1000 kVA Pad Mounted Transformer List-13.8/0.415 kV|Jamaica 2024

1000 kVA Pad Mounted Transformer List-13.8/0.415 kV|Jamaica 2024

Naha: Jamaica 2024
Matla: 1000kVA
Matla: 13.8/0.415kV
Feature: e nang le sehokelo sa ho itšehla thajana
Romela Inquiry

 

 

pad mounted transformer price list

Motlakase o sebetsang hantle, o tiileng joalo ka rock--mehato e meraro{2}e kentsoeng li-transformer, molekane oa hau ea tšepahalang!

 

01 Kakaretso

1.1 Semelo sa Morero

Transformer ena ea 1000 kVA Pad mounted e ile ea isoa Jamaica ka 2024. Matla a lekantsoeng a transformer ke 1000 kVA, ka motlakase oa mantlha oa 13.8D kV ho ea ho motlakase oa bobeli 0.415y / 0.24 kV. Sehlopha sa likhokahano ke Dyn1, pad mounted transformer ke sete ea taolo e phahameng ea{8}voltage, tšireletso, phetolo ea motlakase, le lisebelisoa tsa ho ajoa ho e 'ngoe ea lihlopha tse felletseng tsa{9}lihlahisoa tse kentsoeng, tse sebelisoang haholo libakeng tsa litoropo le mahaeng. Sehlahisoa se beha switch{11}}molumo oa motlakase o phahameng le{12}}fuse ea matla a phahameng ka har'a oli ea transfoma, 'me se na le mefuta e 'meli ea tlhophiso ea{13}}mabokoso kapa lebokose le arohaneng le 'mele oa transformer. Tanka ea oli e tiisitsoe ka ho feletseng 'me e na le tekanyo ea mocheso oa oli, tekanyo ea boemo ba oli, tekanyo ea khatello, valve ea ho fokotsa khatello, valve ea liphallelo le likarolo tse ling ho lekola tšebetso ea transformer. Sehlahisoa se arotsoe ka mofuta oa marang-rang oa lesale, mofuta oa terminal le mokhoa oa phepelo ea matla. E sebetsa lifemeng, merafong, masimong a oli, likoung, boema-fofane, meaho ea sechaba ea litoropong, libaka tsa bolulo, litsela tse kholo, lits'ebeletso tse ka tlas'a lefatše le libaka tse ling.

 

 

1.2 Tlhaloso ea Setsebi

1000 kVA lintlha tsa mofuta oa li-transformer le leqephe la data

E fetisetsoa ho
Jamaica
Selemo
2024
Mofuta
Transformer e kentsoeng ka pampiri
Standard
IEEE C57.12.00
Rated Power
1000kVA
Khafetsa
50 HZ
Mokhahlelo
3
Fepa
Loop
Pele
E shoeleng
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
13.8D kV
Motlakase oa bobeli
0.415y/0.24 kV
Lintho Tse Hlahang
Koporo
Angular displacement
Dyn1
Tšitiso
4.75%
Katleho
99.15%
Tlanya Changer
NLTC
Mokelikeli o thibelang metsi
Oli ea liminerale
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
Ka tlase ho kapa ho lekana le 1.3KW
Ho Lahleheloa ke Moroalo
Ka tlase ho kapa ho lekana le 13.2KW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

1000 kVA pad mounted transformer diagram to the size and size.

transformer simple drawing transformers pencil drawing

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Bohareng ba-mohato oa boraro-columne transformer e entsoe ka likotoana tse 6 ho lera, 'me kopanyo ea punch ea mekhahlelo e 'ngoe le e 'ngoe e sebelisa litlhophiso tse fapaneng ho sisinya manonyeletso a potoloho ea makenete ea lea le leng le le leng. Mokhoa ona oa kopano o bitsoa kopano e fetang, 'me kopano ena e ka qoba ho potoloha ha maqhubu a eddy pakeng tsa letlapa la tšepe le lesela la tšepe. 'Me kaha karolo e' ngoe le e 'ngoe ea ho phunya e lohiloe, ho ka sebelisoa li-fasteners tse fokolang ho etsa hore mohaho o be bonolo ha o hatella mokokotlo oa tšepe. Nakong ea kopano, lipoleiti tsa ho phunya li qala ho phutheloa ho etsa motheo oa tšepe kaofela, ebe joko e ka tlaase ea tšepe e tlamisoa, letlapa le ka holimo la tšepe la joko le tlosoa ho pepesa kholomo ea mantlha, ho behoa ho tsoetsoeng pele ho behoa holim'a kholomo ea mantlha, 'me qetellong ho kenngoa poleiti e ka holimo ea tšepe e ntšitsoeng.

ei transformer core

 

2.2 Ho tsubella

Dyn1 connection

Khokahano ea Dyn1 ke mokhoa o tloaelehileng oa ho hokela li-transformer, haholo-holo o bolelang tšebeliso ea naleli (Y) khokahanyo ho hokela khokahanyo e tlase-ea maqhubu a motlakase le a kgutlotharo (Δ) ho hokahanya maqhubu a phahameng-ka li-voltage tse tharo{3}}ka li-transformer tsa mekhahlelo e meraro, le mokhahlelo oa tlase{4}}voltage side e salletse ka morao{5} voltage phase by 1 Khokahanong ea Dyn1, karolo ea lehlakore la khatello e tlase e salla ka morao ho lehlakore la khatello e phahameng ka Angle ea 1 phase (120 degree). Likamano tsa mohato ona li thusa ho fumana ho leka-lekana ha mojaro hantle-karolo ea mekhahlelo e meraro le ho fokotsa mathata a bakoang ke phase asymmetry. Hobane khokahano ea naleli e ka fana ka ntlha e itseng ea ho se nke lehlakore, khokahano ea Dyn1 e ka hatella hantle li-harmonics tse ling, haholoholo tsa boraro, e le ho ntlafatsa boleng ba matla a sistimi. Ntho e sa nke lehlakore ea ho hokahanya ha linaleli e ka thehoa, e ka ntlafatsang tšireletso ea tsamaiso le ho fana ka tšireletso e molemo bakeng sa lisebelisoa le basebetsi. Ho phaella moo, lisebelisoa li sirelelitsoe hamolemo ho senya ha ho e-na le phoso ea fatše. Khokahano ea Dyn1 e loketse mefuta e mengata ea mojaro, ho kenyeletsoa meroalo e mehala le e sa reroang. Mokhoa ona oa ho hokahanya o ka boela oa boloka ts'ebetso e ntle ea ts'ebetso tlas'a maemo a sa leka-lekaneng a mojaro. E lumella mefuta e fapaneng ea likhakanyo tsa phetoho ea motlakase, e le hore khokahano ea Dyn1 e ka fetoloa habonolo lits'ebetsong tse fapaneng ho ikamahanya le litlhoko tse fapaneng tsa motlakase.

 

2.3 Tanka

Lebokose le ka sebelisa mokhoa o thibelang -moetso oa ho senya le ho penta ka mokhoa o khethehileng oa ho penta ho ea ka litlhoko tsa tikoloho ea ts'ebetso, ka ts'ebetso ea "thibelo{1}}ea condensation" e meraro, ke hore, -sets'oants'o sa letsoai, se thibelang{3}}mould, 'me se ka khotsofatsa litlhoko tse thibelang{4}}khoho ho mocheso o phahameng le tikoloho ea mongobo o phahameng. Tanka e tiisitsoeng ka botlalo, moralo o sirelelitsoeng ka botlalo, ts'ebetso e bolokehileng le e tšepahalang.

outdoor oil tank

 

2.4 Kopano ea ho Qetela

Seal the transformer enclosure

Lihokelo tsa Motlakase: Tlatsa likhokahano tsa ka hare bakeng sa lithapo tse phahameng{{0}le tsa motlakase{1} tse tlase{1}, ho netefatsa hore lithapo li tsamaisana hantle lipakeng tsa mekhahlelo.

