167 kVA Pole Mounted Distribution Transformer-24.94/0.12/0.24 kV|Canada 2024

167 kVA Pole Mounted Distribution Transformer-24.94/0.12/0.24 kV|Canada 2024

Naha: Canada 2025
Matla: 167 kVA
Matla: 24.94GrdY/14.4-0.12/0.24 kV
Sebopeho: ka IFD
Romela Inquiry

 

 

single pole mounted distribution transformer

Holimo Holimo, E Lula E Bulehile - Pole e tšoarellang-Li-Mounted Transformers bakeng sa Matla a sa Sitisoeng.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

167 kVA karolo e le 'ngoe ea pole mounted transformer e ile ea isoa Canada ka 2025. Matla a lekantsoeng a transformer ke 167 kVA e nang le pholiso ea ONAN. Motlakase oa mantlha ke 24.94GrdY/14.4 kV e nang le ± 2 * 2.5% tapping range (NLTC), motlakase oa bobeli ke 0.12 / 0.24 kV, 'me ba thehile sehlopha sa vector sa Ii6.

Pole ena ea 167kVA{1}}e behiloeng ka transformer ke tharollo e matla le e ts'epahalang e etselitsoeng ho ajoa ha motlakase ka mokhoa o hloahloa linetwekeng tsa motlakase tse holimo. E na le likarolo tsa bohlokoa tsa ts'ireletso le ts'ebetso, e netefatsa ts'ebetso e bolokehileng le e tsitsitseng maemong a fapaneng a tikoloho. Likarolo tse ka sehloohong li kenyelletsa sesebelisoa sa ho imolla khatello ea ho fokotsa liphoso tsa ka hare ka ho lokolla khatello e feteletseng, litšehetso tsa ho ts'oaroa ha li-surges tse ntseng li eketseha ho sireletsa khahlanong le overvoltages, le tsamaiso ea Internal Fault Detection (IFD) bakeng sa ts'ebetso e ntlafetseng le ho tsebahatsa phoso pele ho nako.

Ho feta moo, transformer e na le-circuit tap changer e timang, e lumellang ho feto-fetoha ha sekhahla sa motlakase hore se lumellane le litlhoko tse sa tšoaneng tsa phalliso ha-e matlafatsoa. E kopane, e tšoarella, 'me e entsoe bakeng sa tlhokomelo e bonolo, yuniti ena e loketse lisebelisoa le lits'ebetso tsa indasteri tse hlokang kabo ea motlakase e tšepahalang.

 

 

 

1.2 Tlhaloso ea Setsebi

167 kVA pole mounted transformer specifications type le data sheet

E fetisetsoa ho
Canada
Selemo
2025
Mofuta
Pole mounted transformer
Standard
CSA C2.2-06
Rated Power
167 kVA
Khafetsa
60HZ
Mokhahlelo
1
Polarity
Kekeletso
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
24.94GrdY/14.4 kV
Motlakase oa bobeli
V0.12/0.24 kV
Lintho Tse Hlahang
Aluminium
Angular displacement
Ii6
Tšitiso
3%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
0.295 kW
Ho Lahleheloa ke Moroalo
2.255 kW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

 

1.3 Litšoantšo

167 kVA poling mounted transformer diagram to the size and size.

pole mounted distribution transformer diagram pole mounted distribution transformer nameplate

 

 

02 Tlhahiso

2.1 Konokono

Lithapa tsa tšepe tsa silicon li lula li holisoa ka mokhoa o nepahetseng hore e be karolo ea selikalikoe kapa e pota-potileng-karolo (mohlala, khutlonnetsepa kapa e haufi-ea chitja) ho etsa potoloho e koetsoeng ea makenete. Ka mor'a matsoelintsoeke, annealing e etsoa ho imolla khatello ea kelello le ho ntlafatsa thepa ea makenete. Tsela e sa tsitsang ea makenete e felisa tahlehelo e eketsehileng e bakoang ke ho se lumellane ha matla a khoheli ho manonyeletso a li-cores tsa laminated. Potoloho ea makenete e koetsoeng e fokotsa ho lutla ha flux, e netefatsa phepelo e ts'oanang ea matla a khoheli, ka katleho ea mantlha e fetang 99%.

single pole mounted transformer iron core

 

2.2 Ho tsubella

single pole mounted transformer wire winding

Sebopeho sa LV foil + HV wire winding configuration ho palo{1}}transformer e palamisitsoeng e fumana tekanyo e nepahetseng ea ts'ebetso e phahameng, e ts'epahalang, le litšenyehelo tse tlase tsa tlhokomelo. Sebopeho se bataletseng se eketsa sebaka se pholileng, se matlafatsang katleho ka oli kapa moea o pholileng. Multi-layer insulation optimize kabo ea motlakase hantle, ho fokotsa partial discharge (PD). Maqhubu a foil a fokotsa deformation ea radial; HV wire windings e sebelisa sekontiri se matlafalitsoeng bakeng sa ho phalla ho feteletseng. Aluminium foil e fokotsa boima ba 'mele, e loketseng bakeng sa ho phahamisa lipalo.

 

2.3 Tanka

Lihlahisoa tsa rona li kopana le sehlopha sa C4 corrosion resistance.

1- Ntlafatso ea Taolo ea Ts'ebetso Re matlafalitse ts'ebetso ea rona ea ho roala ka mokhoa o ntlafalitsoeng oa ho lokisa bokaholimo, ho hloekisa ka thata, le liprothokholo tsa kalafo ea lik'hemik'hale ho felisa tšilafalo ea substrate, ha re ntse re netefatsa lintlha tse netefalitsoeng tsa botenya.

2- 2-Kaonafatso ea Sebopeho Re kentse tšebetsong kalafo e tiisitsoeng ea seam ea weld manonyeletsong 'ohle a bohlokoa ho thibela ho kenella ha mongobo ka har'a li-transformer tsa kahare ka nepo.

C4 corrosion resistance oil tank

2.4 Qetello e Tšoarellang

 

167 kVA single phase pole mounted transformer

Li-transformer li ne li pentiloe ka thata ho ea ka litlhaloso. Likarolo tsa tšepe li ile tsa hloekisoa esale pele 'me tsa hloekisoa ka botlalo ho tsoa li-burrs, mafome le litšila. Lipente tse nang le tokelo ea molao kapa lipente tsa phofo-polyester kapa polyurethane{3}li ne li sebelisoa ka mokhoa o ts'oanang, li koahela likarolo tsohle le ho kopanya tanka le kampeng bakeng sa tšireletso e felletseng. ASA 70 grey finish e kopana le ANSI C57.12.28 mme e feta tekolo ya ho fafatsa letswai ya dihora tse 1500{8}, e nang le bokahodimo bo senang lerole mme bo sa angwa ka mora ho penta.

 

2.5 Kopano ea ho Qetela

1. Kopano e Matsoho

Kenya li- windings tsa HV le LV ka tatellano mokokotlong oa leqeba, ho netefatsa boemo bo nepahetseng ba likarolo tsa ho pata le ho tiisa ka mochini.

2. Lihokelo tsa Motlakase

Hokela li-lead (li-terminals tsa HV/LV, tap changer) ka tjheseletsa kapa bolting ho tlatsa li-circuits tsa motlakase lipakeng tsa matsoelintsoeke, ebe u sheba hore na ho hanana le mang.

3. Ho Omisa Likhoele{1}

Mokhoa oa ho Omisa Oven: Beha karolo e sebetsang e kopaneng (core + windings) ka ontong e omisang hore ho be le vacuum e chesang-moea o potoloha kapa mouoane{2}}o omisa ka likhato tse 105-130 ka lihora tse 48-72 ho fihlela mongobo o kenang o ka Tlase kapa o lekana le 0.5%.

4. Ho kenya Tanka

Ka potlako fetisetsa karolo e omisitsoeng e sebetsang ka har'a tanka ho thibela ho kenngoa ha mongobo, ebe u sireletsa ka li-clamping bolts.

5. Ho kenya lisebelisoa

Kenya li-bushings, valve ea liphallelo, IFD, joalo-joalo.

6. Ho Tlatsa Oli ea Vacuum

Kenya oli e omileng e sireletsang tlas'a vacuum.

pole mounted distribution transformer assembly

 

03 Pole Mounted Distribution Transformer Parts

HV Bushing LV Bushing
HV Bushing LV Bushing
Copper Strip Arrester Support
Leqhoa la Koporo Tšehetso ea ho Tšoara
IFD Pressure Rellef Device
IFD Sesebelisoa sa Rellef Press
Off-circuit Tap Changer Grounding Terminal
E tima{0}circuit Tap Changer Terminal ea ho Grounding

 

04 Ho etsa liteko

pole mounted distribution transformer fat
pole mounted transformer factory testing

 

 

05 Ho paka le ho Romela

pole mounted distribution transformer packing
pole mounted distribution transformer shipping

06 sebaka le kakaretso

Joalo ka karolo ea bohlokoa ho marang-rang a phano ea motlakase, -mohato o mong oa lipalo{1}}se feto-fetohang o fana ka moralo o kopaneng, oa ho kengoa ha bonolo, le ts'ebetso e tšepahalang, e leng se etsang hore e be se loketseng bakeng sa marang-rang a litoropong le a mahaeng, lirapeng tsa boikhathollo tsa indasteri le phepelo ea motlakase libakeng tsa bolulo. Ka boitlamo ba boleng le boqapi, re ikitlaelletsa ho fana ka litharollo tsa motlakase tse bolokehileng, tse sebetsang hantle le tse tšoarellang ho bareki lefatšeng ka bophara. Ka kopo ikopanye le rona bakeng sa tlhaiso-leseling e batsi kapa likhetho tsa litšebeletso tse ikhethileng.

167kva pole mounted distribution transformer

 