50kva Pole Mounted Transformer-7.2/0.12 * 0.24 KV|Canada 2025
Matla: 50kVA
Matla: 7.2-0.12/0.24kV
Sebopeho: Tšireletso ea Dual Voltage & IFD
Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba tšepahalang ka ho fetisisa ba 50kva pole mounted transformer{7}}7.2/0.12*0.24 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

50kVA pole mounted transformer - Dual Voltage & IFD, e hahelletsoeng bakeng sa phepelo e tšepahalang ea Canada
01 Kakaretso
1.1 Tlhaloso ea Morero
Transformer ena ea 50 kVA single-phase pole{2}}e fana ka motlakase o bolokehileng le o tšepahalang bakeng sa malapa le likhoebo tse nyane. E pahiloe lipalong tsa lisebelisoa 'me e theolela tlase{4}}motlakase o matla ho tloha ho netweke ea ho ajoa (12,470 GRDY/7,200 V) ho ea ho 120/240 V e tloaelehileng ea tlhahiso bakeng sa lisebelisoa tsa 60 Hz tsa Amerika Leboea.
Transformer e na le motheo oa tšepe oa laminated o fetisang matla hantle pakeng tsa maqhubu a mantlha le a bobeli. Maqhubu a entsoe ka-aluminium ea boleng bo holimo 'me a sirelelitsoe ka botlalo ho sebetsana le khatello ea motlakase. Yuniti e fihlela katleho e phahameng (E kholo ho feta kapa e lekanang le 99.04%) ntle le{4}}tahlehelo ea mojaro oa 130 W le tahlehelo ea mojaro oa 492 W, 'me e na le 2.15% impedance (±10%) bakeng sa taolo e tsitsitseng ea motlakase tlas'a mojaro. Non-Load Tap Changer (NLTC) e nang le ±2×2.5% tap range e lumella ho feto-fetoha ha motlakase hantle. Sesebelisoa se kopaneng sa Internal Fault Detector (IFD) se beha leihlo transformer bakeng sa litaba tsa kahare. Sesebelisoa sa 9 kV high{16}}voltage arrester se sireletsa khahlanong le maqhubu. Transformer e sebelisa pholiso ea ONAN le ho kenya oli ea liminerale ho netefatsa hore e ts'epahala ha nako e telele-ka ntle.
Transformer ena e loketse libaka tsa bolulo, mapolasi le lits'ebeletso tse nyane tsa khoebo. E sebetsa hantle bakeng sa marang-rang a kabo ea mahaeng le a litoropong, li-extensions tsa marang-rang, le lisebelisoa tsa nakoana tsa matla. Tanka ea eona e tiisitsoeng le moralo o tiileng li etsa hore e tšepahale maemong a thata a kantle joalo ka lehloa, pula le mocheso o feteletseng.
1.2 Tlhaloso ea Setsebi
50kVA pole mounted transformer specifications and data sheet
|
E fetisetsoa ho
Canada
|
|
Selemo
2025
|
|
Mofuta
Pole mounted transformer
|
|
Standard
CSAC2.2-06/C802.1-23
|
|
Rated Power
50KVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
Motho a le mong
|
|
Mofuta oa ho Pholisa
ONA
|
|
Mokelikeli o thibelang metsi
Oli ea Liminerale
|
|
Voltage ea mantlha
12470GRDY/7200 V
|
|
Motlakase oa bobeli
120/ 240 V
|
|
Sehlopha sa Vector
Ii6
|
|
Polarity
Keketso
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
2.15%(±10%)
|
|
Katleho
E kholo ho feta kapa e lekana le 99.04%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
130 W
|
|
Ho Lahleheloa ke Moroalo
492 W
|
|
Lisebelisoa
Motšoantšisi oa 9kV HV
|
1.3 Litšoantšo
50kVA poleiti e pentiloeng ka transformer e pentiloeng le nameplate
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa

Ka li-pole- li-transformer tse kentsoeng, konokono e boetse e hahiloe hore e khone ho kopana le ho sisinyeha-e hanana le ho sisinyeha hore e lule e sireletsehile lipalong tsa lisebelisoa. E emelana le moea, leqhoa, le maemo a mang a kantle, ha e sa boloke{{3}tahlehelo ea thepa e le tlase - e leng senotlolo sa melapo e melelele e fepang malapa le likhoebo tse nyane.
2.2 Ho tsubella