Tlhahlobo ea Tsamaiso ea Pholiso: Lekola boemo ba oli le likarolo tsa sistimi e pholileng ho netefatsa hore li sebetsa hantle.

Teko ea Insulation: Etsa liteko tsa ho kenya letsoho ho netefatsa hore likhokahano tsa motlakase li kopana le litekanyetso tsa polokeho bakeng sa ts'ebetso ea insulation.

Ho Tiisa Lekaela: Tiisa sekoahelo sa transformer, ho etsa bonnete ba hore manonyeletso le litiiso tsohle li tiile ho thibela mongobo le litšila ho kena.

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Litekanyo tsa ho hanyetsa

%

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane Ka tlase kapa ho lekana le 5%

1.68

Feta

2

Liteko tsa karo-karolelano

%

Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5%

Letšoao la khokahano: Dyn1

-0.08% ~- 0.06%

Feta

3

diteko- tsa dikamano

/

Dyn1

Dyn1

Feta

4

Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale

%

kW

I0: fana ka boleng bo lekantsoeng

P0: fana ka boleng bo lekantsoeng

mamello ea ho se lahleheloe ke moroalo ke +0%

0.48%

1.123

Feta

5

Litahlehelo tsa tahlehelo ea matla a motlakase le katleho

%

kW

kW

T:85 likhato

Z%: boleng bo lekantsoeng

Pk: boleng bo lekantsoeng

Pt: boleng bo lekantsoeng

mamello bakeng sa impedance ke ± 7.5%

mamello ea tahlehelo ea boima kaofela ke +0%

Katleho e seng ka tlase ho 99.15%

4.89%

11.900

13.023

99.24%

Feta

6

Teko ea Voltage e sebelisitsoeng

kV

HV: 34kV 60s

LV: 10kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea ho mamella Voltage e kentsoeng

kV

Matla a sebelisoang (KV):

2 Ur

Nako:40

Hangata (HZ): 150

Ha ho ho putlama ha motlakase oa liteko

Feta

8

Leakage Test

kPa

Khatello e sebelisitsoeng: 20kPA

Nako: 12h

Ha ho na leakage le che

Tšenyo

Feta

9

Tekanyo ea ho hanyetsa Insulation

HV{{0}LV ho ea fatše:

LV-HV ho ea fatše:

HV&LV ho ea fatše:

20.4

35.1

18.3

/

10

Teko ea Dielectric ea Oli

kV

E kholo ho feta kapa e lekana le 45

56.83

Feta

 

1000kva Resistance Measurements
1000kva Induced Voltage Withstand Test

 

 

04 Ho paka le ho Romela

transformer package price
1000kva transformer transport price

 

 
 

05 Sebaka le Kakaretso

Boemong ba tlhokahalo e ntseng e hola ea motlakase le tsoelo-pele e potlakileng ea mahlale a morao-rao, transfoma e kentsoeng ka mekhahlelo e meraro e u fa tharollo ea matla e sebetsang hantle le e tšepahalang. Ka ts'ebetso ea eona e ikhethang, moralo o kopaneng, le ho ikamahanya le maemo ho ikhethang, sehlahisoa sena ha se fihlelle litlhoko tse fapaneng tsa motlakase feela empa hape se netefatsa ts'ebetso e tsitsitseng tlasa maemo a fapaneng a tikoloho. Ka ho khetha karolo ea rona e meraro ea li-pad pad mounted transformer, u tla rua molemo ho netefatso ea boleng bo ikhethang le melemo ea nako e telele-ea moruo. Re tla tsoelapele ho khothaletsa boqapi ba theknoloji le lits'ebeletso tse hloahloa, ho thusa sistimi ea hau ea matla ho nts'etsapele hantle, ka polokeho le ka mokhoa o tsitsitseng. Ke leboha tšepo le tšehetso ea hau!

long-term economic advantages

 

 

Hot Tags: Lenane la theko ea li-transformer tse kentsoeng, moetsi, mofani oa thepa, theko, litšenyehelo