6 MVA Three Phase Power Transformer-33/6.6 kV|Afrika Boroa 2024

6 MVA Three Phase Power Transformer-33/6.6 kV|Afrika Boroa 2024

Naha: Afrika Boroa 2024
Bokhoni: 6 MVA
Matla: 33/6.6 kV
Feature: Ho chesa masenke
Romela Inquiry

 

 

three phase power transformer

Boqapi bo tsamaisa bokhabane - re sireletsa watt e 'ngoe le e 'ngoe ea matla ka theknoloji!

 

01 Kakaretso

1.1 Semelo sa Morero

6 MVA Oil-transformer e qoelisoang ea phepelo ea motlakase e ile ea isoa Afrika Boroa ka 2024. Matla a lekantsoeng a transfofoma e Immersed oli ke 6000 kVA e nang le ONAN cooling, motlakase oa mantlha ke 33 kV le ±2*3% tapping range (NLTC), motlakase oa bobeli ke 6.6 kV ea sehlopha sa Dyn1.

Li-transformer tsa 6MVA li sebelisoa haholo indastering, merafong, lifemeng tsa motlakase le-liteishene tse kholo tsa ho pompa, 'me li ka fana ka matla a tsitsitseng bakeng sa lienjene tse kholo, metjhini ea ho etsa ente, metjhini ea litšepe le lisebelisoa tse ling{2}} tse phahameng. Ho phaella moo, ts'ebetso ea eona e sebetsang hantle le e ka tšeptjoang le ho feto-fetoha ha mojaro o matla ho etsa hore e be le karolo ea bohlokoa tsamaisong ea phetisetso ea matla le kabo ea matla.

 

 

1.2 Tlhaloso ea Setsebi

6 Litlhaloso tsa motlakase oa MVA le leqephe la data

E fetisetsoa ho
Afrika Boroa
Selemo
2024
Mofuta
Oli e Kentsoeng ka Matla Transformer
Standard
IEC 60076
Rated Power
6MVA
Khafetsa
50 HZ
Mokhahlelo
Boraro
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
33kV
Motlakase oa bobeli
6.6kV
Lintho Tse Hlahang
Koporo
Sehlopha sa Vector
YNa0
Tšitiso
0.98%
Tlanya Changer
NLTC
Tlanya Range
±2*3%
Ha ho Tahlehelo ea Mojaro
6.2KW
Ho Lahleheloa ke Moroalo
39KW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

6 MVA sets'oants'o sa sefetoleli sa matla le boholo.

20251016140248384177

20251016140249385177

20251016140249386177

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Motsoako o felletseng oa ts'ekamelo o amoheloa ho ntlafatsa tataiso ea phallo, ho felisa ts'ebetso ea sebaka sa "flux saturation" lenonyeletsong la mokokotlo oa tšepe, ho fokotsa -tahlehelo ea mojaro le{1}}moroalo oa hona joale oa mokokotlo oa tšepe, le ho fokotsa lerata la transformer. E le ho matlafatsa bokhoni ba ho hanela potoloho e khutšoanyane, lipekere tse ngata tsa khatello li ajoa ho pota-potile letlapa la khatello, 'me likarolo tse ka holimo le tse tlaase tsa khatello e phahameng le tse tlaase li kopantsoe ke maballo a tšehetso, e le hore mokokotlo oa tšepe o fetohe kaofela. Ntle le moo, bokaholimo ba karolo ea mantlha bo koahetsoe ka pampiri ea tšepe ea silicon sekhomaretsi se ikhethileng, e le hore lakane ea tšepe ea silicon le lakane li kopane, 'me motheo oa tšepe e be 'mele o le mong ka mor'a ho folisa. Litšehetso tsa lehong la laminated tsa matla a phahameng li sebelisoa pakeng tsa karolo e ka tlaase ea 'mele le lerako la tanka, ho etsa hore karolo e ka tlaase ea' mele e bolokehe le boemo bo ka tšeptjoang.

