300 KVA Pad Mounted Transformer Residential-12.47 * 4.16/0.208 KV|Canada 2024

300 KVA Pad Mounted Transformer Residential-12.47 * 4.16/0.208 KV|Canada 2024

Naha ea thomello: Canada 2024
Matla: 300kVA
Matla: 12.47Grdy/7.2-0.208y/0.12 kV
Tšobotsi: Ka IFD
Romela Inquiry

 

300 kVA pad mounted transformer residential

Transformer e sebetsang hantle le e tšoarellang ea 300 kVA pad{1}} bakeng sa kabo e tšepahalang ea motlakase kantle.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

Ka 2024, moreki oa Canada o ile a fumana a300 kVA -phase three phase-transformer e kentsoeng, e entsoeng le ho etsoa ka tumellano e feletseng le CSA Standard C227.4:21. Karolo ena e reretsoe ho qhomisoa ka ntle-ka holim'a metheo ea konkreite 'me e loketse ho sebelisoa litsing tse thehiloeng hantle.

Transformer ena e na le moetso o sa sebetseng-ka pele bakeng sa polokeho le ho ts'epahala lits'ebetsong tsa kantle. E sebelisa pholiso ea ONAN le oli ea diminerale bakeng sa ho kenya letsoho. Maqhubu a aluminium a fana ka tekanyo e ntle ea ts'ebetso, boima le litšenyehelo. Transformer e lekantsoe 300 kVA, 60 Hz. Matla a mantlha ke 12.47 kV. Matla a bobeli ke 0.208 kV. Sehlopha sa vector ke YNyn0.

Matla a 300 kVApad mounted transformerSebaka sa bolulo ha se na{0}}load tap changer (NLTC). Thepa e fetolang ke ea mofuta oa cap le wrench, e fana ka sebaka sa ± 2 × 2.5% sa ho theipi, ho latela CSA C227.4 Clause 5.1.9, ho netefatsa ts'ebetso e bonolo le ts'ebetso e tšepahalang.

Yuniti e boetse e kenyelletsa kaho ea mantlha ea maoto a 5 bakeng sa botsitso le ho fokotsa tahlehelo ea makenete litsing tse hokahantsoeng tsa GrdY-GrdY. Grounding e fanoa ka bracket e theohileng ea koporo e kentsoeng lebaleng la fatše, e tsamaellanang le CSA C227.4, le ho lumella ho hokeloa ho sireletsehileng ha li-clamp tsa fatše tse sebetsang.

E etselitsoe ho sebetsa hantle haholo, transformer ena e fihlela katleho ea 98.94%, e se{1}}tahlehelo ea mojaro Ka tlase kapa ho lekana le 705 W le tahlehelo ea thepa Ka tlase ho kapa ho lekana le 4000 W. E hahiloe hore e sebetsane le maemo a kantle, e tla le lisebelisoa tse lumellanang le CSA{5}'me e emela marang-rang a ka tšeptjoang, a tšoarellang bakeng sa Cana.

 

 

 

1.2 Tlhaloso ea Setsebi

Tlhaloso ea bolulo ea 300 kVA pad e kentsoeng transformer le leqephe la data

E fetisetsoa ho
Canada
Selemo
2024
Mofuta
Transformer ea mekhahlelo e meraro
Standard
CSA C227.4:21
Rated Power
300KVA
Khafetsa
60HZ
Fepa
Radial
Pele
E shoeleng
Mokhahlelo
tharo
Mofuta oa ho Pholisa
ONA
Mokelikeli o thibelang metsi
Oli ea Liminerale
Voltage ea mantlha
12.47 kV
Motlakase oa bobeli
0.208 kV
Sehlopha sa Vector
YNyn0
Lintho Tse Hlahang
Aluminium
Tšitiso
4 %
Katleho
98.94 %
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
Ka tlase ho kapa ho lekana le 705 W
Ho Lahleheloa ke Moroalo
Ka tlase ho kapa ho lekana le 4000 W
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

300 kVA pad mounted transformer foto le nameplate

300 kVA pad mounted transformer residential drawing 300 kVA pad mounted transformer residential nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Maoto a mahlano-a fana ka tekanyo e ntle ea makenete ka boholo bo bonyenyane. E nepahetse bakeng sa pad-li-transformer tse kentsoeng. Sebopeho sa compact se boloka sebaka le litšenyehelo. Tsela e sebetsang ea makenete e theola tahlehelo ea matla 'me e thusa transformer ho sebetsa hantle libakeng tse thata. Karolo e 'ngoe le e' ngoe ea tšepe e kenngoa ka hloko. Lipampiri li botenya ba 0.30-0.35 mm mme li na le silicon ea 2-4.8%. Sesebelisoa sena se thusa ho fokotsa tahlehelo ea li-eddy current le hysteresis.

 

2.2 Ho tsubella

Likhoele tsohle li entsoe ka hloko ka foil ea aluminium le terata. Ba jala mocheso hantle mme ba boloka tahlehelo e le tlase. Ka taolo le ts'ebetso e ntle haholo, li-transformer tsena li sebetsa ka ts'epahalo 'me li se li loketse ho kengoa -pad. E na le YNyn0-mohato oa mekhahlelo e meraro, mohato o mong le o mong ke letsoho-ke maqeba a litsebi tse hloahloa ho netefatsa khokahanyo e nepahetseng le phallo e leka-lekaneng ea makenete.

300 kVA pad mounted transformer residential winding

 

2.3 Tanka

300 kVA pad mounted transformer residential mild-steel-oil tank

Libaka tsa bolulo tsa 300 kVA pad mounted transformer e tla ba litanka tse tiisitsoeng tse bobebe{{1} tsa tšepe tse nang le likoahelo tse koetsoeng ka liboutu. Moralo o tla netefatsa bots'epehi ba mochini tlas'a teko ea khatello ea 50 kPa, ntle le ho lutla kapa ho khopama ho sa feleng ho fetang 0.25% ea diagonal e kaholimo. Litanka li tla lumellana le boemo ba leholimo- 'me li sebetsane le maemo a leholimo-tse hanyetsanang, tse nang le liboutu tsa pentahead ho latela litlhokahalo tsa CSA C227.4.

 

2.4 Kopano ea ho Qetela

Nakong ea ts'ebetso ea ho kopanya li-transformer, ha re sebetse feela ka phaposing e hloekileng e nang le mocheso le mongobo o sa feleng, empa hape re thehile sistimi e felletseng ea ts'ebetso. Ho tloha kopanong ea transformer ho isa khokahanyo e etellang pele, mohato o mong le o mong o tataisoa ke lits'ebetso tse hlakileng, tse lekantsoeng, ho netefatsa ts'ebetso e nepahetseng le e nepahetseng ka har'a tikoloho e otlolohileng. Tsepamiso ena e habeli tikolohong le lits'ebetsong e netefatsa hore lihlahisoa tsa rona li lula li boloka boemo bo holimo ba boleng ba boqapi.

 

2.5 300 Lintlha tsa KVA Pad Mounted Transformer

 

300 kVA pad mounted transformer residential Bayonet Fuse ELSP Fuse
Bayonet Fuse le ELSP Fuse
300 kVA pad mounted transformer residential Tap Changer WSLII3 6320-6X5
Tlanya Changer WSLII3 6320-6X5
300 kVA pad mounted transformer residential HV Bushing Well 15 kV 200 A
HV Bushing Well 15 kV 200 A
300 kVA pad mounted transformer residential Pressure Relief Valve Vacuum Pressure Gauge YZ-70
Sekhahla sa Phallo ea Khatello & Vacuum Pressure Gauge YZ-70
300 kVA pad mounted transformer residential Thermometer of the maximum indicating type
Thermometer ea boholo ba mofuta o bontšang
300 kVA pad mounted transformer residential Oil Level Indicator UHZ-01
Letšoao la Boemo ba Oli UHZ-01
300 kVA pad mounted transformer residential LV Bushing 1250 A 6-Hole
LV Bushing 1250 A 6-Hole
 300 kVA pad mounted transformer residential Drain Valve
1" Drain Valve e nang le Sampler ea 3/8".
300 kVA pad mounted transformer residential IFD & Upper Fill Valve
IFD & 1" Valve e Tlatsang ka Holimo

03 Ho etsa liteko

Teko ea Teko le Teko e Tloaelehileng

CSA C227.4-21

Li-transformer tse - tse tharo, - tse phahamisitsoeng tse nang le insulated

{0}lihokelo tsa motlakase tse phahameng

CSA-C802.1-13 (R2022)

Maemo a Tlatsi a Sebetsang bakeng sa Mokelikeli{{0}O Tlatsitse Li-Transformer tsa Phano

 

300 kVA pad mounted transformer residential testing
300 kVA pad mounted transformer residential FAT

1. Litekanyo tsa ho hanyetsa
2. Karo-karolelano Liteko
3. Teko ea Kamano ea Phase
4. Ha ho Tahlehelo ea Mojaro 'me Ha ho na Mojaro Hona Joale
5. Litahlehelo tsa Load Impedans Voltage le Katleho
6. Teko ea Voltage e sebelisitsoeng
7. Induced Voltage E mamella Teko
8. Teko ea ho Lutla ka Khatello ea Li-transformers tse qoelitsoeng ka Metsi
9. Tekanyo ea ho hanyetsa Insulation
10. Teko ea Dielectric ea Oli
 

Liphetho tsa liteko

1. Tekanyo ea Khanyetso

Ho hanyetsa ha DC ho ile ha lekanyetsoa ho netefatsa botšepehi bo sa feleng le tekanyo ea mohato.
Sekhahla se phahameng sa ho se lekane:3.51%, ka har'a meeli e amohelehang.

6. Teko ea Voltage e sebelisitsoeng

10 kV e sebelisoa ho phethola moea oa LV ka metsotsoana e 60.
Ha ho na ho senyeha kapa ho sa tloaelehang ho hlokometsoeng.

2. Teko ea Karo-karolelano

Karo-karolelano ea motlakase e ile ea lekoa tabeng ea ho tlanya ka sehloohong ho netefatsa ho nepahala.
Ho kheloha ho lekantsoeng:-0.01% ho ea ho -0.03%, hantle ka hare ho ± 0.5% mamello.

7. Induced Voltage E mamella Teko

2Ur e sebelisoa ho 240 Hz bakeng sa metsotsoana e 30.
Ha ho na ho hloleha ha insulation ho etsahetse.

3. Teko ea Kamano ea Phase

Sehlopha sa vector se netefalitsoe e leYNyn0, e lumellanang le litlhaloso tsa nameplate.

8. Leakage Test

Khatello ea 20 kPa e bolokiloe lihora tse 12.
Ha ho dutla kapa tshenyo ya motjhini e fumanweng.

4. Che-Tahlehelo ea Meroalo le Monate oa Hona Joale

E lekantsoe ka voltage e lekantsoeng ho fumana ts'ebetso ea mantlha.

Nako e thabisang (I₀):0.26%

Ha ho{0}tahlehelo (P₀):0.4693 kW
Ka tumello ea +10% ea mamello.

9. Insulation Resistance

LV-HV ho ea fatše:17.9 GΩ

HV & LV ho qala:10.3 GΩ
Boemo ba insulation boa khotsofatsa.

5. Tahlehelo ea Mojaro, Tšitiso & Tšebeliso e Ntle

Teko e entsoe ka mocheso o lekanang oa likhato tse 85.

Matla a impedans (Z%):4.25%

Tahlehelo ea mojaro (Pk):3.419 kW

Kakaretso ea tahlehelo (Pt):3.909 kW

Katleho:99.17%(E kholo ho feta kapa e lekana le 98.94% e hlokahalang)

Litekanyetso tsohle li kopana le mamello e boletsoeng.

10. Tlhahlobo ea oli

Matla a dielectric:54.0 kV

Mongobo:11.2 mg / kg

Dissipation factor:0.00199%

Likahare tsa Furan: Ka tlase kapa ho lekana le 0.1

DGA: Tloaelehile

Boleng ba oli bo maemong a matle.

04 Ho paka le ho Romela

4.1 Ho paka

300 kva pad mounted transformer residential-export-packing
300 kva pad mounted transformer residential-wooden crate packaging
 

05 Sebaka le Kakaretso

300 kva pad mounted transformer residential-back-view

Transformer ena ea 300 kVA{1}}phase three phase-e etsetsoa Canada. E latela CSA C227.4:21. E sebelisa pholiso ea ONAN le ho kenya oli ea liminerale. Maqhubu a aluminium a etsa hore e sebetse hantle ebile e bobebe. Maoto a mahlano-a thusa ho boloka transformer e tsitsitse le ho fokotsa lerata. Tanka e tiisitsoeng e matla 'me e khona ho sebetsana le boemo ba leholimo bo ka ntle. Hape ha e na tamperproof ebile ho bonolo ho e hlokomela. Transformer e 'ngoe le e' ngoe e etsoa ka har'a workshop e hloekileng e nang le mehato e tiileng ea ho etsa bonnete ba hore boleng bo holimo. E sebetsa ka katleho ea 98.94% mme e na le tahlehelo e tlase. E fana ka matla a tsitsitseng bakeng sa basebelisi ba khoebo, ba bolulo le ba liindasteri tse nyane.

 

Hot Tags: pad mounted transformer bolulo, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry