2500 kVA Dry Transformer-10/0.4 kV|Georgia 2025

2500 kVA Dry Transformer-10/0.4 kV|Georgia 2025

Naha: Georgia 2024
Matla: 2500kVA
Matla: 10/0.4kV
Feature: e nang le taolo ea mocheso
Romela Inquiry

 

 

2500 kva dry transformer

Resin Cast Dry Type Transformer - Kgetho bakeng sa Sebetsa, Sireletsehile, le Eco{1}}Tsamaiso ya Phetiso ya Motlakase!

 

01 Kakaretso

1.1 Semelo sa Morero

The 2500 kVA resin cast mofuta o omileng transformer e ile ea isoa Georgia ka 2024, matla a lekantsoeng a transformer ke 2500 kVA. Matla a phahameng a motlakase oa mofuta ona o omileng ke 10kV, matla a tlaase ke 0.4kV. Transformer ena e phahameng ea motlakase ea mofuta o omileng e na le mochine o sa fetoleng mojaro oa pompo, sebaka sa ho pompong ke ± 2 * 2.5% ka lehlakoreng la mantlha, pholileng ke KNAN/KNAF.

Li-transformer tsa mofuta o omileng oa resin li emela sehlohlolong sa theknoloji ea sejoale-joale ea li-transformer, tse kopanyang ts'ebetso ea motlakase ka bokhabane le ho tiea ho matla ha mochini. Mohaho o mocha o kenyelletsa ho kenya mapheo ka khetla e tiileng ea epoxy, e sa ntlafatseng feela ho tšoarella ha transformer empa hape e fana ka khanyetso e ikhethang khahlano le maemo a tikoloho joalo ka mongobo, lerōle le ho fetoha ha mocheso. Karolo ena e ikhethang e netefatsa hore li-transformer tsa mofuta o omileng oa resin li boloka ts'ebetso e nepahetseng maemong a fapaneng a phephetso, e leng se etsang hore e be tse loketseng ho sebelisoa lits'ebetsong tse fapaneng tsa indasteri.

Ho feta moo, li-transformer tsena li etelletsa pele polokeho ka ho felisa kotsi ea ho lutla ha oli le ho fokotsa likotsi tsa mollo, e leng monyetla o moholo libakeng tsa litoropo tse nang le baahi ba bangata le litsing tsa indasteri. Ho kenngoa ha tsona ho hloka tlhokomelo e fokolang ha ho bapisoa le li-transformer tsa khale- tse tlatsitsoeng ka oli, e leng ho isang litšenyehelong tse tlase tsa ts'ebetso ha nako e ntse e ea.

Ntle le matla a bona a tekheniki, li-transformer tsa mofuta o omileng oa resin li fana ka tlhoko e ntseng e hola ea tharollo ea moshoelella lekaleng la matla. Moralo oa bona o lumellana le maemo a tikoloho, o kenya letsoho ho fokotseng likhase tsa khabone le ho ts'ehetsa merero ea ts'ebetso ea liindasteri tse fapaneng. Ebang ke bakeng sa merero ea matla a tsosolositsoeng, meaho ea khoebo, kapa ts'ebetso ea indasteri, li-transformer tsa mofuta oa resin cast ke khetho e bohlale bakeng sa mekhatlo e batlang ho ntlafatsa meaho ea eona ea motlakase ha e ntse e khothaletsa boikarabello ba tikoloho.

 

 

1.2 Tlhaloso ea Setsebi

2500 kVA resin e entsoeng ka mokhoa o omileng oa sefetoleli le leqephe la data

E fetisetsoa ho
Georgia
Selemo
2024
Mofuta
Resin cast omileng mofuta oa transformer
Boitsebiso ba mantlha
Letlapa la tšepe la silicon le entsoeng ka lijo-thollo
Standard
IEC60076-11, EN50541-1, ISO9001, ISO14001
Rated Power
2500kVA
Khafetsa
50 HZ
Sehlopha sa Vector
Dyn11
Mokhahlelo
Boraro
Mofuta oa ho Pholisa
KNAN/KNAF
Voltage ea mantlha
10 kV
Motlakase oa bobeli
0.4 kV
Lintho Tse Hlahang
Aluminium
Tšitiso
6%
Tlanya Changer
NLTC
Tlanya Range
± 2*2.5% @ motlakase oa mantlha
Ha ho Tahlehelo ea Mojaro
3.2KW
Ho Lahleheloa ke Moroalo
19KW
Boemo ba insulation
F

 

1.3 Litšoantšo

2500 kVA resin e entsoeng ka setšoantšo sa setšoantšo se omileng sa transformer le boholo.

2500 kva dry transformer drawing 2500 kva cast resin type transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Koko ea resin{{0}cast dry{1}} mofuta oa transformer e bohlokoa bakeng sa ts'ebetso ea eona, tšebeliso ea matla le botsitso ba ts'ebetso. E entsoe ka-a batang haholo-ka lishiti tsa silicon tse rolisitsoeng, konokono e na le likarolo tse nepahetseng tsa 45℃mitred cuts le mohato-mohaho o matlafatsang matla a khoheli le ho fokotsa tahlehelo le lerata. -mesebetsi ea ho lahlela resin e matlafatsa matla a eona a ho sebetsa le ho thothomela, ho netefatsa ts'ebetso e matla.

Bohareng bo tlositsoe ka corrosion{0}}resistant epoxy resin ho sireletsa khahlanong le mongobo le oxidation, ha mechato e sebetsang hantle ea ho felisa mocheso e thibela ho futhumala ho feteletseng, ho boloka ts'ebetso ea nako e telele-. Ho sebelisa li-automation tse tsoetseng pele indastering ho netefatsa boleng bo tsitsitseng le ho nepahala. Ka lebaka la tahlehelo ea matla a tlase, lerata le fokolang haholo, ha e senyehe, le nako ea ts'ebeletso e atolositsoeng, moralo ona oa mantlha o emela{4}}boenjiniere ba morao-rao bakeng sa litsamaiso tsa sejoale-joale tsa motlakase.

cast resin transformer silicon electrical steel sheet

 

2.2 Ho tsubella

2500kva cast resin type transformer winding

Li-winding tse tlase tsa motlakase li entsoe ka koporo ea foil kapa maqephe a aluminium, a kentsoeng ka likarolo tse ngata. Sebopeho sa bona sa helical se fana ka botsitso bo babatsehang nakong ea lipotoloho tse khutšoanyane le ho fokotsa tahlehelo ho tloha "phello ea letlalo."

Maqhubu a matla a phahameng a na le mehala ea koporo e pota-potileng kapa ea aluminium e entsoeng ka enameled, e entsoeng ke motlakase oa motlakase. Li na le meaho e mengata-e nang le li-layer helical-e nang le insulation ea boleng bo holimo (sehlopha sa F kapa H), e netefatsang hore e tšoarella tlas'a{3}}maemo a phahameng a motlakase.

 

2.3 Tse ling

Maqhubu a fetisetsoa phaposing ea vacuum casting bakeng sa ho etsa epoxy resin. Ka mor'a ho futhumatsa pele ho tlosa mongobo le likhase, lisebelisoa tsa lik'hemik'hale tse kang epoxy resin le harderner li lokisoa ka lijaneng tse arohaneng. Hang ha e se e loketse, lisebelisoa tsena li tsoakoa ka motsoako o tsitsitseng ka tekanyo e nepahetseng ebe li kenngoa ka har'a hlobo. Likhoele li phekoleha ka ontong ka mocheso o phahameng ho theha meaho e tiileng e tiileng.

epoxy resin winding

 

2.4 Kopano ea ho Qetela

cast resin dry type transformer final assembly

Kopano ea Joko e ka Holimo le e Tlase: Sireletsa lijoko tse ka holimo le tse ka tlaase ho setsi sa transformer, ho netefatsa botsitso le ts'ebetso ea motlakase.

Lihokelo tsa Motlakase: Theha likhokahano tsa motlakase lipakeng tsa-voltage tse phahameng le tse tlase{1}}maemelo a matla a motlakase, ho etsa bonnete ba hore likhokahano li sireletsehile 'me li finyella litlhoko tsa moralo.

Seboka sa Motlatsi: Kenya lisebelisoa, tse kang li-controller tsa mocheso, li-surge arrestors joalo-joalo, ho netefatsa botšepehi le ts'ebetso ea kakaretso ea mohaho.

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Tekanyo ea ho hanyetsa matsoelintsoeke

/

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane

Khanyetso ea mela: e ka tlase ho kapa e lekana le 2%

HV (mohala)

LV (mohala)

Feta

 

0.05%

1.69%

2

Tekanyo ea karo-karolelano ea motlakase le ho hlahloba phallo ea mohato

/

Mamello ea karo-karolelano ea motlakase ho theipi ea mantlha: ± 1/10

Letšoao la khokahano: Dyn11

-0.11% ~ 0.24%

Dyn11

Feta

 

3

Tekanyo ea -nako e Khutšoane ea Impedance le Loss Loss

/

kW

kW

T:120 likhato

Z%: boleng bo lekantsoeng

Pk: boleng bo lekantsoeng

Pt: boleng bo lekantsoeng

6.21%

13.883

17.849

Feta

 

4

Tekanyo ea Ha ho-Tahlehelo ea Mojaro le Hona Joale ho 90% le 110% ea matla a matla a motlakase

/

kW

I0 :: fana ka boleng bo lekantsoeng

P0: fana ka boleng bo lekantsoeng

90% Ur

0.207

2.683

Feta

 

100% Ur

0.23

2.982

110% Ur

0.253

3.280

5

Teko ea Voltage e sebelisitsoeng

/

HV: 28kV 60s

LV: 3kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

 

6

Teko ea ho mamella Voltage e kentsoeng

/

Matla a sebelisoang (KV):

2 Ur

Matla a susumetsoang (KV): 0.8

Nako:40

Hangata (HZ): 150

Ha ho ho putlama ha motlakase oa liteko

Feta

 

7

Teko ea Phallo e sa Feleng

pC

Boemo bo phahameng ba ho tsoa ha karolo e itseng e tla ba 10 pC

<10

Feta

 

 

dry transformer testing
cast resin dry type transformer testing

 

 

04 Ho paka le ho Romela

dry transformer packing
dry transformer shipping

 

 

05 Sebaka le Kakaretso

Qetellong, resin cast dry-mofuta oa transformer ke tharollo ea boenjiniere ba motlakase, e fanang ka ts'ebetso e tšepahalang le e ntle bakeng sa litsamaiso tsa sejoale-joale tsa kabo ea motlakase. Ka moralo oa eona o matla, ho kenya letsoho ho phahameng, le likarolo tse tsoetseng pele tsa polokeho, li-transformer tsa rona li hahiloe ho mamella mathata a tikoloho e boima ha li ntse li netefatsa taolo e sebetsang ea matla. Ka ho khetha li-resin cast dry-mofuta oa li-transformer, u tsetela ho fumana tharollo e tšoarellang{4}ea boleng bo holimo e matlafatsang ts'ebetso le polokeho ea lisebelisoa tsa hau tsa motlakase. Fumana melemo ea theknoloji ea rona e tsoetseng pele 'me u phahamise lisebelisoa tsa hau tsa motlakase ka khetho e tšepahalang le e sebetsang.

dry transformer

 

Hot Tags: transformer e omileng, moetsi, mofani oa thepa, theko, litšenyehelo