3 phase transformer core

 

2.2 Ho tsubella

continuous winding

Ka ho tsoelipana ho tsoelang pele, lithapo li hlophisoa ka thata le ka ho lekana, e le hore kabo ea tšimo ea motlakase e be e leka-lekaneng. Moralo ona ha o fokotse feela libaka tse chesang tsa lehae tse ka hlahisoang ka matsoelintsoeke, empa hape o fokotsa tšitiso ea motlakase ka katleho, ka tsela eo e ntlafatsa katleho le botsitso ba transformer. Haholo-holo lits'ebetsong tse phahameng tsa maqhubu kapa matla a phahameng, moea o tsoelang pele o ka fokotsa tahlehelo haholo mme oa ntlafatsa lebelo la karabelo le kutloisiso ea transformer.

 

2.3 Tanka

E etselitsoe litekanyetso tsa 6MVA, tanka ena ea transformer e fana ka ts'ehetso ea mochini bakeng sa mantlha, e na le oli e sireletsang, 'me e thusa ho ntša mocheso o sebetsang ka mabota a eona a nang le masenke kapa mapheo. E netefatsa tšireletso e feletseng ea likarolo tsa ka hare ho tloha tikolohong.

step down power transformer

 

2.4 Kopano ea ho Qetela

transformer 3 phase

Kopano ea Core le Maqhubu: Ho kenya li-winding ka nepo mokokotlong le ho etsa liphekolo tse hlokahalang tsa ho koala joalo ka ha ho hlokoa.

Kopano ea Karolo e sebetsang: Ho kenya li-cores tse kopaneng le li-winding ka tanka ea oli, ho netefatsa ho nepahala ha litlhoko tsa ho kenya le ho kenya letsoho.

Kalafo ea Oli: Ho kenya oli e sireletsang ka tanka bakeng sa ho kenya letsoho le ho pholisa likarolo tse sebetsang, ha u ntse u hlahloba boleng ba oli le boemo.

Kenyelletso ea Sehokelo: Ho kenya lisebelisoa tse futhumatsang, li-relay tse sireletsang, lisebelisoa le li-valve ho netefatsa ts'ebetso e bolokehileng le ts'ebetso ea transformer.

 

 

03 Teko

1. Tekanyo ea likhase tse qhibilihisitsoeng ka har'a mokelikeli oa dielectric ho tsoa phaposing e 'ngoe le e 'ngoe e arohaneng ea oli ntle le phaposi ea diverter switch.

2. Tekanyo ea Karolelano ea Voltage le Check of Phase Displacement

3. Tekanyo ea Maqhubu a Khanyetsano

4. Tekanyo ea khanyetso ea DC Insulation Pakeng Tsa Moea o Mong le o Mong ho ea Lefatšeng le Pakeng tsa Maqhubu

5. Teko ea Voltage e sebelisitsoeng

6. Tekanyo ea Che-Tahlehelo ea Mojaro le Hona Joale

7. Teko ea Voltage e entsoeng

8. Tekanyo ea-mokhoa o mokhuts'oane oa ho se be teng ha potoloho le tahlehelo ea mojaro

9. Teko ea ho Dutla ka Khatello Bakeng sa Mokelikeli-Li-Immersed Transformers

iec 60076

 

04 Ho paka le ho Romela

led power supply transformer
 
power transformer company
 
 

05 Sebaka le Kakaretso

Qetellong, li-transformer-tse qoelisoang ka metsing, ka ts'ebetso ea tsona e pholileng ea maemo a holimo le moralo o matla, ke khetho e nepahetseng bakeng sa litsamaiso tse fapaneng tsa motlakase. Ha li fane feela ka ts'ebetso e ntle ea motlakase empa hape li boloka ts'ebetso le botsitso nakong ea ts'ebetso ea nako e telele. Ebang ke marang-rang a kabo ea litoropo kapa lirapeng tsa boikhathollo tsa indasteri, li-transformer tsena li ka fihlela litlhoko tsa hau tsa motlakase le ho netefatsa phepelo e tšepahalang ea matla. Re ikemiselitse ho u fa litharollo tse loketseng ka theknoloji e tsoetseng pele le{4}}tšebeletso ea boleng bo holimo. Re leboha tlhokomelo ya hao le tshepo ya hao ho-lisebediswa tsa rona tsa ho tsamaisa oli tse qoeletseng; re labalabela ho sebelisana le uena ho theha bokamoso bo khanyang.

cooper power transformers

 

Hot Tags: motlakase oa mekhahlelo e meraro, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry