isoa boema-kepeng ba Montreal. Morekisi o na le boikarabello ba ho hlophisa thepa ea leoatleng, ho lefella litšenyehelo tsohle ho kenyeletsoa le litefiso tsa inshorense le tsa thepa ho fihlela thepa e fihla boema-kepe. Li-transformer li tlameha ho kenngoa ka har'a mabokose a sireletsang boemo ba leholimo le ho ts'oha{3}}mekhatlo e sa tsitsang ho mamella mathata a ka bang teng le maemo a tikoloho nakong ea leeto. Litokomane tse nepahetseng, joalo ka sekoloto sa thepa, invoice ea khoebo, le setifikeiti sa inshorense, li tla fanoa ho netefatsa hore ho na le tumello e ntle ea moetlo Montreal.
05 Sebaka le Kakaretso
Pole-e kentsoeng transformer ke tharollo e tšepahalang le e sebetsang bakeng sa kabo ea motlakase e arolelanoeng, e etselitsoeng ho mamella maemo a thata a tikoloho ha e ntse e netefatsa taolo e tsitsitseng ea motlakase. Ka kaho e matla, ho kenya habonolo, le litlhoko tse tlase tsa tlhokomelo, ke khetho e nepahetseng bakeng sa marang-rang a ts'ebeliso, motlakase oa mahaeng le lits'ebetso tsa indasteri. E tšehelitsoe ke maemo a thata a boleng le ts'ebetso e netefalitsoeng, li-transformer tsa rona li fana ka nako e telele{3}}ea tšoarellang le ts'ebetso e sebetsang hantle. Ikopanye le rona kajeno ho fumana tharollo e phethahetseng ea kabo ea matla bakeng sa litlhoko tsa hau.

Hot Tags: 37.5 kva pole mounted transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
100 kVA Telephone Pole Transformer-34.5 / 0.24 kV|US...
167 kVA Cooper Pad Mounted Transformer-13.8/0.24 kV|...
50 kVA Transformer On Power Pole-7.97/0.12/0.24 kV|C...
50 kVA Single Pole Mounted Transformer-13.8/0.347 kV...
50 kVA Transformer Utility Pole-13.8 / 0.24 kV|Guyan...
75 kVA Overhead Transformer-24.94 / 0.347 kV|Canada ...
Romela Inquiry