370 kVA Grounding A Transformer-22/0.11 kV|Afrika Boroa 2024
Matla: 370kVA
Matla: 22/0.11kV
Tšobotsi: e nang le CT

Motheo o tšepahalang, phepelo ea motlakase e tsitsitseng{0}khetha li-transformer tse ikhethang!
01 Kakaretso
1.1 Semelo sa Morero
Transformer ena ea 370kVA earthing e romelloa Afrika Boroa ka Phato, 2024. Motlakase oa mantlha ke 22 kV, motlakase oa bobeli ke 0.11 kV, transformer e na le mochine o se nang mochini oa ho fetola thepa, sebaka sa ho phunya ke ± 2 * 2.5% ka lehlakoreng la mantlha, ho pholisa ke ONAN.
Tsamaisong ea matla, transformer ea fatše ke transformer e khethehileng, e na le boikarabelo ba bohlokoa ba ho sireletsa lisebelisoa, tšireletso ea botho le ho ntlafatsa ho tšepahala ha phepelo ea matla. Transformer ea fatše e hlokomela motheo o sebetsang oa ntlha ea ho se nke lehlakore ka mokhoa o bohlale oa ho sebetsa, ebe o felisa tšusumetso ea hona joale e sa leka-lekaneng tsamaisong.
Sepheo sa transformer ea fatše ke ho fana ka ntlha ea maiketsetso ea ho se nke lehlakore bakeng sa tsamaiso moo ntlha e sa jeleng paate e sa thehoang fatše, le ho nolofatsa tšebeliso ea li-coil tsa khatello ea arc kapa mekhoa e menyenyane ea ho thibela fatše. Molao-motheo oa eona oa ts'ebetso ke haholo-holo ho theola ntlha e sa jeleng paate tsamaisong le ho hlahisa motlakase o sa tsitsang fatše, e le ho finyella tšireletso le ts'ebetso e sireletsehileng ea tsamaiso. Tlas'a maemo a tloaelehileng, ntlha e sa jeleng paate ea mobu oa mobu ha e theohe, empa ha phoso ea tsamaiso e etsa hore mocheso oa ntlha o sa nke lehlakore o phahame, mochine oa fatše o tla phetha karolo. Ha motlakase o sa nke lehlakore o phahama ho isa tekanyong e itseng, transformer ea fatše e tla bulela le ho theola ntlha e sa jeleng paate, ka tsela eo e hlahisa mocheso o sa leka-lekaneng fatše, ho thibela motlakase ho tsoela pele ho phahama, le ho sireletsa lisebelisoa tsa tsamaiso le polokeho ea motho.
1.2 Tlhaloso ea Setsebi
Litlhaloso tsa mofuta oa 370 kVA le leqephe la data
|
E fetisetsoa ho
amerika e boroa
|
|
Selemo
2024
|
|
Mofuta
Transformer ea mobu
|
|
Standard
IEC-60076
|
|
Rated Power
370kVA
|
|
Khafetsa
50HZ
|
|
Mokhahlelo
3
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
22 kV
|
|
Motlakase oa bobeli
0.11 kV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Angular displacement
ZN
|
|
Tšitiso
3%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
0.491KW
|
|
Ho Lahleheloa ke Moroalo
1.27KW
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
370 kVA sets'oants'o sa sets'oants'o sa lefats'e le boholo.
![]() |
![]() |
02 Tlhahiso
2.1 Konokono
Motheo oa transformer ea fatše o entsoe ka letlapa la tšepe la silicon, le nang le tahlehelo e tlaase ea hysteresis le tahlehelo ea hona joale ea eddy, e thusang ho ntlafatsa matla a matla a transformer. Ka moralo, sebopeho sa mantlha hangata se koetsoe ka loop e le ho theha phallo e tsitsitseng ea makenete le ho fokotsa ho lutla ha makenete.
Ka transformer e thehiloeng fatše, mosebetsi o ka sehloohong oa mantlha ke ho fana ka tsela e ntle ea ho phalla, e le hore transformer e ka khona ho itšehla thajana le ho fetola motlakase. Ka nako e ts'oanang, motheo o boetse o thusa ho tsamaisa hona joale ho lutla ho transformer ho tsamaiso ea fatše, kahoo ho ntlafatsa polokeho ea tsamaiso. Ka moralo o hlakileng oa mantlha, lerata le ho thothomela li ka fokotsoa ka nepo, 'me botsitso ba ts'ebetso ea lisebelisoa bo ka ntlafatsoa.
E le ho matlafatsa -bokhoni ba ho kena-kenana le matla a motlakase a transformer ea fatše, bokahare ba motheo hangata bo phekoloa ho fokotsa tahlehelo ea hona joale ea eddy le ho ntlafatsa ho hanyetsa botsofali. Ntle le moo, mehato e nkuoa nakong ea ts'ebetso ea tlhahiso ho fokotsa lekhalo la moea bohareng ho ntlafatsa thepa ea eona ea makenete le ho fihlela katleho e phahameng ea mosebetsi. Ka kakaretso, motheo oa tšepe oa transformer ea fatše hase feela tiiso ea ts'ebetso ea motlakase, empa hape ke karolo ea bohlokoa ea ho netefatsa ts'ebetso e sireletsehileng le e ka tšeptjoang ea lisebelisoa.
2.2 Ho tsubella
Coil winding ea transformer ke sehokelo sa mantlha mohahong oa eona, se amang ka kotloloho ts'ebetso ea motlakase le katleho ea transformer. Hangata li-coil li entsoe ka terata ea koporo e tsamaisang haholo kapa ea aluminium ho netefatsa hore ho na le conductivity e ntle ea hajoale le tahlehelo e tlase ea matla. The matsoelintsoeke mokhoa oa khoele ka kakaretso lera matsoelintsoeke kapa concentrated matsoelintsoeke, e leng ka ka katleho fokotsa ho hanyetsa le inductive reactance ea khoele le eketsa segokanyipalo matla a transformer.
Ha ho etsoa matsoelintsoeke, palo ea ho chenchana le ho hlophisoa ha coil e na le phello ea bohlokoa ho tekanyo ea motlakase, katleho ea ho fetola matla le phepelo ea phallo ea transformer. E le ho ntlafatsa ts'ebetso ea li-coil, moqapi o tla bala ka nepo palo ea ho fetoha ha sete e 'ngoe le e' ngoe ea li-coil ho latela litlhoko tsa kopo ea transformer ho netefatsa hore e ka finyella phetoho e hlokahalang ea motlakase. Ho phaella moo, ho kenngoa ha coil ho boetse ho bohlokoa haholo, 'me lisebelisoa tse sebelisoang hangata li kenyelletsa resin ea epoxy, pampiri le filimi ea polyester ho thibela potoloho e khutšoanyane le ts'ebetso ea ho lutla.

2.3 Tanka

Litanka tsa oli li na le mohaho o tiisitsoeng ho thibela moea o ka ntle le litšila ho kena, ho boloka bohloeki ba oli ea transformer. 'Mele oa tanka o kopantsoe ka likhokahano tse cheselitsoeng kapa tse bolted ho netefatsa matla a holimo le tiiso e tiileng. Ka ntle ho ts'oaroa ka liphahlo tse khethehileng ho ikamahanya le maemo a leholimo a fapaneng le maemo a ho kenya, joalo ka mongobo o phahameng, moea o letsoai kapa tšilafalo ea indasteri.
2.4 Kopano ea ho Qetela


03 Teko
1. Mefuta ea Liteko
● Teko ea Ho Phahamisa Mocheso: E netefatsa hore ho phahama ha mocheso ho ka har'a meeli e lumelletsoeng.
● Teko e Khutšoanyane- ea Tšitiso ea Potoloho le Tahlehelo ea Moroalo: E lekanya-mehaello ea potoloho le tahlehelo ea thepa.
● Ha ho-Tahlehelo ea Mojaro le Teko ea Hona Joale: E lekola ts'ebetso e sebetsang nakong ea-ha ho sa kenye tšebetsong.
● Teko ea Ts'ebetso ea Insulation: E leka matla a motlakase a tsamaiso ea ho kenya letsoho.
2. Liteko tse tloaelehileng
● Tekanyo ea Khahlano ea DC: E hlahloba likhokahano tse matsoelintsoeke le boleng ba thepa.
● Phetoho ea karo-karolelano le Polarity Test: E netefatsa karolelano e nepahetseng le polarity.
● Matla a Maqhubu a Matla a Mamella Teko ea Voltage: E netefatsa bokhoni ba ho hanyetsa motlakase oa sistimi ea insulation.
● Teko ea ho Khanyetso ea Grounding: E netefatsa ts'ebetso e tsitsitseng ea motheo.
3. Liteko tse khethehileng
● Tlhahlobo ea Tšusumetso ea Lehalima: E etsisa ho otla ha lehalima ho netefatsa khanyetso ea insulation ho mats'oao.
● Teko ea Phallo e sa Feleng: E lemoha ho tsoa ka hare ka har'a tsamaiso ea ho pata.
● Teko ea Lerata: E lekanya lerata la ts'ebetso ho netefatsa hore e kopana le maemo.
● Teko e Khutšoanyane- ea Potoloho: E hlahloba matla a mochine le botsitso ba mocheso.
04 Ho paka le ho Romela


05 Sebaka le Kakaretso
Li-transformer tsa Earthing li khetholloa e le li-reactors tse tloaelehileng. Earthing transformer (neutral coupler) ke -mohato oa transfofoma ea mekhahlelo e meraro e hoketsoeng ho sistimi ea motlakase ho fana ka khokahano e sa nke lehlakore, e ka fihlellehang ka ho otloloha kapa ka ho sitisoa. Li-transformer tsa Earthing le tsona li ka fana ka meroalo e meng e thusang ea lehae.
Nakong ea-phoso e le 'ngoe, mochine o fokotsang phoso sebakeng se sa nke lehlakore 'me o ntlafatsa ho hlaphoheloa ha thapo ea motlakase. Ho ea ka IEC 60076-6, mochine oa fatše o kopantsoe pakeng tsa ntlha e sa jeleng paate ea tsamaiso ea matla le fatše e le ho fokotsa moeli oa mohala ho ea fatše ho ea bohlokoa bo lakatsehang ha ho e-na le phoso ea fatše tsamaisong.
Transformer ea lefatše e ka fana ka ntlha e sa jeleng paate ho marang-rang a matla. Hangata ho sebelisoa khokahano ea ZN. Khokahano ea Z-e fana ka linear le zero e khethehileng{3}}e thibelang tatellano. Transformer ea fatše e ka boela ea hokahanngoa ka mokhoa oa YN + d.