Li-coil tsa rona li entsoe ke lihlopha tse nang le phihlelo tse latelang mekhoa e hlakileng. Basebeletsi ba ala foil ka thata bakeng sa likhoele tsa LV le koporo ea moea ka ho lekana bakeng sa likhoele tsa HV. Baokameli ba beha leihlo mehato le ho saena liteko tsa ho qetela. Motsoako ona oa mesebetsi ea matsoho, licheke, le tšebelisano-'moho li boloka li-transformer li tšepahala maemong a thata a masimong.
2.3 Tanka
Transformer e sebelisa tanka ea oli e koetsoeng{0}e koetsoeng ka botlalo, e tiileng{1}}, e hahiloeng ka litšepe tse thata. Ha ho li-pores, ha ho li-seams tse bohlasoa. Ka mor'a ho cheselletsa, tanka e ea tekong ea vacuum kapa ea ho tiea ha moea{4}}. Seseteme ea ho roala e ka ntle-grade: epoxy primer plus polyurethane finish, with all hardware corrosion{7}}a sireletsoa. Litheminale li latela lipeakanyo tse tloaelehileng, 'me sebaka se bolokiloe bakeng sa ba tšoarang le libaka tsa ho theola ntle le ho ama matla a ho phahamisa kapa li-angles tse ntseng li phahama. E loketse maemo a leholimo a mabe le tšebeletso e telele.

03 Ho paka le ho tsamaisa
3.1 Ho paka


4.2 Ho tsamaisa thepa


04 Ho kenya
Ho kenngwa ha Pole-Mounted Transformer
Tokiso ea Sebaka
Khetha sebaka se loketseng bakeng sa transformer. Mobu o lokela ho ba o tsitsitseng le o fumanehang, 'me setša se lokela ho ba haufi le lithapo tsa motlakase tse teng. Hlakola mafika, limela kapa litšitiso sebakeng seo.
Tlhahlobo ea Pole
Hlahloba palo ea lisebelisoa pele u kenya. Netefatsa hore e na le sebopeho se setle, ha e na mapetsong kapa ho bola, 'me e khona ho tšehetsa boima ba transformer ka polokeho.
Tlhahlobo ea Transformer
Hlahloba transformer bakeng sa matšoao leha e le afe a tšenyo. Sheba lihlahla, li-terminals, le likaroloana tsa ho pholisa ho netefatsa hore li hloekile ebile li maemong a nepahetseng.
Ho phahamisa Transformer
Sebelisa crane kapa hoist ho phahamisa transformer sebakeng. E sireletse ka thata ho palo ka liboutu le li-brackets tse ntseng li hola. Etsa bonnete ba hore e boemong bo botle ebile e tsitsitse.
Lihokelo tsa Motlakase
Hokela lithapo tse phahameng-le tse tlase{1}} tsa motlakase ho latela litaelo tsa moetsi. Etsa bonnete ba hore li-terminals tsohle li hloekile, li tiile, 'me li hlophisitsoe hantle.
Ho thethefatsa
Hokela sekontiri sa ho theola fatše ho rod e amohetsoeng ea fatše kapa tsamaiso ea fatše. Sena se fana ka polokeho khahlanong le liphoso tsa motlakase le ho ntlafatsa ts'epo ea sistimi.
Teko
Ka mor'a ho kenya, etsa liteko tse tloaelehileng tsa motlakase tse kang ho hanyetsa insulation, polarity, le ho hlahloba motlakase. Netefatsa hore transformer e sebetsa ka nepo pele o fana ka matla.
Tlhahlobo ea ho Qetela
Mookameli kapa moenjiniere o lokela ho etsa tlhahlobo ea ho qetela. Rarolla mathata leha e le afe kapa liphetoho tse hlokahalang ho finyella litekanyetso tsa polokeho le boleng.
Litokomane
Rekota liphetho tsohle tsa liteko, lintlha tsa lisebelisoa, le lintlha tsa ho kenya. Boloka litokomane tsena bakeng sa tlhokomelo le tšebeliso ea nako e tlang.

Hot Tags: 50kva pole mounted transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
167 kVA Power Pole Transformer-13.8 / 0.347 kV|Canad...
167 kVA Pole Distribution Transformer-14.4/0.6 kV|Ca...
75 kVA Utility Transformer-24.94 / 0.12 kV|Canada 2025
75 kVA Pole Mounted Transformer-7.97/0.12/0.24 kV|Ca...
167 KVA Pole Top Transformer-34.5/0.347 KV|Canada 2025
50 KVA Pole Mounted Transformer 3 Phase-2.4/0.6 KV|C...
Romela Inquiry