15 MVA Step Up Power Transformer-4.16/69 kV|Guyana 2023

15 MVA Step Up Power Transformer-4.16/69 kV|Guyana 2023

Naha: Guyana 2023
Matla: 15MVA
Matla: 4.16/69kV
Sebopeho: ka OLTC
Romela Inquiry

 

 

step up power transformer

Matla a tsitsitseng, a matlafatsa bokamoso{{0}ho khetha li-transformer tsa rona ho bonesa watt e 'ngoe le e 'ngoe ea matla!

 

01 Kakaretso

1.1 Semelo sa Morero

Sefetoleli sena sa 15 MVA se qoelisoa ka oli se entsoe ke rona ka 2023, matla a lekantsoeng a transformer ke 15 MVA, motlakase oa mantlha ke 4.16 kV ka +4 × 1.667% ho -12×1.667% tapping range(OLTC), motlakase o tlase ke 69 kV. Re hlahisitse phetoho ena ea OLTC ea ho phahamisa matla ka sebopeho sa thepa e nkile letoto la liphetoho tse kholo, ka boima bo bobebe, boholo bo nyane, ho tsoa ka mokhoa o fokolang, tahlehelo e tlase, lerata le tlase, ts'epahalo e phahameng, ts'ireletso e khuts'oane ea potoloho e khuts'oane, e ka fokotsa palo e kholo ea tahlehelo ea grid ea matla, litšenyehelo tsa ts'ebetso le melemo ea moruo. Mokhoa oa khokahano oa YNd11 o fana ka tšebelisano e ntle ea grid, ha o ntse o hatella li-harmonics tsa boraro le ho ntlafatsa boleng ba ts'ebetso ea grid. Lehlakore le phahameng la motlakase (Y) ke khokahano ea linaleli e nang le ntlha e sa nke lehlakore e ka theoang ka ho toba kapa ka ho hanyetsa fatše ho fana ka tlhahiso e tsitsitseng ea matla a phahameng.

 

1.2 Tlhaloso ea Setsebi

Tlhaloso ea 100 MVA ea motlakase oa motlakase le leqephe la data

E fetisetsoa ho
Guyana
Selemo
2023
Mohlala
SZ-15 MVA-69kV
Mofuta
Oli e Kentsoeng ka Matla Transformer
Standard
IEEE C57.12.00
Rated Power
15MVA
Khafetsa
60HZ
Mokhahlelo
Boraro
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
69kV
Motlakase oa bobeli
4.16kV
Lintho Tse Hlahang
Koporo
Sehlopha sa Vector
YNd11
Tšitiso
9.10%
Tlanya Changer
OLTC
Tlanya Range
+4*1.667%~-12*1.667%@HV lehlakore
Ha ho Tahlehelo ea Mojaro
10.234KW(20 likhato)
Ho Lahleheloa ke Moroalo
64.220KW(85 likhato)
Lisebelisoa
Tlhophiso e Tloaelehileng
Litlhaloso
N/A

 

1.3 Litšoantšo

15 MVA sets'oants'o sa setšoantšo sa motlakase oa motlakase le boholo.

step up power transformer diagram step up power transformer nameplate

 

step up power transformer wiring diagram 15mva power transformer drawing

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Khampani ea rona e sebelisa{0}}volt e phahameng-ea batang{2}}leshiti la silicon le thethehileng, le se nang-tlamang lesoba, sebopeho sa foreimi, d-mohaho oa joko oa sebopeho sa khola ho e-na le- sethala se seholo, manonyeletso. Koko e na le burr e nyane le coefficient e tlase ea lamination. Ha ho-tahlehelo ea mojaro, ho se be-moroalo hona joale le boemo ba lerata li fokotsehile ka ho sebetsa{10}}manonyeletso a mangata a iron core.

core of the transformer

 

2.2 Ho tsubella

Continuous winding design

1. Moqapi o tsoelang pele oa ho phunya: Ho sebelisoa mofuta o mong o tsoelang pele oa tangle le poleiti e ka hare e le 'ngoe e tsoelang pele ea mofuta o sebelisoang, e thusang ho ntlafatsa kabo ea longitudinal capacitance ea coil tlas'a motlakase oa tšusumetso. Moqapi ona o ka fokotsa khatello ea masimo a motlakase, e le hore coil e be le ts'ebetso e ntle ea motlakase ka khatello e phahameng.

2. Sebopeho sa phepelo ea oli e tataisoang: sebopeho sa phepelo ea oli se tataisoang se sebelisoa ho thusa ho fokotsa ho phahama ha mocheso oa moea. Moqapi ona o boloka mocheso ka hare ho coil mme o thusa ho ntlafatsa polokeho le botsitso ba transformer.

 

2.3 Tanka

1. Ts'ebetso ea ho tiisa: Tanka ea oli e tiisitsoe ka moeli oa ho emisa ho etsa bonnete ba hore oli e sireletsang ea transformer e ka koaloa ka katleho ka har'a tanka ea oli ho qoba ho lutla le oxidation ea oli e sireletsang.

2. Thibela kutu-: Tanka ea oli e entsoe ka lintho tse thibelang ho bola{2}}'me pente e hlokahalang bakeng sa lisebelisoa tsa ka tlung e sebelisetsoa ho matlafatsa ho thibela ho bola ha tanka ea oli le ho lelefatsa bophelo ba ts'ebeletso.

3. Teko ea ho sibolla ha ho lutla: ho chesehela le ho tiisa tanka ho bile le liteko tse tharo tsa ho lemoha ho lutla (fluorescence, khatello e ntle, tlhahlobo e mpe ea ho lutla ha khatello) ho netefatsa ho tiea le polokeho.

oil tank

 

2.4 Kopano ea ho Qetela

oil conservator

Kopano ea ho qetela ea-ea motlakase e qoelisoang ka oli e hlahisoang ke khamphani ea transfoma hangata e kenyelletsa mehato e mengata ea bohlokoa:

1. Kopano ea mantlha: Kopano ea mantlha hangata ke mohato oa pele oa ts'ebetso ea ho qetela ea kopano. Sena se kopanyelletsa ho bokellana le ho tiisa core ea transformer, e nang le-matlapa a phahameng a tšepe a motlakase. Koko e tlameha ho bokelloa ho latela litlhaloso tse nepahetseng ho netefatsa thepa e nepahetseng ea makenete le tahlehelo e nyane ea mantlha.

2. Ho Kenya Li-Windings: Ts'ebetso ena e kenyelletsa ho kenya maqhubu a phahameng-voltage (HV) le a tlase-voltage (LV) holim'a core. Li-winding hangata ke li-conductors tsa koporo tse sirelelitsoeng ka hloko, tse behiloeng ka hloko, 'me li kopantsoe ho latela moralo oa transformer.

3. Ho Kenya Tanka le Radiator: Tanka ea transformer, hammoho le li-radiator leha e le life tse amanang le tsona kapa mapheo a pholileng, li kentsoe mothating ona. Tanka e fana ka bolulo bakeng sa li-core le windings 'me e ka koaloa hore e be le oli e sireletsang.

4. Insulation, Connections, and Accessories: Mehaho e sireletsang, e kang lihlahla, li-load, li-changer tsa lipompo, le lisebelisoa tse ling li kenngoa 'me li hokahanngoa le mapheo. Li-insulation le litšehetso tse ling li eketsoa ho netefatsa ts'ebetso e bolokehileng le e tšepahalang.

5. Ho Tlatsoa ha Oli le Ho Tiisa: Transformer e tletse oli ea insulating ka mokhoa o laoloang ka hloko. Hang ha e tlatsitsoe, transformer e tiisitsoe ho thibela ho kena ha mongobo le ho boloka botšepehi ba oli.

 

 

03 Teko

Teko ea ho hanyetsa insulation: e sebelisetsoang ho bona boleng ba lisebelisoa tsa ho kenya letsoho ho thibela ho senyeha ha insulation. Hoa hlokahala ho etsa bonnete ba hore transformer ha e sebetse 'me e sebelisa lisebelisoa tse nepahetseng tsa tlhahlobo ea khanyetso.

Teko e ntle ea voltage: Ho sebelisoa motlakase o phahameng ho transformer nakong ea tlhahlobo ho leka ts'ebetso ea eona ea ho kenella ka motlakase o lekantsoeng. Sena se hloka boikamahanyo bo tiileng mekhoeng e bolokehileng ea ts'ebetso le litiisetso tsa hore lisebelisoa tsa tlhahlobo li fihlella maemo.

Teko e mpe ea khatello: Ntho ena ea teko e hlahloba ts'ebetso ea ho kenya letsoho ea transformer ka matla a tlase. Hape hoa hlokahala ho nka mehato e nepahetseng ea tšireletso ho netefatsa hore tlhahlobo e etsoa ka mokhoa o sireletsehileng.

Teko ea Ac resistance: Lekola khanyetso ea motheo ea matsoelintsoeke ho netefatsa ho ts'epahala ha sistimi ea ho theola fatše.

Ho lahleheloa ke matla le ho-liteko tsa hona joale: Liteko tsena li sebelisetsoa ho lekanya ho se be{1}}sebelisoa ha motlakase le ho sebetsa ha transfoma.

Tlhahlobo ea mojaro: Ka ho sebelisa mojaro o lekantsoeng, litekanyetso tsa ts'ebetso ea transformer tlas'a maemo a boima a lekantsoeng a lekantsoe.

 

transformer type test

 

 

04 Ho paka le ho Romela

4.1 Ho paka

Ho paka le ho tsamaisoa ha oli-e qoelisoang ka motlakase oa motlakase o hlahisoang ke k'hamphani ea transfoma ho kenyelletsa mehato e mengata ea bohlokoa ho netefatsa hore thepa e fihla e bolokehile ebile e sireletsehile. Ka tlase ke tlhaloso e akaretsang ea ts'ebetso:

1. Ho paka: Hang ha transformer e fetile kopano ea ho qetela, ho kenyelletsa le ho hlahloba le ho hlahloba boleng, e lokiselitsoe ho paka. Likarolo tsa li-transformer, ho kenyeletsoa tanka, mantlha, li-winding le lisebelisoa tse amanang le tsona, li sirelelitsoe ka hloko ebile li sirelelitsoe bakeng sa lipalangoang. Lisebelisoa tsa ho paka, tse kang likreiti tsa lepolanka, li-foam padding, le likhoele, li khethoa ho fana ka cushion le tšireletso e lekaneng.

2. Tšireletso le Tšireletso ea Corrosion: Likarolo tsa transformer li tšoaroa ka lisebelisoa tse nepahetseng tsa ho sireletsa ho sireletsa khahlanong le kutu nakong ea lipalangoang le polokelo.

power transformer specification

 

4.2 Ho tsamaisa thepa

15mva power transformer manufacturer

Ho sireletsa bakeng sa Lipalangoang: Likarolo tsa transformer li sirelelitsoe ka har'a sephutheloana ho thibela motsamao le ho netefatsa botsitso nakong ea lipalangoang. Tokisetso e sireletsehileng le e leka-lekaneng e bolokiloe ho thibela khatello e sa hlokahaleng karolong efe kapa efe ea transformer.

Boitsebiso le Litokomane: Karolo e 'ngoe le e' ngoe e pakiloeng e ngotsoe, 'me litokomane tse qaqileng lia lokisoa, ho kenyelletsa le manane a ho paka, litaelo tsa thomello, le litumello leha e le life tse hlokahalang kapa litifikeiti tsa lipalangoang.

Ho Laola le Lipalangoang: Likarolo tse pakiloeng li laeloa likoloing tse loketseng tsa lipalangoang, joalo ka litereilara tse nang le flatbed kapa li-container tsa likepe, li sebelisa li-crane kapa lisebelisoa tse ling tsa ho tšoara. Ho ka hlokahala lipalangoang tse khethehileng bakeng sa li-transformer tse kholo kapa tse boima.

Ho tšoara le ho laolla: Nakong ea lipalangoang, likarolo tsa transformer li tšoaroa ka hloko ho thibela tšenyo. Ha u fihla sebakeng seo u eang ho sona, ho hlokomeloa nakong ea ho laolla ho netefatsa ho tšoaroa ka mokhoa o bolokehileng le o nepahetseng

 

 

05 Sebaka le Kakaretso

Boitokisetso: Etsa bonnete ba hore motheo o bataletse ebile o tsitsitse, 'me lisebelisoa tsohle li lokile.

Lipalangoang le Ho Hoimisa: Tsamaisa transformer ho ea setšeng, e phahamisetse sebakeng, 'me u e sireletse.

Kenyelletso ea Sehlomathiso: Kenya lisebelisoa tse joalo ka lisebelisoa tse futhumatsang, seboloki sa oli, le lihlahla.

Khokelo ea Motlakase: Qetella likhokahano tsa likhoele tsa motlakase o phahameng le o tlase kapa li-busbar, 'me u netefatse hore ho theoa ho nepahetseng.

Ho Tlatsa Oli le Tlhahlobo: Tlatsa transformer ka oli e sireletsang 'me u hlahlobe maemo a oli le boleng.

Teko le Komisi: Etsa liteko tsa motlakase tse joalo ka ho kenya letsoho, ho hanyetsa, le liteko tsa karolelano.

Ts'ebetso ea Teko: Etsa ts'ebetso ea liteko tlas'a mojaro 'me u netefatse litekanyo tsohle pele ho ts'ebetso ea ho qetela.

power transformer
electrical transformer

 

Hot Tags: phahamisa motlakase oa motlakase, moetsi, mofani oa thepa, theko, litšenyehelo

E fetileng:Ha ho Boitsebiso

Romela Inquiry