1000 kVA Dead Front Transformer-24/0.48 kV|Sebelisa 2024
Matla: 1000kVA
Matla: 24000 D-480Y/277 V
Tšobotsi:ka ho kenya feedthru

1000 kVA e shoeleng-pad e ka pele-transformer e kentsoeng - e bolokehile, e sebetsa hantle, 'me e hahiloe bakeng sa kabo ea motlakase e tšepahalang maemong afe kapa afe.
01 Kakaretso
1.1 Tlhaloso ea Morero
E isitsoe USA ka 2024, 1000 kVA enatse tharo-pase ea mekhahlelo-e kentsoeng ka transformere lumellana le IEEE Std C57.12.34-2022 mme e kopana le maemo a sebetsang hantle a matla a DOE 2016. E sebetsa ho 60 Hz ka motlakase o ka sehloohong oa 24 kV le motlakase oa bobeli oa 480GrdY / 277 V, o nang le sehlopha sa li-vector Dyn1. Transformer e sebelisa maqhubu a koporo le ho pholile ha KNAN, 'me e tletse oli ea ester ea tlhaho ea FR3 ho matlafatsa tšireletso ea mollo le ho boloka tikoloho. E na le tšebetso ea loop feed, e shoeleng-ka pele, le{16}}ha ho na{16}}changer ea ho roala thepa e fanang ka mefuta e fapaneng ea taolo ea voltage ea ±2 × 2.5%, yuniti e na le 5.75% impedance, ha ho{18}tahlehelo ea 1.020 kW, le tahlehelo e sebetsang ea{20,8,07} kabo ea matla a mahareng.
Transformer e shoeleng ea 1000 kVA e fokotsa kotsi ea arc flash nakong ea ts'ebetso kapa tlhokomelo. Mohaho oa eona o ka pele o shoeleng o kenyelletsa lihlahla tsa rabara tse sirelelitsoeng ka botlalo, tse emisitsoeng ka matsoele a mangata, ho netefatsa polokeho e ntlafetseng le boiketlo ba khokahano.
1000 kVA dead pad Mount transformer e sebetsa e le tharollo ea motlakase e sebetsang hantle bakeng sa ts'ebeliso, khoebo le indasteri. E etselitsoe hore e tšoarelle nako e telele, e ka kenngoa kahare le kantle, e fana ka sistimi e tšepahalang le e bolokehileng ea kabo ea matla libakeng tse fapaneng.
1.2 Tlhaloso ea Setsebi
Tlhaloso ea 1000kVA ea mekhahlelo e meraro e shoeleng ka pele le leqephe la data
|
E fetisetsoa ho
usa
|
|
Selemo
2024
|
|
Mofuta
Transformer ea mekhahlelo e meraro
|
|
Standard
IEEE Std C57.12.34-2022
|
|
Rated Power
1000 kVA
|
|
Khafetsa
60HZ
|
|
Fepa
Loop
|
|
Pele
E shoeleng
|
|
Mokhahlelo
Boraro
|
|
Mofuta oa ho Pholisa
KNAN
|
|
Mokelikeli o thibelang metsi
Oli ea FR3
|
|
Voltage ea mantlha
24 kV
|
|
Motlakase oa bobeli
0.48 kV
|
|
Sehlopha sa Vector
Dyn1
|
|
Lintho Tse Hlahang
Koporo
|
|
Tšitiso
5.75%
|
|
Maemo a Sebetsang le Tahlehelo
DOE 2016
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
1.020 kW
|
|
Ho Lahleheloa ke Moroalo
8.170 kW
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
1000kVA setafo sa sefetoleli se ka pele sa 1000kVA le nameplate
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa
Li-cores tsa SCOTECH li etsoa tlas'a taolo e tiileng ea boleng, ho netefatsa hore ho na le stacking e nepahetseng, khatello e tšoanang ea lamination, le ho lumellana ho tsitsitseng ha makenete. Ts'ebetso ena ka katleho e fokotsa likheo tsa moea le khatello ea mochine ka har'a mantlha, ho ntlafatsa botšepehi ba sebopeho le ho fokotsa kotsi ea libaka tse chesang.

2.2 Ho tsubella

E hahetsoe bakeng sa tšebeliso ea khoebo le liindasteri, transformer ena ea 1000 kVA Dyn1 e sebelisa likhoele tsa foil-leqeba la LV le lipampiri-li-HV tsa terata e insulated. Sebopeho se ntlafalitsoeng se tiisa ho ts'eptjoa ho ts'epahalang, lerata le tlase, le ho tšoarella ho matlafalitsoeng ka tlasa 24 kV ho kenya le maemo a fapaneng a mojaro.
2.3 Tanka
Tanka ea transformer e sireletsa likarolo tsa kahare ho ts'isinyeho ea mochini, ho thothomela le matla a kantle. Sebopeho sa eona sa tšepe se matlafalitsoeng se tiisa hore nakong ea lipalangoang le ho kenya, likarolo tsa bohlokoa li lula li sirelelitsoe hantle 'me li behiloe ka mokhoa o sireletsehileng.

2.4 Kopano ea ho Qetela

Scotech e hlomella transformer e 'ngoe le e 'ngoe ka Bay e ka hare-O{1}}Li fuse tse ngata ka ho latellana tse nang le-li-fuse tse fokotsang, tse boholo bo loketseng bakeng sa tšireletso e nepahetseng. Re fana ka lisebelisoa tsa MOV elbow{4}}type surge arrester tse kopanang le IEEE 386, tse netefatsang ts'ebetso e bolokehileng tlas'a maemo a ho buuoa.
03 Ho etsa liteko
Teko e Tloaelehileng le Tekanyetso ea Teko
1. Litekanyo tsa Resistance ho latela IEEE C57.12.90-2021 Clause 5
2. Mokhahlelo-Teko ea likamano ho latela IEEE C57.12.90-2021 Clause 6
3. Liteko tsa Karolelano ho latela IEEE C57.12.90-2021 Clause 7
4. Ha ho Tahlehelo ea Moroalo ebile ha ho na Mojaro Hona Joale ho latela IEEE C57.12.90-2021 Clause 8
5. Los Losses, Impedans Voltage and Efficiency ho latela IEEE C57.12.90-2021 Clause 9
6. Induced Voltage Withstand Test ho latela IEEE C57.12.90-2021 Clause 10.5.1
7. Applied Voltage Test ho latela IEEE C57.12.90-2021 Clause 10.6
8. Tlhahlobo ea ho Lutla ka Khatello ea Liquid Immersed Transformers - teko ea ho lutla ka 15 kPa e tla etsoa lihora tse 12 ntle le ho lutla. Ha ho deformation e sa feleng.
9. Tekanyo ea ho hanyetsa Insulation
10. Teko ea Dielectric ea Oli


Liphetho tsa liteko
|
Che. |
Ntho ea Teko |
Yuniti |
Melao ea ho Amohela |
Litekanyetso Tse Lekanyelitsoeng |
Qetello |
|
1 |
Litekanyo tsa ho hanyetsa |
% |
Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane |
0.356 |
Feta |
|
2 |
Liteko tsa karo-karolelano |
% |
Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5% Letšoao la khokahano: Dyn1 |
-0.02% |
Feta |
|
3 |
diteko- tsa dikamano |
/ |
Dyn1 |
Dyn1 |
Feta |
|
4 |
Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale |
% kW |
I0 :: fana ka boleng bo lekantsoeng P0: fana ka boleng bo lekantsoeng mamello ea ho se lahleheloe ke moroalo ke +0% |
0.18% 0.985 |
Feta |
|
5 |
Litahlehelo tsa tahlehelo ea matla a motlakase le katleho |
% kW kW |
T:85 likhato Z%: boleng bo lekantsoeng Pk: boleng bo lekantsoeng Pt: boleng bo lekantsoeng mamello bakeng sa impedance ke ± 7.5% mamello ea tahlehelo ea boima kaofela ke +0% Katleho e seng ka tlase ho 99.43% |
5.61% 7.740 8.725 99.46% |
Feta |
|
6 |
Teko ea Voltage e sebelisitsoeng |
kV |
HV: 40kV 60s LV: 10kV 60s |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
7 |
Teko ea ho mamella Voltage e kentsoeng |
kV |
Matla a sebelisoang (KV): 0.960 Nako:40 Hangata (HZ): 180 |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
8 |
Leakage Test |
kPa |
Khatello e sebelisitsoeng: 15kPA Nako: 12h |
Ha ho na leakage le che Tšenyo |
Feta |
|
9 |
Tekanyo ea ho hanyetsa Insulation |
GΩ |
HV{{0}LV ho ea fatše: LV-HV ho ea fatše: HV&LV ho ea fatše: |
2.51 2.60 3.88 |
/ |
|
10 |
Teko ea Dielectric ea Oli |
kV |
E kholo ho feta kapa e lekana le 40 |
52.0 |
Feta |
04 Ho paka le ho Romela
![]() |
![]() |
05 Sebaka le Kakaretso
Transformer e shoeleng ea 1000 kVA ea Scoteche etselitsoe tšebeliso e nepahetseng le e sebetsang ea - ea motlakase ka mokhoa o sebetsang hantle, molemong, khoebong le maemong a indasteri. E etselitsoe ho kopana le litekanyetso tsa matla tsa IEEE Std C57.12.34-2022 le DOE 2016, transformer ena e na le mapheo a koporo, pholileng ea KNAN, le oli ea ester ea tlhaho ea FR3 bakeng sa tšireletso e ntlafetseng le tlhokomelo ea tikoloho. Moralo oa eona o shoeleng o nang le lihlahla tse sirelelitsoeng ka botlalo le litsoele tse robehileng o fokotsa haholo kotsi ea arc flash nakong ea ts'ebetso le tlhokomelo.
E hahiloe ka mokhoa o nepahetseng-li-cores tse pakiloeng le foil e ntlafalitsoeng-wound LV le pampiri{2}}likhoele tsa HV tse insulated, e tiisa hore e tšoarella nako e telele le lerata le tlase tlas'a meroalo e sa tšoaneng. Tanka e matla ea tšepe e sireletsa likarolo tsa bohlokoa ho tloha lits'oants'o le ho thothomela nakong ea lipalangoang le ho kenya. E na le Bay{5}}O-Li-fuse tsa morao-rao le tsa hajoale-tse fokotsang li-fuse hammoho le li-mov surge arrester tse lumellanang le IEEE 386, transformer ena e shoeleng e fana ka tšireletso e tiileng le ts'ebetso e tšepahalang.
Ho Scotech, re tsepamisitse maikutlo ho faneng ka li-transformer tse sebetsang, tse bolokehileng, le tse tšoarellang tse lekanang libaka tse fapaneng-ka ntle kapa ka ntle-tse matlafatsang tšebetso ea hau ka kholiseho le khotso ea kelello.

Hot Tags: e shoeleng ka pele transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
225 kVA Pad Mount Transformer-34.5/0.208 kV|USA 2024
300 kVA Pad Mount Transformer-12.47/0.48 kV|USA 2024
500 kVA Dead Pad Mounted Mounted Transformer-24.94/0...
1000 kVA Residential Pad Mounted Transformer-22.86/0...
1500 kVA Pad Mounted Transformer-34.5/0.48 kV|Sebeli...
1500 kVA Mount Transformer-22.86 / 0.208 kV|USA 2024
Romela Inquiry