630 kVA Three Phase Dry Type Transformer-10/0.4 kV|Georgia 2025

630 kVA Three Phase Dry Type Transformer-10/0.4 kV|Georgia 2025

Naha: Georgia 2024
Matla: 630 kVA
Matla: 10/0.4 kV
Feature: e nang le taolo ea mocheso
Romela Inquiry

 

 

three phase dry type transformer

E entsoe ka boqapi, e hahiloe ka nepo-Sefetoleli sa Mofuta oa Resin Cast Dry, se matlafatsang polokeho le tšebetso!

 

01 Kakaretso

1.1 Semelo sa Morero

Li-coil transformer tsa SCOTECH li entsoe ka bokhabane, li hahiloe, 'me li lekoa ho ikamahanya le maemo a holimo-limo a indasteri, ho kenyeletsoa NEMA, ANSI C.57, DOE, le IEEE, joalo ka ha ho sebetsa.

Li-transformer tsa mofuta o omileng oa SCOTECH li etselitsoe ts'ebeliso ea kahare le kantle, e hlokang tlhokomelo e nyane ka lebaka la kaho ea tsona e matla. Ka ho sebelisa lisebelisoa tse sireletsang tikoloho, li felisa tlhoko ea liphaephe tse sa cheng le ho tšoara likotlolo tseo hangata li hlokang li-transformer tse tlatsitsoeng ka metsi{1}. Bokhoni bona bo thusa ho kenya li-transformer tsa li-cast coil haufi le mojaro, ho matlafatsa botsitso ba sistimi le ho fokotsa tahlehelo e theko e boima ea mohala oa bobeli. Ho feta moo, fiberglass ea bona-moetso o matlafalitsoeng o fana ka matla a holimo-a potoloho le matla a motlakase. t e na le litšobotsi tse ntle tsa mochini, ha e na mapetso le lipudula tsa moea tse kahare, 'me e na le phallo e tlase ea lehae, e netefatsang ts'epo e phahameng le bophelo bo atolositsoeng ba ts'ebeletso.

 

 

1.2 Tlhaloso ea Setsebi

2500 kVA resin e entsoeng ka mokhoa o omileng oa sefetoleli le leqephe la data

E fetisetsoa ho
Georgia
Selemo
2024
Mofuta
Resin cast omileng mofuta oa transformer
Boitsebiso ba mantlha
Letlapa la tšepe la silicon le entsoeng ka lijo-thollo
Standard
IEC60076-11, EN50541-1, ISO9001, ISO14001
Rated Power
630kVA
Khafetsa
50 HZ
Mokhahlelo
Boraro
Sehlopha sa Vector
Dyn11
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
10 kV
Motlakase oa bobeli
0.4 kV
Lintho Tse Hlahang
Aluminium
Tšitiso
6%
Tlanya Changer
NLTC
Tlanya Range
± 2*2.5% @ motlakase oa mantlha
Ha ho Tahlehelo ea Mojaro
1.13KW
Ho Lahleheloa ke Moroalo
5.6KW
Boemo ba insulation
F

 

1.3 Litšoantšo

630 kVA resin e entsoeng ka setšoantšo sa setšoantšo se omileng sa transformer le boholo.

three phase dry type transformer diagram three phase dry type transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Transformer's magnetic core e entsoe ka tahlehelo ea boleng bo tlase-, lishiti tsa lijo-thollo- tse tšekaletseng, tse nang le likarolo tse 45{3}} tse fokotsang tahlehelo ea phallo. Ho matlafatsa ts'ebetso ea nako e telele, bokaholimo ba "magnetic core" bo ts'oaroa ka lesela le khethehileng le le sireletsang ho oxidation le corrosion, ha le ntse le fokotsa lerata la ts'ebetso. Motsoako ona oa lisebelisoa tse tsoetseng pele le moralo o mocha o netefatsa ts'ebetso e nepahetseng le bophelo bo bolelele lits'ebetsong tse fapaneng.

core and shell type transformer

 

2.2 Ho tsubella

cast coil

Li-winding tsa cast li hahiloe ka mekhahlelo e mengata, e 'ngoe le e' ngoe e na le mothinya o le mong, e leng ho matlafatsang khatello ea motlakase le ho fokotsa kotsi ea ho tsoa ka mokhoa o itseng. Ka tloaelo e entsoe ka tepi ea aluminium, moqapi ona o fokotsa haholo khatello ea mochine e bakoang ke ho fetoha ha mocheso ho transformer. Maqhubu a motlakase a tlase a sebelisa foil e sa khaotseng ea aluminium kapa koporo, e fanang ka matla a ho hanyetsa-khatello ea potoloho ka lebaka la khatello e tlase ea dielectric e amehang. Tlhophiso ena e ncha ea maqhubu ha e ntlafatse ho ts'epahala feela empa e boetse e netefatsa ts'ebetso e nepahetseng maemong a fapaneng a ts'ebetso.

 

2.3 Kopano ea ho Qetela

Kopano ea mantlha: Kenya setsi sa motlakase, ho netefatsa hore likarolo tsohle li hlophisitsoe ka mokhoa o sireletsehileng.

Ho Kena ha Maqhubu: Kenya li- windings tse phahameng le tse tlaase ho latela litlhaloso tsa moralo, ho boloka li-insulation tse ntle.

Insulation le Cooling System: Eketsa lisebelisoa tsa ho itšireletsa 'me u rale mokhoa oa ho pholisa o loketseng tikoloho.

Ho tšela Resin: Tšela resin ka mokhoa o ts'oanang ho pota-pota mapheo le mokokotlo, ho tlosa li-bubble tsa moea.

Mokhoa oa ho phekola: Phekola resin tlas'a maemo a loketseng ho theha lesela le tiileng la insulating.

Tlhahlobo ea ho Qetela ea Kopano: Etsa litlhahlobo tsa pono le liteko tsa motlakase ho etsa bonnete ba ho latela litekanyetso.

Kemiso ea Sebopeho sa Kantle: Kenya khetla e sa jeng-le litheminale, ho etsa bonnete ba hore lileibole li hlakile.

cast coil transformer

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Tekanyo ea ho hanyetsa matsoelintsoeke

/

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane

Khanyetso ea mela: e ka tlase ho kapa e lekana le 2%

HV (mohala)

LV (mohala)

Feta

 

0.28%

1.02%

2

Tekanyo ea karo-karolelano ea motlakase le ho hlahloba phallo ea karolo

/

Mamello ea karo-karolelano ea motlakase ho theipi ea mantlha: ± 1/10

Letšoao la khokahano: Dyn11

-0.07% ~ 0.12%

Dyn11

Feta

 

3

Tekanyo ea -nako e Khutšoane ea Impedance le Loss Loss

/

kW

kW

T:120 likhato

Z%: boleng bo lekantsoeng

Pk: boleng bo lekantsoeng

Pt: boleng bo lekantsoeng

6.01%

4.181

5.765

Feta

 

4

Tekanyo ea Ha ho-Tahlehelo ea Mojaro le Hona Joale ho 90% le 110% ea matla a matla a motlakase

/

kW

I0 : fana ka boleng bo lekantsoeng

P0: fana ka boleng bo lekantsoeng

90% Ur

0.261

0.9018

Feta

 

100% Ur

0.29

1.002

110% Ur

0.319

1.102

5

Teko ea Voltage e sebelisitsoeng

/

HV: 28kV 60s

LV: 3kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

 

6

Teko ea ho mamella Voltage e kentsoeng

/

Matla a sebelisoang (kV):2 Ur

Matla a susumetsoang (kV): 0.8

Nako:40

Hangata (HZ): 150

Ha ho ho putlama ha motlakase oa liteko

Feta

 

7

Teko ea Phallo e sa Feleng

pC

Boemo bo phahameng ba ho tsoa ha karolo e itseng e tla ba 10 pC

<10

Feta

 

 

three phase dry type transformer test
3 phase dry type transformer test

 

 

04 Ho paka le ho Romela

3 phase dry type transformer package
3 phase dry type transformer shipping
 

 

05 Sebaka le Kakaretso

Ka kakaretso, li-transformer tsa mofuta o omileng oa resin, tse nang le likarolo tsa tsona tse ntle tsa polokeho, phetolo e sebetsang ea matla, litšobotsi tse ikhethang tsa tikoloho, le tlhokomelo e bonolo, li fetohile lisebelisoa tsa motlakase tse ratoang haholo libakeng tsa khoebo le tsa indasteri. Ebang ke litsing tsa motlakase tsa litoropong, lirapeng tsa boikhathollo tsa indasteri,{1}}meaho e melelele, kapa lits'ebetso tsa metro, li-transformer tsa mofuta oa resin cast li fana ka ts'ehetso e tšepahalang le e tsitsitseng ea motlakase. Ho khetha{3}li-transformer tsa boleng bo holimo tsa mofuta oa resin cast dry ha se tiisetso feela ea katleho ea tlhahiso ea likhoebo empa hape ke tlatsetso e ntle ntlafatsong e tala le e tsitsitseng. Re ikemiselitse ho u fa lihlahisoa tsa boleng bo holimo le lits'ebeletso tsa profeshenale, 'me re labalabela ho sebelisana le uena ho tsamaisa tsoelopele ea indasteri.

three phase dry type transformer enclosure

 

Hot Tags: mefuta e meraro ea mofuta o omileng oa transformer, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry