500 KVA Ke Eng Pad Mounted Transformer-12.47/0.6 KV|Canada 2024
Matla: 500kVA
Matla: 12.47Grdy/7.2 X 4.16Grdy/2.4-0.6y/0.347 kV
Tšobotsi: Ka IFD

Motlakase o ka tšeptjoang, o sebetsang hantle, le o bolokehileng ka 500 kVA pad-motlakase o kentsoeng, o fana ka motlakase o tsitsitseng-mohato oa boraro bakeng sa tšebeliso ea khoebo, bolulo le indasteri.
01 Kakaretso
1.1 Tlhaloso ea Morero
Ka 2024, SCOTECH e ile ea fana ka 500 kVA -phase three-mohau oa transfoma e phahamiselitsoeng ho ea Canada. E entsoe ho latela CSA C227.4:21 mme e hahiloe bakeng sa tšebeliso e tšepahalang ea matla meahong ea khoebo, matlong le lifemeng tse nyane.
Pad-transformer e palamisitsoeng ke mofuta oa transformer e kentsoeng boemong ba fatše holim'a motheo oa konkreite. E koaletsoe ka ho feletseng 'me hangata e na le{2}moetso o ka pele o shoeleng. Sena se boloka likarolo tsa motlakase{4} tse phahameng ka har'a khabinete e notletsoeng. E sireletsa sechaba le basebetsi ba litšebeletso. E boetse e lumella ho fihlella habonolo bakeng sa tlhokomelo. Thepa e na le pete e tiisitsoeng{8}}mme e behiloe holim'a letlapa la konkreite bakeng sa tšebeliso e sireletsehileng ea kantle. E fetola matla a mahareng (12.47 / 4.16 kV) ho ea ho matla a tlase (0.6 kV) mme e fana ka matla a tsitsitseng le a sebetsang ho basebelisi.
E na le sistimi e pholileng ea ONAN e nang le insulation ea oli ea liminerale, e fanang ka phepelo e ntle ea mocheso le bophelo bo bolelele ba ts'ebeletso. Transformer e matha ka 12.47 / 4.16 kV ka lehlakoreng le ka sehloohong le 0.6 kV ka lehlakoreng la bobeli. E sebelisa sehlopha sa li-vector tsa YNyn0 ho boloka-matla a mararo a leka-lekana. E na le aluminium windings, 5% impedance, le 99.5% e sebetsang hantle. E sebetsa ka tahlehelo e tlase mme e boloka motlakase o tsitsitse tlas'a mojaro o felletseng.
1.2 Tlhaloso ea Setsebi
500kVA pad ea mekhahlelo e meraro e kentsoeng li-transformer le leqephe la data
|
E fetisetsoa ho
Canada
|
|
Selemo
2024
|
|
Mofuta
Transformer ea mekhahlelo e meraro
|
|
Standard
CSA C227.4:21
|
|
Rated Power
500KVA
|
|
Khafetsa
60HZ
|
|
Fepa
Loop
|
|
Pele
E shoeleng
|
|
Mokhahlelo
boraro
|
|
Mofuta oa ho Pholisa
ONA
|
|
Mokelikeli o thibelang metsi
Oli ea Liminerale
|
|
Voltage ea mantlha
12.47(4.16) kV
|
|
Motlakase oa bobeli
0.6 kV
|
|
Sehlopha sa Vector
YNyn0
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
5%
|
|
Katleho
99.5%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
Ka tlase ho kapa ho lekana le 1090 W
|
|
Ho Lahleheloa ke Moroalo
Ka tlase ho kapa ho lekana le 5800 W
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
500kVA pad ea mekhahlelo e meraro e kentsoeng setšoantšo sa transformer le nameplate
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa
Maoto a mahlano-e fana ka ts'ehetso e matla le botsitso. E thusa ho fokotsa ho lutla ha metsi le{2}}khatello e khutšoane ea potoloho. Sebopeho sena se etsa hore transformer e bolokehe, e tsitsitse, 'me e tšoarelle, esita le ha e sebetsa ka mojaro o boima kapa maemo a ka ntle.
2.2 Ho tsubella
Haholo-holo bakeng sa litlhophiso tsa YNyn0, basebetsi ba ela hloko haholo-holo ntlha e sa nke lehlakore le ho leka-lekana ha mokhahlelo nakong ea matsoelintsoeke ho etsa bonnete ba hore-mohato o meraro oa potoloho ea matla a khoheli le{2}}mohau o khuts'oane. Moralo oa compact winding o fokotsa tahlehelo ha o ntse o boloka mocheso o nepahetseng.
2.3 Tanka

Tanka ea transformer e tiisitsoe ka sekoahelo se bolted mme se entsoe ka tšepe e bonolo. E ka nka khatello ea ka hare ea 50 kPa ntle le ho lutla kapa ho senyeha ho sa feleng ho feta 0.25% ea diagonal e holimo. Khabinete e etselitsoe hore e se ke ea kena-kenana le-e hanana le boemo ba leholimo-. Liboutu tsa pentahead tse hapuoeng li sebelisoa tumellanong le litlhoko tsa CSA C227.4.
2.4 Kopano ea ho Qetela
Re khomarela mekhoa e tloaelehileng ea ts'ebetso, re fana ka tataiso e hlakileng bakeng sa mohato o mong le o mong oa kopano ea transformer le ho fokotsa ho se tsitse ha ts'ebetso ea matsoho. Ha re kopane le sistimi ea ntlafatso ea sehlopha sa profeshenale, ka koetliso e hlophisitsoeng le{1}}mokhoa oa boithuto, re netefatsa hore mosebelisi e mong le e mong o khona ho etsa{2}}mosebetsi o tloaelehileng. Motsoako ona o phethahetseng oa ts'ebetso le batho ba theha motheo oa boleng ba sehlahisoa sa rona se tsitsitseng ka ho fetisisa.
03 Teko
Teko ea Teko le Teko e Tloaelehileng
|
CSA C227.4-21 |
Mekhahlelo e meraro-, -li-transformer tse phahamisitsoeng tse nang le li-insulated high{2}}lihokelo tsa motlakase |
|
CSA-C802.1-13 (R2022) |
Maemo a Tlatsi a Sebetsang bakeng sa Mokelikeli{{0}O Tlatsitse Li-Transformer tsa Phano |
1. Litekanyo tsa ho hanyetsa
2. Karo-karolelano Liteko
3. Teko ea Kamano ea Phase
4. Ha ho Tahlehelo ea Mojaro 'me Ha ho na Mojaro Hona Joale
5. Litahlehelo tsa Load Impedans Voltage le Katleho
6. Teko ea Voltage e sebelisitsoeng
7. Induced Voltage E mamella Teko
8. Teko ea ho Lutla ka Khatello ea Li-transformers tse qoelitsoeng ka Metsi
9. Tekanyo ea ho hanyetsa Insulation
10. Teko ea Dielectric ea Oli
Liphetho tsa liteko


|
|
Ntho ea Teko |
Yuniti |
Kamohelo Litekanyetso |
Litekanyetso Tse Lekanyelitsoeng |
Qetello |
|
1 |
Litekanyo tsa ho hanyetsa |
% |
Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane |
1.27 |
Feta |
|
2 |
Liteko tsa Karolelano |
% |
Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5% |
-0.04-0.10 |
Feta |
|
3 |
diteko- tsa dikamano |
/ |
YNyn0 |
YNyn0 |
Feta |
|
4 |
Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale |
/ |
I0 :: fana ka boleng bo lekantsoeng |
0.37% |
Feta |
|
P0: fana ka boleng bo lekantsoeng |
0.7317kW |
||||
|
mamello ea ho se lahleheloe ke moroalo ke +10% |
/ |
||||
|
5 |
Litahlehelo tsa tahlehelo ea matla a motlakase le katleho |
/ |
T:85 likhato mamello bakeng sa impedance ke ± 7.5% mamello ea tahlehelo ea boima kaofela ke +6% |
/ |
Feta |
|
Z%: boleng bo lekantsoeng |
5.35% |
||||
|
Pk: boleng bo lekantsoeng |
4.483kW |
||||
|
Pt: boleng bo lekantsoeng |
5.247kW |
||||
|
Katleho e seng ka tlase ho 99.05% |
99.29% |
||||
|
6 |
Teko ea Voltage e sebelisitsoeng |
kV |
HV:34kV 60s LV: 10kV 60s |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
7 |
Teko ea ho mamella Voltage e kentsoeng |
kV |
Matla a sebelisoang (KV): 2 Ur |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
Nako:30 |
|||||
|
Hangata (HZ): 240 |
|||||
|
8 |
Leakage Test |
kPa |
Khatello e sebelisitsoeng: 20kPA Nako: 12h |
Ha ho na leakage le che Tšenyo |
Feta |
|
9 |
Tekanyo ea ho hanyetsa Insulation |
GΩ |
LV-HV ho ea fatše |
7.8 |
/ |
|
HV&LV ho ea fatše |
8.0 |
||||
|
10 |
Tlhahlobo ea oli |
/ |
Matla a Dielectric; |
51.8 kv |
Feta |
|
Mongobo |
11.5 mg / kg |
||||
|
Ntho ea ho senya |
0.00298% |
||||
|
Furan Analysis |
Ka tlase ho kapa ho lekana le 0.1 |
||||
|
Tlhahlobo ea Khase ea Chromatography |
/ |
04 Ho paka le ho Romela



05 Sebaka le Kakaretso

Sesebelisoa sa rona sa 500 kVA{1}}phase three phase-motlakase se fana ka matla a ts'epahalang le a sebetsang bakeng sa marangrang a phano a Canada. E kopana le litekanyetso tsa CSA C227.4:21. Transformer e na le-mohaho o matla oa maoto le matsoho a mahlano le mapheo a nepahetseng a aluminium. Tanka e tiisitsoe ebile e thibela boemo ba leholimo. Basebetsi ba nang le litsebo ba kopanya sehlopha ka seng ka hloko. Transformer e boloka{11}}mohato oa boraro o le boemong bo botle 'me e sebetsa ka tahlehelo e tlase. E sebelisa pholiso ea ONAN 'me e fana ka motlakase o tsitsitseng tlas'a mojaro o feletseng.
Hot Tags: Sefetoleli se kentsoeng ka pad ke eng, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
300 kVA Oli e Tlatsang Transformer-13.2 / 0.48 kV|Gu...
1000 kVA Residential Pad Mounted Transformer-22.86/0...
75 kVA Pad Mount-23/0.208 kV|USA 2025
2000 kVA Pad Mount Transformer-25/0.6 kV|Canada 2025
300 KVA Pad Mounted Transformer Residential-12.47 * ...
500 KVA Radial Feed Transformer-12.47 * 4.16/0.6 KV|...
Romela Inquiry