75 kVA Pad Mount Transformer-22.86/0.208 kV|USA 2024

75 kVA Pad Mount Transformer-22.86/0.208 kV|USA 2024

Naha: Amerika 2024
Matla: 75kVA
Matla: 22.86/0.208kV
Sebopeho: ka IFD
Romela Inquiry

 

 

75 kva pad mount transformer with ifd

Matla a tsitsitseng, khetho e bohlale – Tse tharo-Phase Pad{{1}Mounted Transformer e netefatsa ho sebetsa hantle ha matla le polokeho!

 

01 Kakaretso

1.1 Semelo sa Morero

Sebopeho sa 75 kVA pad mounted transformer se ile sa isoa Amerika ka 2024. Matla a lekantsoeng a transformer ke 75 kVA e nang le pholiso ea ONAN. Motlakase oa mantlha ke 22.86GRDY/13.2kV ​​e nang le ± 2 * 2.5% tapping range (NLTC), motlakase oa bobeli ke 0.48y / 0.208kV, ba thehile sehlopha sa vector sa YNyn0, 'me ke lijo tsa loop le transformer e ka pele e shoeleng. Lebokose la li-transformer tse kentsoeng ka mekhahlelo e meraro tse hlahisitsoeng ke SCOTECH haholo-holo li entsoe ka setsi, liphanele tse mahlakoreng, likaroloana, mamati le likoahelo tse kaholimo. Lebokose le arotsoe ka kamoreng ea khatello e phahameng, kamore ea transformer le kamore e tlaase ea khatello. Mohaho o phahameng oa motlakase o sebelisa moralo o phethahetseng oa khokahanyo, o nang le tšebetso e matla e thibelang{14}mesebetsi e sa sebetseng hantle, e ts'epahalang haholo, ho hlokomeloa ha bonolo, switchgear ea motlakase e phahameng e ka sebelisoa terminal load switch, ring network switchgear joalo-joalo. Kamore ea transformer e ka kengoa ka oli{16}}transformer e qoelitsoeng kapa e omeletseng, 'me e na le letlooa le sireletsang motho a le mong, phaposi ea transfoma e ka amohela moea oa tlhaho kapa moea o qobelloang, ho latela tlhoko ea ho kenya mochine o laolang mocheso, ho hlahloba mocheso oa kamore le sesebelisoa sa moea o ikemetseng. The low{18}voltage chamber e na le distribution, metering, reactive power compensation and other standard schemes, mme e ka etsa the secondary control loop le palo ea lithapo ho ea ka litlhoko.

 

 

1.2 Tlhaloso ea Setsebi

Litlhaloso tsa mofuta oa 75 kVA le leqephe la data

E fetisetsoa ho
Amerika
Selemo
2024
Mofuta
Transformer e kentsoeng ka pampiri
Fepa
Loop
Pele
E shoeleng
Standard
IEEE C57.12.34
Rated Power
75kVA
Khafetsa
60HZ
Mokhahlelo
3
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
22.86GRDY/13.2 kV
Motlakase oa bobeli
0.48y/0.208 kV
Lintho Tse Hlahang
Aluminium
Angular displacement
YNyn0
Tšitiso
E kholo ho feta kapa e lekana le 2.7%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
0.28KW
Ho Lahleheloa ke Moroalo
1.07KW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

75 kVA pad mounted transformer diagram to the size and size.

75 kva pad mount transformer image005

 

 

02 Tlhahiso

2.1 Konokono

Boraro-mohato oa bohlano-moko oa kholomo o na le litšiea tse hlano, hangata litšiea tse tharo li sebelisoa ho tsamaisa mekhahlelo e meraro-mohato oa A, B, C), ha litšiea tse ling tse peli li sebetsa e le khokahano le sebopeho sa tšehetso. Moralo oa potoloho ea makenete oa kholomo ka 'ngoe e etselitsoe ho ntlafatsa khokahanyo le tšebetso ea-mohato oa boraro. Moralo ona o ka aba le ho laola mehato e meraro{6}}le ho fokotsa tšitiso lipakeng tsa mekhahlelo. Ho hlophisoa ha litšiea tse hlano ho etsa hore ho ka khoneha hore ho be le phallo ea matla a khoheli e laoloang ka katleho, 'me ka nako e ts'oanang e ntlafatsa ho phunyeletsa le ho sebetsa hantle ha motheo. Li-cores tsa tšepe hangata li entsoe ka symmetry kelellong ho fihlela kabo e tšoanang ea matla a khoheli. Moralo o ts'oanang oa motheo oa tšepe o ka fokotsa ka katleho tahlehelo e bakoang ke ho se leka-lekane ha matla a khoheli le ho ntlafatsa botsitso ba ts'ebetso le ts'ebetso ea motlakase ea lisebelisoa. Mehato e meraro-e ka aroloa ka ho lekana likholomong tse tharo ho theha libaka tse tharo tsa makenete tse hokahaneng. Sebopeho sena se tiisa khokahanyo e ntle ea flux le ho ntlafatsa phetiso ea matla.

three-phase five-column core

 

2.2 Ho tsubella

aluminum winding

Tšebeliso ea aluminium-e phahameng ea conductivity e ka fokotsa ho hanyetsa ha matsoelintsoeke, kahoo ea fokotsa tahlehelo ea mohala le ho ntlafatsa ts'ebetso ea kakaretso ea transfoma. Tšebeliso ea thepa e sireletsang e ka thibela ka katleho potoloho e khutšoanyane le ho phalla pakeng tsa windings le ho ntlafatsa ts'ebetso ea ts'ebetso ea transformer. Theknoloji ea matsoelintsoeke e ka etsa bonnete ba hore palo ea ho phethoha ha mapheo e ajoa ka mokhoa o ts'oanang, e ka ntlafatsang kabo ea matla a khoheli le ho ntlafatsa bokhoni ba ho kopanya ha transformer. Ka moralo o utloahalang oa sebopeho sa matsoelintsoeke, hona joale ho ka ajoa ka mokhoa o ts'oanelang ho potoloha, ho fokotsa libaka tse chesang tsa lehae le ho fokotsa mocheso. Ka ho fetola palo ea ho chenchana ha maqhubu, tekanyo ea motlakase ea transformer e ka fetoloa, e le hore e ka sebelisoa habonolo tlas'a maemo a fapaneng a ho sebetsa. Mokhoa oa tlhahiso ea theknoloji ea maqeba a terata e batla e hōlile, e ka fokotsang potoloho ea tlhahiso le ho rarahana ha tlhahiso, kahoo e fokotsa litšenyehelo.

 

2.3 Tanka

-litšepe tsa boleng bo holimo li khethoa e le thepa ea tanka ea mafura ho netefatsa hore tanka ea mafura e khona ho mamella khatello le ho senyeha ha kutu. Letlapa la tšepe le khaotsoe hantle ho latela litšoantšo tsa moralo, hangata ho sebelisoa mechini ea ho itšeha, ho itšeha ka laser kapa mekhoa ea ho itšeha ka plasma. Poleite e sehiloeng ea tšepe e bentšitsoe, ha ea silafatsoa 'me ea rusa-bopaki ba ho ntlafatsa boleng ba li tjheseletsa le ho khomarela ha coating e latelang. Letlapa la tšepe le sehiloeng le phuthetsoe le ho etsoa ho ea ka litlhoko tsa moralo bakeng sa welding ea pele, hangata ho sebelisoa argon arc welding, CO₂ shielded welding kapa submerged arc welding le mekhoa e meng ea welding. Ka mor'a hore welding e phethoe, weld e hlahlojoa, ho kenyelletsa le tlhahlobo ea pono le tlhahlobo ea ultrasonic, ho netefatsa boleng ba ho cheselletsa. Sebedisa-matla a ho tiisa a boleng bo hodimo (jwalo ka digasekete tsa rabara le di-sealant) manonyeletsong le manonyeletsong a tanka ya mafura ho etsa bonnete ba hore tanka ya mafura e sebetsa hantle. Phekolo e thibelang mafome{9}ka holim'a tanka, hangata ka ho sebelisa pente e ka tlase, ebe o fafatsa pente e khahlano le litlhoko tsa ts'ireletso ea tikoloho ho fana ka ts'ebetso e ntle ea{10}ea kutu.

75 kva pad mount transformer stainless steel oil tank

 

2.4 Kopano ea ho Qetela

75 kva pad mount transformer final assembly
75 kva 3 phase pad mount transformer

 

 

03 Ho etsa liteko

Che.

Ntho ea Teko

Yuniti

Kamohelo

Litekanyetso

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Litekanyo tsa ho hanyetsa

%

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane Ka tlase kapa ho lekana le 5%

1.16

Feta

2

Liteko tsa Karolelano

%

Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5%

-0.04~-0.02

Feta

3

diteko- tsa dikamano

/

YNyn0

YNyn0

Feta

4

Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale

/

I0 : fana ka boleng bo lekantsoeng

0.33%

Feta

P0: fana ka boleng bo lekantsoeng

0.062kW

mamello ea ho se lahleheloe ke moroalo ke +10%

/

5

Litahlehelo tsa tahlehelo ea matla a motlakase le katleho

/

t: likhato tse 85

mamello bakeng sa impedance ke ± 7.5%

mamello ea tahlehelo ea boima kaofela ke +6%

/

Feta

Z%: boleng bo lekantsoeng

3.65%

Pk: boleng bo lekantsoeng

1.168kW

Pt: boleng bo lekantsoeng

1.230kW

Katleho e seng ka tlase ho 99.03%

99.14%

6

Teko ea Voltage e sebelisitsoeng

kV

LV: 10kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea ho mamella Voltage e kentsoeng

kV

Matla a sebelisoang (kV): 40

Ha ho ho putlama ha motlakase oa liteko

Feta

Nako: 48

Hangata (HZ): 150

8

Leakage Test

kPa

Khatello e sebelisitsoeng: 20kPA

Nako: 12h

Ha ho na leakage le che

Tšenyo

Feta

9

Tekanyo ea ho hanyetsa Insulation

LV-HV ho ea fatše

85.2

/

10

Tlhahlobo ea oli

/

Matla a Dielectric;

56.1 kv

Feta

Mongobo

9.7 mg / kg

Ntho ea ho senya

0.00327%

Furan Analysis

0.03 mg/kg

Tlhahlobo ea Khase ea Chromatography

/

 

75 kva pad mount transformer testing
75 kva pad mount transformer test

 

 

04 Ho paka le ho Romela

75 kva pad mount transformer tin foil bag
75 kva pad mount transformer shipping
 
 

 

05 Sebaka le Kakaretso

Karolo e meraro ea 75 kVA pad Mount transformer, e nang le ts'ebetso e ntle haholo, boleng bo tšepahalang, le lits'ebetso tse fapaneng, ke khetho e nepahetseng bakeng sa lits'ebetso tsa sejoale-joale tsa kabo ea motlakase. Ebang ke litsing tsa khoebo, lirapeng tsa boikhathollo tsa indasteri, kapa lisebelisoa tsa sechaba, sehlahisoa sena se kopana hantle le litlhoko tse fapaneng tsa motlakase, ho netefatsa botsitso ba sistimi le ho eketsa tšebeliso ea matla. Khetha Three Phase Pad Mounted Transformer ho etsa hore sistimi ea hau ea matla e sebetse hantle le ho tšepahala, e fane ka tšehetso e matla bakeng sa nts'etsopele ea moshoelella nakong e tlang.

three phase 75 kva pad mount transformer

 