6 MVA Motlakase Transformers-33/2.2 kV|Afrika Boroa 2025
Matla: 6MVA
Matla: 33/2.2kV
Tšobotsi: Ho chesa{0}}dip galvanized radiator

Li-transformer tse sebetsang hantle le tse tšepahalang tsa 6 MVA- tse qoelisoang bakeng sa li-inverter system, tse fanang ka motlakase o bolokehileng, tahlehelo e tlase, le ts'ebetso e tšoarellang libakeng tse kantle tsa Afrika Boroa.
01 Kakaretso
1.1 Tlhaloso ea Morero
Oli ena ea 6MVA{1}}e qoelitsoemotlakase oa motlakasee ile ea isoa Afrika Boroa ka 2024 bakeng sa ho sebelisoa ho li-inverter systems. Transformer ea motlakase ea 6 MVA e na le matla a lekantsoeng a 6000 kVA, motlakase o ka sehloohong oa 33 kV, le motlakase oa bobeli oa 2.2 kV. E latela ka tieo litekanyetso tsa IEC 60076
Leha li-inverters li ka fetola matla a DC hore e be matla a AC, motlakase oa grid hangata o phahame ho feta kamoo inverter e ka mamellang kateng. Ho netefatsa ts'ebetso e bolokehileng ea sistimi, transformer ea rona e theola motlakase o phahameng oa grid (33 kV) ho ea ho 2.2 kV e amohelehang ho inverter. Transformer e boetse e fana ka karohano ea motlakase, khatello ea harmonic, le ts'ireletso ea sistimi, ho netefatsa ts'ebetso e bolokehileng le e tsitsitseng lipakeng tsa inverter le grid.
E ithorisa ka ts'ebetso e phahameng ea ts'ebetso. Ha ho-tahlehelo ea mojaro e tlase joalo ka 6.2 kW, 'me tahlehelo ea thepa e tlase joalo ka 39 kW, e leng ho fokotsa tšebeliso ea matla le litšenyehelo tsa ts'ebetso. 7% impedance e netefatsa hore motlakase o tsitsitse ka nako e khutšoane-ea potoloho, 'me maqhubu a koporo a fana ka conductivity e ntle haholo, e sireletsang motlakase le marang-rang.
Li-transformer tsa motlakase tsa 6 MVA li tlatsitsoe ka oli ea PCB{{1}e sa lefelloeng ea liminerale, e matlafatsang polokeho ea tikoloho. Seseteme ea ho pholisa e sebelisa moea o pholileng oa tlhaho 'me e na le radiator e chesang e chesang-dip galvanized. Sena se netefatsa phediso e hlwahlwa ya mocheso le ho hanyetsa maemo a lehodimo a matla, ho etsa hore e be tse loketseng tikoloho ya kantle ya Afrika Borwa.
Lisebelisoa tse tloaelehileng li kenyelletsa tekanyo ea tekanyo ea oli, valve ea khatello ea khatello, lisebelisoa tsa ho shebella mocheso oa oli le matsoelintsoeke, relay ea Buchholz, le mochine o phefumolohang, ho netefatsa ts'ebetso e sireletsehileng le e tsitsitseng le ho lelefatsa bophelo ba tšebeletso ea thepa. Ka bokhabane ba eona bo phahameng, tahlehelo e tlase, le moralo o matla, 6MVA ena ea oli-e qoelisoang ka matla a ho fetola motlakase ha se khetho e nepahetseng feela bakeng sa gridi e hokahantsoeng{{3}e hokahaneng, empa hape ke karolo ea mantlha e tšepahalang bakeng sa merero e mecha ea matla a matla.
1.2 Tlhaloso ea Setsebi
Tlhaloso ea li-transformer tsa motlakase tsa 6MVA le leqephe la data
|
E fetisetsoa ho
Afrika Boroa
|
|
Selemo
2024
|
|
Mofuta
Oli e Kentsoeng ka Matla Transformer
|
|
Standard
IEC 60076
|
|
Rated Power
6MVA
|
|
Khafetsa
50HZ
|
|
Mokhahlelo
Boraro
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
33KV
|
|
Motlakase oa bobeli
2.2 KV
|
|
Lintho Tse Hlahang
Koporo
|
|
Lintho Tse Pholisang
Oli ea liminerale e sa lefelloeng ea PCB
|
|
Sehlopha sa Vector
Dyn11
|
|
Tšitiso
7 %
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*3% @ Lehlakore la mathomo
|
|
Ha ho Tahlehelo ea Mojaro
6.2KW
|
|
Ho Lahleheloa ke Moroalo
39KW
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
6MVA ea li-transformer tsa matla a motlakase li taka le lebitso la lebitso
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa
Re latela ka tieo lits'oants'o tsa meralo, litekanyetso, le mekhoa ea tlhahiso bakeng sa mohato o mong le o mong, ho netefatsa kopano e nepahetseng ea mantlha, khokahano e sireletsehileng ea likarolo tse phelang, le motheo o tšepahalang. Ka taolo ena e thata, li- iron cores tsa rona li fumana tahlehelo e fokolang, lerata le fokotsehileng, matla a ho koala a mangata, le ho sebetsa ka thata ha nako e telele-ea potoloho, ho netefatsa hore{2}}transformer e sebetsa nako e telele.

2.2 Ho tsubella

Ho tsamaisa li-coil ke ts'ebetso ea bohlokoa. Re sebelisa{1}koporo ea boleng bo holimo, e netefatsang tšebetso e ntle haholo le matla a mochini. Nakong ea matsoeli, re boloka mohatsela o tšoanang, sebaka se tsitsitseng, le likarolo tse thata, tse makhethe ho thibela libaka tse chesang haholo le ho se sebetse ha mocheso. Ka mor'a ho tsoelipana, li-coil lia bōptjoa, li sirelelitsoe, 'me li kenngoe, ka tlhahlobo e tiileng ea boleng, ho netefatsa botsitso tlas'a khatello e khutšoanyane-ea potoloho, ea mocheso le motlakase ha e kopana le litlhoko tsa khokahanyo ea Dyn11.
2.3 Tanka
Poleite-radiator ea mofuta oa ho chesa-ina ka masenke 'me e pentiloe ka botala ba avocado ea C12. Nakong ea tlhahiso ea tanka ea oli ea transformer le radiator, li-welds tsohle li etsoa ka hloko ho netefatsa hore ha ho na ho lutla, ho netefalitsoeng ke tlhahlobo ea khatello ea moea ho 30 kPa bakeng sa lihora tse 8. Bokahare le bokantle ba bokaholimo bo hloekisitsoe ho thibela kutu, bo netefatsang ho tšoarella ha nako e telele{7}} le mokhoa o tšepahalang oa ho felisa mocheso.


2.4 Kopano ea ho Qetela

Ka mor'a hore motsoako oa transformer le windings li bokelloe, sesebelisoa se kenngoa ka kamoreng ea ho omisa. Hang ha e omisitsoe, ea phahamisoa ebe e kenngoa ka tanka ea oli. Transformer ena e na le sete e felletseng ea lisebelisoa, ho kenyeletsoa le poleiti-radiator ea mofuta, sesupa sa boemo ba oli, valve e fokotsang khatello, sesupa sa mocheso oa oli, relay ea Buchholz, sekontiri sa oli, phefumoloho,-ho fetola mocheso, le sesupo sa mocheso o tsoelipanang. Lisebelisoa tsohle li kentsoe ho latela litlhoko tsa rona tse tiileng tsa tlhahiso, ka lithapo tse makhethe le tse hlophisitsoeng. Ka mor'a ho kenya lisebelisoa, ts'ebetso ea kopano e phethoa ka ho tlatsa oli le ho tiisoa, likhokahano tsa motlakase le liteko, le tlhahlobo ea ponahalo le matšoao.
03 Ho etsa liteko
Teko Tekanyetso
IEC 60076-1-2011, Li-transformer tsa matla - Karolo ea 1: Kakaretso
IEC 60076-3-2013, Power Transformers-Karolo ea 3: Maemo a insulation, liteko tsa dielectric le ho tlosoa ha kantle moeeng
IEC 60076-7-2018, Power transformers- Karolo ea 7 Tataiso ea ho laela bakeng sa li-transformer tsa matla tse qoelisoang ka oli ea liminerale


Teko e Tloaelehileng
1. Tekanyo ea likhase tse qhibilihisitsoeng ka har'a mokelikeli oa dielectric ho tsoa phaposing e 'ngoe le e 'ngoe e arohaneng ea oli ntle le phaposi ea diverter switch.
2. Tekanyo ea Ratio ea Voltage le Check of Phase Displacement
3. Tekanyo ea Maqhubu a Khanyetsano
4. Tekanyo ea khanyetso ea DC Insulation Pakeng Tsa Moea o Mong le o Mong ho ea Lefatšeng le Pakeng tsa Maqhubu
5. Teko ea Voltage e sebelisitsoeng
6. Tekanyo ea Che-Tahlehelo ea Mojaro le Hona Joale
7. Teko ea Voltage e entsoeng
8. Tekanyo ea-mokhoa o mokhuts'oane oa ho se be teng ha potoloho le tahlehelo ea mojaro
9. Tlhahlobo ea Leak e nang le Pressure For Liquid-Immersed Transformers
Kamora Teko e Tloaelehileng ea sehlahisoa sena e latela litlhoko tsa IEC 60076-1-2011, IEC 60076-3-2013, IEC 60076-7-2018 standard mme sehlahisoa sea tšoaneleha. Qetello: Ea tšoanelehang, tumello ea ho tsoa fekthering.
04 Ho paka le ho Romela
4.1 Ho paka



1. Ka mor'a tlhahlobo ea fektheri, tlosa oli (kapa u siee e nyenyane), omisa ka hare, tlatsa moea o omileng kapa naetrojene, 'me u boloke khatello e nyenyane e ntle.
2. Kenya mochine oa ho lekanya khatello le valve ea liphallelo ho thibela khatello e feteletseng.
3. Tlosa lisebelisoa (li-radiator, sekontiri sa oli, relay ea khase, lipeipi) 'me u li phuthe ka thoko.
4. Tiisa li-flange tsohle ka li-gaskets tsa bobeli 'me u tiise liboutu.
5. Eketsa ba sireletsang sekhutlo 'me u phuthe yuniti ka filimi e sireletsang.
6. Paka lisebelisoa tse arohaneng ka tšepe ea angle le plywood; boloka mmele o moholo o hlobotse.
7. Beha transformer ka har'a tšepe-ea foreimi ea lepolanka; hokela lisebelisoa tsa ho ts'oha ha ho hlokahala.
8. Tšoaea kereiti ka forklift le bohareng-ea{2}}matšoao a khoheli.
9. Koahela kreiti ka tarp e thibelang mongobo-.
4.2 Ho tsamaisa thepa

Pele o kenya, lekanya boholo le boima ba transformer, 'me u rale tsela e qobang bophahamo, bophara le boima ba lithibelo. Sebelisa-libethe tse tlase kapa literaka tse khethehileng tse nang le bokhoni bo lekaneng.
Lokahanya setsi sa khoheli sa transformer le koloi. Sebelisa litšepe tsa kanale le mekhoa e nepahetseng ea ho tiisa ho tiisa motheo oa teraka, ha ho lumelleha. Sireletsa transformer ka likhoele kapa liketane ka likoti tse khethiloeng tsa lipalangoang, ho qoba likarolo tse senyehang joalo ka li-radiator le lihlahla. Notlela likarolo tse ka hare 'me u tiise menyako eohle.
Boloka lebelo Le ka Tlase kapa le lekana le 60 km/h mme o sekaseke Ka tlase ho kapa ho lekana le likhato tse 15 nakong ea lipalangoang. Qoba ho sisinyeha ka tšohanyetso le ho thothomela ho matla. Abela batho ba felehelitseng ho hlahloba hore na ba tlama hakae le ho emisa lipalangoang maemong a leholimo a mabe.
Ha u phahamisa, boloka li-angles tsa thapo Li le Ka tlase ho kapa li lekana le likhato tse 60. Sebelisa li-spreader bar ha ho hlokahala. Ka linako tsohle phahamisa u otlolohile, 'me bakeng sa li-unit tse se nang li-lugs tse holimo, sebelisa lithupa tse phahamisang tlase.
05 Sebaka le Kakaretso
Ka tlhahiso e nepahetseng,{0}}lisebelisoa tsa boleng bo holimo, le maemo a thata a ho kopanya, 6MVA enaoli-sefetoleli sa motlakase se qoelitsoenge fana ka ts'ebetso e tšepahalang, e sebetsang hantle, le{0}}ea nako e telele. Lintlha tsohle, ho tloha ho li-cores le lifens ho ea ho tanka le lisebelisoa, li etselitsoe ho netefatsa ts'ebetso e bolokehileng le e tsitsitseng ho marang-rang a inverter-litsamaiso tse hokahaneng ho pholletsa le Afrika Boroa.

Hot Tags: li-transformer tsa motlakase, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
15 MVA Step Up Power Transformer-4.16/69 kV|Guyana 2023
3000 kVA Custom Power Transformers-33/11 kV|Afrika B...
10 MVA Main Power Transformer-33/33 kV|Afrika Boroa ...
8 MVA Small Power Transformer-33/33 kV|Zimbabwe 2024
6 MVA Three Phase Power Transformer-33/6.6 kV|Afrika...
3150 kVA Transformer In Power System-0.4 / 6.6 kV|Af...