630 kVA Dry Type Step Down Transformer-11/0.55 kV|Afrika Boroa 2024

630 kVA Dry Type Step Down Transformer-11/0.55 kV|Afrika Boroa 2024

Naha: Afrika Boroa 2024
Matla: 630kVA
Matla: 11/0.55kV
Feature: e nang le taolo ea mocheso
Romela Inquiry

 

 

630 kVA dry type step down transformer

Ho pholile hantle, ho hlokomeloa ka mokhoa o fokolang-VPI Dry-Type Transformer eo u ka e tšepang.

 

01 Kakaretso

1.1 Semelo sa Morero

Transformer ea 630 kVA e bulang matsoelintsoeke ea mofuta o omileng e ile ea isoa Afrika Boroa ka 2024. Matla a lekantsoeng a 630 kVA e nang le pholiso ea AN/AF, motlakase oa mantlha ke 11 kV le ±2 *2.5% tapping range (NLTC), motlakase oa bobeli ke 0.55kV, ba thehile sehlopha sa vector ea Dyn11.

Sebopeho sa ho lahla fiber ea khalase se sa tlatsoang se ka fihlella maqhubu a matla a tšoanang le boemo ba tšusumetso joalo ka -sefetoleli se qoelitsoeng ka oli. Transformer ena ea mofuta oa cast e khonne ho mamella matla a teko (maqhubu a phahameng ho isa ho matla a phahameng, matla a phahameng ho ea tlase ho tlase) le motlakase o sebetsang tikolohong ea sepakapaka. Ho na le phapang e nyane feela ea khatello pakeng tsa ho phethoha, likarolo le likarolo tsa matsoelintsoeke, tse tsamaisoang ke resin ka boeona mme e fihla boemong bo sireletsehileng haholo. Matla a pakeng tsa lera la foil-a maqeba a maqeba a manyane haholo ha a thinya, moo matsoelo a fellang teng ha a na spiral Angle, sebaka sa ho lutla sa makenete se senyenyane, 'me axial short resistance{5}e matla.

 

1.2 Tlhaloso ea Setsebi

Tlhaloso ea 630 kVA ea mofuta o omileng oa transformer le leqephe la data

E fetisetsoa ho
Afrika Boroa
Selemo
2024
Mohlala
630kVA-11/0.55kV
Mofuta
Ho bula sefetoleli sa mofuta o omileng o omileng
Standard
IEC60076
Rated Power
630kVA
Khafetsa
50HZ
Mokhahlelo
3
Mofuta oa ho Pholisa
AN/AF
Voltage ea mantlha
11kV
Motlakase oa bobeli
0.55 kV
Lintho Tse Hlahang
Aluminium
Li-fans tse pholisang
E kentsoe ka tlase ho mochini oa ho qala / ho emisa koloi e laoloang ke molaoli oa mocheso, 110V ea motlakase oa motlakase.
Tšitiso
6%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%@lehlakoreng la mathomo
Ha ho Tahlehelo ea Mojaro
1.25KW
Ho Lahleheloa ke Moroalo
6.5KW
Lisebelisoa
Tlhophiso e Tloaelehileng
Boemo ba insulation
H
Mabone a motheo a mamellana le -lehlakore la mantlha (BIL)
75 kV
Maqhubu a motlakase a mamellang -karolo ea mantlha
35 kV
Mabone a motheo a mamellana le motlakase-ka lehlakoreng la bobeli (BIL)
/
Motlakase o mamella voltage{0}}ka lehlakoreng la bobeli
3 kV
Mocheso oa moea o phahama @ boemo bo lekantsoeng ba ts'ebeletso
100K

 

1.3 Litšoantšo

630 kVA e bula sets'oants'o sa sebopeho se omileng sa mofuta o omileng le boholo.

630 kVA dry type step down transformer diagram

 

02 Tlhahiso

2.1 Konokono

Karolo ea mantlha ea transformer e omeletseng ke ho theha potoloho ea makenete. Bakeng sa ho fokotsa tahlehelo ea hona joale ea eddy, mantlha e entsoe ka letlapa le tšesaane la silicon le thekesela. Bokaholimo ba lakane ea tšepe ea silicon e koahetsoe ka pente e sireletsang 'me e entsoe ka oxidized ho etsa lera le sireletsang. Moko oa mantlha o entsoe ka 'mele oa mantlha oa tšepe, li-fasteners le likarolo tsa insulating.

Li-fasteners le likarolo tsa insulating li entsoe ka clamp, screw, theipi e tlamang ka khalase, tepi e tlamang ea tšepe, pad le clamp insulation, pipe ea insulation le pad ea ho pata, sekoti sa fatše le leoto.

630 kVA dry type step down transformer iron core

 

2.2 Ho tsubella

630 kVA dry type step down transformer winding

Vacuum casting e ka fumana sebopeho se ts'oanang sa insulation, ho tlosa li-bubble le li-voidings, 'me ho qoba ho tsoa ka mokhoa o sa fellang ka har'a matsoelintsoeke: foil matsoelintsoeke pakeng tsa mekhahlelo e tlase gagamalo, e ke ke ea baka ho tsoa ka mokhoa o itseng. Ho latela IEC60076, liteko tse sa fellang li lokela ho etsoa ho transformer e kopaneng ka botlalo. E le ho netefatsa hore moralo le tlhahiso li na le boemo ba boleng bo holimo, liteko tse sa fellang tsa ho ntša metsi li etsoa ho e 'ngoe le e' ngoe e phahameng ea motlakase pele ho kopano. Ka tsela ena, o ka lekola hore na ho kenella ka har'a moea o phahameng oa voltage ho fihlela litlhoko tsa boleng. Matla a ho felloa ke matla a sa fellang ke bonyane makhetlo a 1.2 a matla a lekantsoeng, 'me maemong a mangata, esita le makhetlo a 2 a matla a lekantsoeng. Ka tlhahlobo ena, ho netefalitsoe hore ha ho na bothata ho tsoa sebakeng sa heno.

 

2.3 Sistimi ea taolo ea mocheso

1. E hahiloe ka-ka PT100 probes ka 3-mohato oa li-winding ho bona mocheso oa nako ea sebele oa li-winding le mocheso oa potoloho skrineng sa dijithale.

2. Potoloho ea alamo e bulehileng le pontšo ea alamo ea ho itlhahloba ka phoso le tlhahiso

3. 3-liketso tsa mothating:

a. Ha mocheso o fihla ho boleng bo behiloeng, li-fan tse pholileng li qala ka bo eona sethaleng sa 1st

b. Alamo e phahameng ea mocheso sethaleng sa 2nd

c. Leeto la mocheso ho feta sethaleng sa 3

4. Fan manual / auto control switch

5. Fans nako ea ho qala / emisa

6. Rekoto ea data ea nalane le tlhahiso

7. Matla a matla a matla a 110V

630 kVA dry type step down transformer temperature control system

 

2.4 Kopano ea ho Qetela

630 kVA dry type step down transformer final assembly

Ts'ebetso ea kopano

1. Kopano ea lisebelisoa: Pele ho tsohle, ho bokelloa ha lisebelisoa, ho kenyelletsa le kopano ea mantlha, ho itšehla thajana, ho pota-pota, joalo-joalo.

2. Etsa qeto ea sebaka sa sesebelisoa: Etsa qeto ea sebaka sa sesebelisoa ho latela litlhoko tsa sebele ho netefatsa hore sesebelisoa se ka bokelloa hantle.

3. Lokisetsa likarolo tsa ho kopanya: E le ho netefatsa ts'ebetso e tloaelehileng ea lisebelisoa tsohle, ho hlokahala ho lokisetsa likarolo tse sa tšoaneng tsa ho kopanya esale pele, ho akarelletsa le li-gaskets, bolts, washers, li-gaskets tsa selemo, joalo-joalo.

4. Bokella motho ea itšehlang thajana: Ntlha ea pele, bokella sekhetho, ho kenyelletsa le kopano ea foreimi ea ho itšehla thajana, khetla ea ho itšehla thajana, poleiti ea isolator, karohano, joalo-joalo.

5. Kopanya matsoelo a matsoelintsoeke: Kenya sebaka sa matsoelintsoeke ka har'a sesebelisoa, 'me u ele hloko boleng ba lisebelisoa tsa ho koala, hammoho le taolo e nepahetseng ea bolelele ba matsoelo,{1}}karolo ea karolo le likarolo tse ling.

6. Kenya sehokelo: Kopanya sesebelisoa ho ea ka sehokelo se lokiselitsoeng ho lokisa le ho sireletsa sesebelisoa.

7. Phekolo ea ho itšireletsa: E le ho etsa bonnete ba hore lisebelisoa li sebetsa ka mokhoa o sireletsehileng, ho hlokahala hore u etse phekolo ea ho itšireletsa, e kang ho roala pente e sireletsang le ho roala thepa ea ho itšireletsa.

8. Netefatsa sesebelisoa: Netefatsa sesebelisoa ho hlahloba hore na lisebelisoa tsa lisebelisoa li finyella litlhoko.

9. Tlhahlobo ea feme: Tlhahlobo ea ho qetela ea fektheri ho netefatsa ts'ebetso e tloaelehileng ea lisebelisoa.

 

 

03 Teko

1. Tekanyo ea ho hanyetsa li-insulation: Bakeng sa moea o mong le o mong oa transformer e omeletseng, tekanyo ea ho hanyetsa mocheso e hlokahalang. Sena se ka hlahloba hore na thepa ea ho kenya letsoho e kopana le litlhoko tse tloaelehileng.

2. Tekanyo e ikhethang ea Volt-ampere: Volt-ampere character measurement ke teko ea ho lekola potoloho e khuts'oane le potoloho e bulehileng ea mapheo 'ohle a mofuta o sekete oa transformer. Ka nako e ts'oanang, e ka boela ea lekanya boemo ba eona bo reriloeng, tahlehelo ea mojaro, ha ho{4}tahlehelo ea mojaro le litšobotsi tsa taolo ea motlakase.

3. Teko ea matla a ho itšireletsa: Teko e hlahloba ho hanyetsa ha motlakase oa thepa ea ho pata, 'me e lekanya matla a ho itšireletsa a transformer ka teko ea khatello.

4. Tekanyo e feto-fetohang ea tekanyo: Tekanyo ea tekanyo e feto-fetohang ke teko ea ho hlahloba litšobotsi tsa phetisetso ea mofuta o sekete oa transformer. Sena se ka hlahloba hore na karo-karolelano ea transformer e tsitsitse tlas'a maemo a fapaneng a mojaro.

5. Teko ea potoloho e khutšoanyane: Teko ea potoloho e khutšoanyane ke teko ea ho lekanya tahlehelo e omileng ea transformer le ho phahama ha mocheso. Sena se thusa ho hlahloba hore na transformer e sebetsa hantle tlas'a maemo a khutšoanyane a potoloho.

6. Teko ya botshepehi ba mochini: Teko e lekola-mofuta o omileng oa ho khona ho mamella khatello ea maikutlo. Palo ea ho falla ha axial le ho kheloha ho bakoang ke ho sotha le torque li lekanngoa ka ho sebelisa matla.

 

630 kVA dry type step down transformer test

 

04 Ho paka le ho Romela

630 kVA dry type step down transformer packing
630 kVA dry type step down transformer shipping

05 Sebaka le Kakaretso

Rea leboha ka thahasello ea hau ho VPI dry{0}type transformers! Lihlahisoa tsa rona li tumme ka ts'ebetso ea tsona e ikhethang, boleng bo tšepahalang, le boqapi bo loketseng-le tikoloho, e ikemiselitseng ho fana ka litharollo tsa motlakase tse sebetsang hantle le tse sireletsehileng liindastering tse fapaneng. Ebang ke tsa liindasteri, meaho ea khoebo, kapa litlhoko tse khethehileng, li-transformer tsa mofuta oa VPI-ke khetho ea hau e tšepahalang kamehla. Re labalabela ho sebetsa le uena ho tsamaisa bokamoso bo tsitsitseng hammoho. Bakeng sa tlhaiso-leseling e batsi kapa tšehetso ea motho ka mong, ka kopo ikutloe u lokolohile ho ikopanya le sehlopha sa rona sa litsebi!

630 kVA dry type step down transformers

 