300 kVA Pad-mounter-34.5/0.208 kV|USA 2024
Matla: 300kVA
Matla: 34.5GrdY/0.208kV
Feature: loop feed

Tiisetso ea motlakase e tsitsitseng le ts'ebetso e ntlafetseng - ea-phase ea mekhahlelo e meraro-e behoang ka transformer e etsa hore phepelo ea motlakase e be bohlale ho feta!
01 Kakaretso
1.1 Semelo sa Morero
300 kVA phase three phase mounted transformer e ile ea isoa Chaena ka 2024. Matla a lekantsoeng a transformer ke 300 kVA e nang le pholiso ea ONAN. Motlakase oa mantlha ke 34.5GrdY/19.92 kV e nang le ± 2 * 2.5% tapping range (NLTC), motlakase oa bobeli ke 0.12 / 0.208 kV, ba thehile sehlopha sa vector sa YNyn0.
Li-transformer tse kentsoeng ka mekhahlelo e meraro li sebelisoa hangata ho tsamaiseng matla a litoropo le lits'ebetsong tsa indasteri. Tšebeliso ea Load Break Connectors e lumella hore ho be le khokahanyo e sireletsehileng le ho khaoloa ha matla ha u ntse u le tlas'a mojaro, ho matlafatsa ts'ireletso ea ts'ebetso le boiketlo. The pad-transformer e kentsoeng e hoketsoe ho marang-rang 'me e jara ka lithapo tsa ka tlas'a lefatše. Moralo ona o matlafatsa polokeho le ho fokotsa likotsi tse amanang le ho phatloha ho hoholo kapa liketsahalo tse khutšoane- tsa potoloho. Pad mounted transformer e sebelisoa haholo phepelong ea motlakase ea masepala, meaho ea khoebo, meaho ea bolulo le lirapeng tsa boikhathollo tsa indasteri, e fana ka matla a tsitsitseng bakeng sa lisebelisoa le lits'ebeletso tse fapaneng. Moetso oa pad-o thusa ho lokisoa 'me o na le mekhoa e fapaneng ea tšireletso, joalo ka tšireletso e ngata haholo le ts'ireletso e khutšoane-ea potoloho.
1.2 Tlhaloso ea Setsebi
Litlhaloso tsa mofuta oa 300 KVA le leqephe la data
|
E fetisetsoa ho
China
|
|
Selemo
2024
|
|
Mofuta
Transformer e kentsoeng ka pampiri
|
|
Standard
ANSI Standard
|
|
Rated Power
300 kVA
|
|
Khafetsa
60 HZ
|
|
Mokhahlelo
3
|
|
Fepa
Loop
|
|
Pele
E shoeleng
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
34.5GrdY/19.92 kV
|
|
Motlakase oa bobeli
0.12/0.208 kV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Angular displacement
YNyn0
|
|
Tšitiso
5%(±7.5%)
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
0.46KW
|
|
Ho Lahleheloa ke Moroalo
4.675KW
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
300 kVA pad mounted transformer diagram to the size and size.
![]() |
![]() |
02 Tlhahiso
2.1 Konokono
Transformer core ke karolo ea bohlokoa ea transformer, eo mosebetsi oa eona oa mantlha e leng ho fana ka -tahlehelo ea tsela ea makenete ho matlafatsa tšebetso ea makenete ea motlakase ea transformer. Moko oa mantlha ka tloaelo o entsoe ka lishiti tse ngata tse tšesaane tsa laminated tsa tšepe, sebopeho se etselitsoeng ho fokotsa tahlehelo ea hona joale ea eddy. Hangata maqephe ana a entsoe ka tšepe ea silicon, e nang le matla a matla a khoheli le thepa e ntle ea ho pata. Sebopeho sa motheo oa transformer ha se ame feela katleho ea transformer empa hape se ama bokhoni ba sona le botsitso. Nakong ea ts'ebetso, mokokotlo o hlahisa matla a khoheli ka ho fapanyetsana hona joale, ho nolofalletsa phetisetso ea matla le phetoho.

2.2 Ho tsubella

Ho ipapisitsoe le litlhoko tsa motlakase oa ho kenya le ho tsoa ho transfoma, bala karo-karolelano ea ho chenchana bakeng sa windings ea mantlha le ea bobeli. Moralo oa karo-karolelano ea li-turn o ama ka kotloloho tekanyo ea motlakase oa transformer le phetolo ea matla. Sebelisa metjhini e tsoelipanang ka boiketsetso ho netefatsa ho ts'oana le ho ts'oana ha mapheo. Ho bohlokoa ho etsa bonnete ba hore tlhophiso ea matsoelintsoeke e tiile ebile ha e na ho tšela. Eketsa lisebelisoa tsa ho itšehla thajana lipakeng tsa mekhahlelo e fapaneng ho netefatsa ts'ebetso ea insulation lipakeng tsa mekhahlelo.
2.3 Tanka
Tanka ea oli e entsoe ka lisebelisuoa tsa tšepe 'me e thibela ho bola-'me bokantle ba eona bo apesitsoe ka mafome-pente e manganga. Sebopeho sa eona se khutlonnetsepa, se etselitsoe ho netefatsa-matla a ho jara le botsitso ho mamella likhatello tsa tikoloho tse kantle. Tanka ea oli e tletse oli e sireletsang, e sebeletsang ho pholile le ho kenya letsoho. Nakong ea ts'ebetso, oli e monya mocheso o hlahisoang ke li-winding le mantlha, 'me e qhala mocheso ka convection ea tlhaho kapa potoloho e qobelloang. Tanka e entsoe ka thepa e ntle ea ho koala ho thibela tšilafalo ea tikoloho le ho lutla ha oli, 'me e na le li-valve tsa polokeho, li-gauge tsa khatello le lisebelisoa tse ling ho netefatsa ts'ebetso e bolokehileng.

2.4 Kopano ea ho Qetela

Tokisetso ea Karolo: Netefatsa hore likarolo tsa bohlokoa joalo ka sekontiri sa transformer, windings, le tanka ea oli li lokile.
Kopanya Tanka ea Oli: Lokisa tanka ea oli e phekotsoeng sebakeng sa eona 'me u kenye li-gaskets tse koalang ho thibela ho tsoa ha oli.
Kenya Core le Windings: Beha setsi sa transformer ka har'a tanka ea oli 'me u kenye li-windings, ho etsa bonnete ba ho lumellana hantle le ho tiisa ka mokhoa o sireletsehileng.
Hokela Lithapo: Hokela lithapo tse phahameng-le lithapo tsa motlakase tse tlase-, u sebelisa lisebelisoa tse sireletsang tšireletso ho netefatsa polokeho.
Tlatsa ka Oli le Vent: Tlatsa tanka ea oli ka oli e sireletsang, tlosa moea le ho netefatsa boleng ba oli.
03 Ho etsa liteko
(1) Teko e tloaelehileng
a) Karo-karolelano mabapi le likhokahano le maemo a pompo
b) Ho falla ka mahlakoreng
c) Ha ho{0}}tahlehelo ea mojaro ka 100% ea matla a matla a motlakase
d) Nako e thabisang ka 100% ea motlakase o lekantsoeng
e) Litahlehelo tsa meroalo le tšitiso ka nako e lekantsoeng
f) Matla a motlakase a sebelisitsoeng
g) Matla a matla
h) Teko ea ho lemoha ha tanka e lutla-
i) Teko ea ho tsoelapele
(2) Mofuta oa teko
a) Ho hanyetsa
b) Ho phahama ha mocheso
c) Matla a tshusumetso
d) Radio{0}}e susumetsang motlakase
f) Botšepehi ba Transformer
g) Molumo o utloahalang oa mantlha
h) Ho mamella khatello e mpe


04 Ho paka le ho Romela


05 Sebaka le Kakaretso
Qetellong, -mohato o tharo-mofetoleli o phahamisitsoeng o bapala karolo ea bohlokoa lits'ebetsong tsa sejoale-joale tsa ho tsamaisa motlakase, ho fana ka ts'epahalo le ts'ebetso ea phano ea motlakase. Moralo oa eona o matla le theknoloji e tsoetseng pele e netefatsa ts'ebetso e nepahetseng ha e ntse e fokotsa tahlehelo ea matla le tšusumetso ea tikoloho. Ka liteko tse matla le lits'ebetso tsa netefatso ea boleng, li-transformer tsena li hahiloe ho mamella maemo a boima le ho fana ka ts'ebeletso e bolokehileng, e ts'epahalang nakong ea ts'ebetso ea tsona. Ha re ntse re tsoela pele ho ntlafatsa litlhoko tsa rona tsa matla, -mohato o meraro-sefetoleli se phahamisitsoeng se eme e le karolo ea bohlokoa ho ntlafatseng lits'ebetso tsa rona tsa motlakase, ho ts'ehetsa phetoho ho litharollo tsa matla tsa nako e tlang.

Hot Tags: pad{{0}sefetoleli, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
250 kVA Pad Mounted Transformer-23/0.4 kV|Chile 2024
5 MVA Pad Mount Transformers-33/0.48 kV|USA 2025
400 kVA Padmount Transformer-23 / 0.4 kV|Chile 2024
2500 kVA Pad Mounted Transformer-13.2/0.48 kV|Canada...
1250 kVA Pad Mounted Transformer-12.47/0.6 kV|Sebe...
2500 kVA Pad Mount Transformer-12.47/0.48 kV|USA 2025
Romela Inquiry