1000 kVA Residential Pad Mounted Transformer-22.86/0.48 Kv|Sebelisa 2024

1000 kVA Residential Pad Mounted Transformer-22.86/0.48 Kv|Sebelisa 2024

Naha: Amerika 2024
Matla: 1000KVA
Matla: 22.86/0.48kV
Feature: e nang le surge arrester
Romela Inquiry

 

 

mount transformer

Theknoloji e nchafalitsoeng, matla a boleng -- a mekhahlelo e meraro ea pad-mounted transformer, e tsamaisang tsoelo-pele e tsitsitseng!

 

01 Kakaretso

1.1 Semelo sa Morero

1000 kVA pad mounted transformer e ile ea isoa Amerika ka 2024. Matla a lekantsoeng a transformer ke 1000 kVA e nang le pholiso ea ONAN. Motlakase oa mantlha ke 22.86GrdY/13.2kV ​​e nang le ± 2 * 2.5% tapping range (NLTC), motlakase oa bobeli ke 0.48 / 0.277kV, ba thehile sehlopha sa vector sa YNyn0, 'me ke sesebelisoa sa loop le transformer e ka pele e shoeleng.

Litheminale tse phahameng{{0} tsa motlakase oa transfoma ena ea mekhahlelo e meraro li na le feed-thru insert, tse etselitsoeng ho hokela li-plug tsa elbow cable kapa li-insulated elbow surge arrester. Moqapi ona o tiisa ka ho feletseng likarolo tse phelang ka har'a thepa e sireletsang, ho etsa mohaho o feletseng oa insulated. Bokaholimo bo lula bo sa sebetse-ka mokhoa o ka tlase), ho netefatsa polokeho ea basebetsi. Maemong a tshohanyetso, polaka ya thapo e ka tjhesa-ya swantshwa ka tlasa transfoma e felletseng, mme e sebetsa e le switch switch ha ho hlokahala.

Ho feta moo, li-line indicators tse phelang-kapa fault indicators li ka kengoa li-cable plugs ho ipapisitsoe le litlhoko tsa ts'ebetso ho beha leihlo boemo ba sistimi kapa ho fumana liphoso. Ka holim'a{{2}lebota la kamore e ka pele ea motlakase oa transfoma, haufi le-voltage bushing e phahameng, lebota-e kentsoeng ka litšepe le ts'irelelitsoe ho sireletsa litulo tsa boikhethelo{5}ho tima lihokelo tse insulated bushing. Ha plug ea cable e ntšoa e ntse e matlafalitsoe, e ka kenngoa hang-hang ho stand{7}}off bushing connector ho netefatsa polokeho ea ts'ebetso le botsitso ba sistimi.

 

 

1.2 Tlhaloso ea Setsebi

1000 KVA e hlalosang mofuta le leqephe la data

E fetisetsoa ho
Amerika
Selemo
2024
Mofuta
Transformer e kentsoeng ka pampiri
Standard
IEEE Std C57.12.34-2022
Rated Power
1000KVA
Khafetsa
60 HZ
Mokhahlelo
3
Fepa
Loop
Pele
E shoeleng
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
22.86GRDY/13.2 KV
Motlakase oa bobeli
0.48/0,277 KV
Lintho Tse Hlahang
Aluminium
Angular displacement
YNyn0
Tšitiso
5.75%(±7.5%)
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
1.095KW
Ho Lahleheloa ke Moroalo
7.855KW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

1000 KVA pad mounted transformer diagram le boholo.

three phase transformer diagram three phase transformer nameplate

 

 

02 pad mounted transformer Accessories

2.1 Bay-O-Net Fuse

Transformer e sebelisa Bay-O{1}}Fuse ea ho leleka Net lehlakoreng la mantlha, e fana ka tšireletso ea mantlha e tsamaellanang hantle le maemo a ts'ebetso ea letsatsi le letsatsi. E hlakola liphoso tse tloaelehileng ka har'a bokhoni ba eona mme e lumella sebaka se bonolo sa sebaka ha ho hlokahala. E sebetsa 'moho le sebaka sa ka hare sa hona joale-se fokotsa sekhahla, se theha ts'ireletso e hokahaneng e bolokang ts'ebetso e ts'epahalang tlas'a maemo a tloaelehileng le a phahameng a phahameng.

Bay-O-Net Fuse

 

2.2 Fuse ea moeli ea hajoale

Current Limit Fuse

 

Ho kentsoe lifuse tse lekantsoeng tsa ka hare-ho sebetsa{1}}litšitiso tsa mantlha tsa matla tse fetang sebaka se sitisang Kou-O{3}}Net fuse. E arabela ka potlako, e fokotsa phoso ea hona joale le ho fokotsa khatello ea mocheso holim'a maqhubu. Ka ho sebetsa ka letoto le nang le fuse ea ho lelekoa, fuse ea CL e fana ka karolo ea bobeli e sireletsang, e netefatsang hore transformer e khona ho mamella maemo a thata haholo ha e ntse e boloka polokeho ea sistimi le ho tšoarella-nako e telele.

 

2.3 25 kV Elbow Arrester

Transformer e na le 25 kV elbow{1}}mofuta oa ho ts'oara surge o hoketsoeng ka har'a sehokelo sa loadbreak. E fana ka tšireletso e tsoelang pele khahlanong le ho phahama ha lehalima le ho fetola li-transients tse ka hlahang moleng oa mantlha. Sekoahelo se thusa ho boloka mochini o kenang ka har'a meeli e sireletsehileng, se ts'ehetsa ts'ebetso e tsitsitseng maemong a tloaelehileng a phano, le ho boloka ts'epo e lebelletsoeng ho tsoa-lisebelisoa tse ka pele- tse kentsoeng.

25 KV Elbow Arrester
 

 

03 Ho etsa liteko

Che.

Ntho ea Teko

1

Litekanyo tsa ho hanyetsa

2

Liteko tsa Karolelano

3

diteko- tsa dikamano

4 Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale
5 Litahlehelo tsa tahlehelo ea matla a motlakase le katleho
6 Teko ea Voltage e sebelisitsoeng
7 Teko ea ho mamella Voltage e kentsoeng
8 Leakage Test
9 Tekanyo ea ho hanyetsa Insulation
10 Tlhahlobo ea oli

 

Applied Voltage Test of transformer
Induced Voltage Withstand Test of transformer

 

 

04 Ho paka le ho Romela

 

packing of mount transformer
mount transformer transportation

 

05 Sebaka le Kakaretso

Qetellong, li-transformer tsa rona tse tharo-tse tharo- tse kentsoeng li eme ka pele ho litharollo tse tšepahalang le tse sebetsang hantle tsa kabo ea motlakase. E entsoe ka theknoloji e tsoetseng pele le boqapi bo phahameng, li-transformer tsena li fana ka ts'ebetso e ke keng ea lekanngoa le polokeho bakeng sa lits'ebetso tse fapaneng. Ebang ke bakeng sa litlhoko tsa khoebo, tsa indasteri, kapa tsa ts'ebeliso, li-transformer tsa rona li netefatsa phano ea motlakase e tsitsitseng, e ntlafatsa ts'ebetso e nepahetseng, le ho khothaletsa botsitso. Tšepa boitlamo ba rona ba boleng le boqapi ho matlafatsa bokamoso ba hau ka nepo. Ikopanye le rona kajeno ho ithuta haholoanyane ka hore na li-transformer- tse tharo tsa mekhahlelo{7}} tse kentsoeng li ka khotsofatsa litlhoko tsa hau tsa tharollo ea matla!

power distribution solutions

 

Hot Tags: pad mounted transformer, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry