1.25 MVA Cast Resin Mofuta oa Transformer-0.415 / 3.3 * 6.6 kV|Malaysia 2025

1.25 MVA Cast Resin Mofuta oa Transformer-0.415 / 3.3 * 6.6 kV|Malaysia 2025

Naha: Malaysia 2025
Matla: 1000/1250 kVA
Matla: 0.415-3.3/6.6 kV+2*10% kV
Feature: e nang le kampetsoeng le mabili
Romela Inquiry

 

 

1.25 MVA cast resin type transformer

E Eketsetsoe Bokhabane - Resin Cast Dry Type Transformer, Ts'ebetso e Phahameng!

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

1000/1250 kVA resin cast dry type transformer e ile ea isoa Malaysia ka 2025. Matla a lekantsoeng a transformer ke 1000/1250 kVA e nang le pholiso ea ONAN/ONAF. Matla a mantlha ke 0.415d kV, motlakase oa bobeli ke 3.3/6.6+2*10% kV (3.3/3.63/3.96 kapa 6.6/7.26/7.92 kV) ka ±2*10% tapping range (NLTC), ba thehile sehlopha sa vector sa Yd11.

Re hlahisa-sebelisoa sa rona sa 1000/1250kVA se ommeng{3}}se feto-fetohang, se etselitsoeng liteko tse tšepahalang tsa enjene le lisebelisoa tsa motlakase tsa indasteri. Yuniti ena e matla e na le lisebelisoa tse feto-fetohang tsa 0.415-3.3/6.6kV tse nang le ±2×10% no{10}}bokhoni ba ho fetola theipi le ho khetha 3.3kV/6.6kV bakeng sa ho feto-fetoha ha motlakase.

Kaho ea resin e sa sebetseng ea lelakabe-e netefatsa polokeho e holimo ntle le likotsi tsa mollo kapa ho lutla, ha lifenehi tse kopaneng tse futhumatsang le ho beha leihlo mocheso li boloka tšebetso e nepahetseng ea mocheso. Transformer ena e ka har'a sebaka se sirelelitsoeng se nang le mabili a tsamaeang, 'me e kopanya boemo ba indasteri-e tšoarellang habonolo.

E nepahetse bakeng sa tikoloho e boima joalo ka lisebelisoa tsa tlhahlobo ea makoloi, ts'ebetso ea merafo, le lisebelisoa tsa matla a ka nchafatsoang, tlhokomelo ea rona-e fana ka tharollo ea mahala e fana ka taolo e nepahetseng ea motlakase, ho tšepahala ka mokhoa o ikhethang, le khotso ea kelello e felletseng bakeng sa litlhoko tsa hau tsa -motlakase o phahameng.

 

 

 

1.2 Tlhaloso ea Setsebi

1000/1250 kVA resin e entsoeng ka mokhoa o omileng oa sefetoleli le leqephe la data

E fetisetsoa ho
Malaysia
Selemo
2025
Mofuta
Resin cast omileng mofuta oa transformer
Boitsebiso ba mantlha
Letlapa la tšepe la silicon le entsoeng ka lijo-thollo
Standard
IEC60076
Rated Power
1000/1250kVA
Khafetsa
50HZ
Mokhahlelo
Boraro
Sehlopha sa Vector
Yd11
Mofuta oa ho Pholisa
ONAN/ONAF
Voltage ea mantlha
0.415d kV
Motlakase oa bobeli
3.3/6.6+2*10%Y kV
Lintho Tse Hlahang
Koporo
Tšitiso
6%
Tlanya Changer
NLTC
Tlanya Range
±2*10%@voltage ea bobeli
Ha ho Tahlehelo ea Mojaro
1.65KW
Ho Lahleheloa ke Moroalo
8.8 KW
Boemo ba insulation
F

 

 

1.3 Litšoantšo

1000/1250kVA resin e entsoeng ka setšoantšo sa setšoantšo se omileng sa transformer le boholo.

1.25 MVA cast resin type transformer diagram 1.25 MVA cast resin type transformer diagram

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Transformer ena ea resin cast e na le silicon steel laminated core e nang le manonyeletso a khopameng a 45℃le epoxy binding, e fokotsang-tahlehelo ea mojaro ka 20% ha e bapisoa le maemo. Ka matlafatso ea 1.65-1.72T flux density, Ka tlase ho kapa ho lekana le ho phahama ha mocheso oa 75K (Sehlopha sa F), 'me Ka tlase ho kapa ho lekana le lerata la 55dB, e nepahetse bakeng sa lits'ebetso tse boima joalo ka tlhahlobo ea enjine, ho netefatsa hore 20+ e sebetsa ntle le ho lokisoa ka lilemo tse ngata.

 

2.2 Ho tsubella

copper conductors winding

Transfer e sebelisa li-conductors tse phahameng- tsa koporo tse hloekileng tse nang le-li-layer insulation' tse ngata, tse netefatsang ts'ebetso e ntle haholo ea motlakase le mochini. HV winding e sebelisa karolo e tsoelipanang bakeng sa ho tsamaisa motlakase hantle, ha LV winding eona e sebelisa sebopeho sa foil bakeng sa{3}}motlako o matlafalitsoeng oa ho thibela motlakase.

E kenngoe ke vacuum{{0}cast epoxy resin, matsoelintsoeke a theha sistimi e tiileng le e tsamaisang mocheso, e hanyetsanang le mongobo, lerōle, le ho tsoa ka mokhoa o itseng. Thermal conductivity e phahameng ea resin, e kopantsoeng le e hahelletsoeng-ka har'a likotopo tse pholisang le lifene, e netefatsa ho phahama ho tsitsitseng ha mocheso le bokhoni ba ho tlala haholo.

 

2.3 Kopano ea ho Qetela

Transformer e na le moralo oa kopano, e kopanyang vacuum{{0}cast epoxy windings e nang le{1}}mehato e phahameng ea silicon cores, e sirelelitsoeng ka insulating spacers le clamping mechanisms. E na le sesebelisoa sa ho tima-load tap changer (±2×10%) le khetho ea voltage ea 3.3kV/6.6kV, e kenyelletsa taolo e bohlale ea mocheso le ho qobelloa-ho pholisa moea. Libaka tseo u ka li khethang tsa IP20 li fana ka tšireletso e matla, li fana ka tšireletso e matla, tse thibelang ho sisinyeha, ho hlokomela{11}}tšebetso ea mahala le lerata le tlase.

1000kva cast resin type transformer

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Tekanyo ea ho hanyetsa matsoelintsoeke

/

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane

Khanyetso ea mela: e ka tlase ho kapa e lekana le 2%

HV (mohala)

LV (mohala)

Feta

0.96%

0.68%

0.25%

2

Tekanyo ea karo-karolelano ea motlakase le ho hlahloba phallo ea mohato

/

Mamello ea karo-karolelano ea motlakase ho theipi ea mantlha: ± 1/10

Letšoao la khokahano: Yd11

-0.26% ~ 0.15%

Yd11

Feta

3

Tekanyo ea Che{0} ea Tahlehelo ea Mojaro le ea Hona Joale ho 90%, 100% le 110% ea matla a matla a motlakase.

/

kW

I0 :: fana ka boleng bo lekantsoeng

P0: fana ka boleng bo lekantsoeng

90%Ur

100%Ur

110%Ur

Feta

0.27

1.395

0.30

1.551

0.33

1.706

4

Litahlehelo tsa Meroalo, Impedans Voltage

/

kW

kW

T:120 likhato

Z%: boleng bo lekantsoeng

Pk: boleng bo lekantsoeng

Pt: boleng bo lekantsoeng

6.06%

6.173

8.148

Feta

5

Teko ea Voltage e sebelisitsoeng

/

HV: 20kV 60s

LV: 3kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

6

Teko ea ho mamella Voltage e kentsoeng

/

Matla a sebelisoang (kV):

2 Ur

Matla a susumetsoang (kV): 0.83

Nako:40

Hangata (HZ): 150

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea Phallo e sa Feleng

pC

Boemo bo phahameng ba ho tsoa ha karolo e itseng e tla ba 10 pC

<10

Feta

 

cast resin type transformer testing
1000kva cast resin type transformer routine test

 

 

04 Ho paka le ho Romela

resin cast dry-type transformer packing
resin cast dry-type transformers delivery

05 Sebaka le Kakaretso

SCOTECH Resin Cast Dry-Type Transformers e behile litekanyetso tse ncha ka tlhokomelo-tšebetso ea mahala, matla a phahameng a dielectric, le bophelo ba nako e telele.

Ho tloha litsing tse thata tsa indasteri ho isa lits'ebetsong tse bohlale tsa grid, tlhahiso ea rona ea ISO-e netefalitsoeng le litharollo tse ikhethileng li fana ka phetolo ea motlakase e bolokehileng, e sebetsang hantle le e tšoarellang. Ikopanye le sehlopha sa rona sa boenjiniere kajeno bakeng sa tharollo ea hau ea matla e lokiselitsoeng!

cast resin type transformer with enclosure and wheels

 

Hot Tags: lahla mofuta oa resin transformer, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry