50 kVA Single Phase Pole Mounted Distribution Transformer-13.8/0.12/0.24 kV|Guyana 2025

50 kVA Single Phase Pole Mounted Distribution Transformer-13.8/0.12/0.24 kV|Guyana 2025

Naha: Guyana 2025
Matla: 50 kVA
Matla: 13.8-0.12/0.24kV
Tšobotsi: ka sesebelisoa sa ho imolla khatello
Romela Inquiry

 

 

single phase pole mounted distribution transformer

Maemo a Leholimo-Ha a Mamelle, a Lula Kamehla – Pole{{1}Mounted Transformers Ho Boloka Mabone a Khantšitse.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

50 kVA single phase pole mounted transformer e ile ea isoa Guyana ka 2025. Matla a lekantsoeng a transformer ke 50 kVA e nang le pholiso ea ONAN. Motlakase o ka sehloohong ke 13.8 kV e nang le ± 2 * 2.5% ho pata mefuta e mengata (NLTC), motlakase oa bobeli ke 0.12 / 0.24 kV, ba thehile sehlopha sa vector sa Ii0.

Pole ena ea 50 kVA-transformer e hlonngoeng e entsoe ho latela maemo a IEEE, e netefatsang ts'ebetso e tšepahalang le ho tšoarella lits'ebetsong tsa phepelo ea kantle. E na le moaho o matla o nang le likarolo tsa bohlokoa joalo ka sesebelisoa sa ho imolla khatello ho matlafatsa polokeho ka ho thibela maemo a khatello e feteletseng le mochini o timang-circuit tap changer bakeng sa ho feto-fetoha ha motlakase ho lumellana le litlhoko tse fapaneng tsa mojaro. Transformer e na le-teminale ea mofuta oa mahlo (eyelet bushings), e tsamaisang likhokahano tse sireletsehileng le tse sebetsang hantle le mehala e holimo. Moetso oa eona- o ntlafalitse tšebeliso ea sebaka hantle ha o ntse o fana ka kabo e sebetsang ea motlakase libakeng tsa mahaeng, literopong kapa liindastering. E entsoe ka katleho le ho phela nako e telele, transformer ena e loketse bakeng sa tšebeliso ea tšebeliso le ea khoebo, e fana ka matla a tsitsitseng tlas'a maemo a sa tšoaneng a sebetsang.

 

 

 

1.2 Tlhaloso ea Setsebi

50 kVA pole mounted transformer specifications type le data sheet

E fetisetsoa ho
Guyana
Selemo
2025
Mofuta
Pole mounted transformer
Standard
IEEE&ANSI C57.12.00
Rated Power
50 kVA
Khafetsa
60HZ
Mokhahlelo
1
Polarity
Subtractive
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
13.8 kV
Motlakase oa bobeli
0.12/0.24 kV
Lintho Tse Hlahang
Koporo
Angular displacement
Ii0
Tšitiso
2%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
0.16 kW
Ho Lahleheloa ke Moroalo
0.512 kW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

 

1.3 Litšoantšo

50 kVA pole mounted transformer diagram to the size and size.

image003

 

 

02 Tlhahiso

2.1 Konokono

Lesela la tšepe la silicon le entsoe ka moea mochining oa CNC ho etsa sebopeho se koetsoeng sa khutlonnetsepa kapa toroidal. Khatello ea maikutlo e laoloa ka hloko nakong ea matsoelintsoeke ho qoba khatello ea maikutlo{1}e bakoang ke ho senyeha ha makenete. Annealing e etsoa sebakeng sa hydrogen at 800 ~ 850℃ho imolla khatello ea kelello ea mochini le ho khutlisetsa matla a matla a khoheli. Lehlakore le leng la mantlha le sehiloeng ka nepo{6}ho lumella ho kenya khola, ka sebaka se sehiloeng se fatše hantle ho fokotsa matla a khoheli. Li-transformer tse kentsoeng-phase pole{9}e le 'ngoe{9} tse nang le maqeba a maqeba li fana ka bokhoni bo holimo, tahlehelo e tlase, le ts'ebetso e khutsitseng, e leng se etsang hore e be tse loketseng marang-rang a sejoale-joale a kabo ea motlakase. Ka tsoelo-pele ea lisebelisoa tse kang tšepe ea amorphous, li-transformer tsa mantlha li tla bapala karolo e kholo le ho feta lits'ebetsong tse bohlale tsa grid nakong e tlang.

wound core transformers

 

2.2 Ho tsubella

copper foil winding

Oli-e qoelisoang ka palo-li-transformer tse koloiloeng hangata li sebelisa{2}}voltage (LV) matsoelintsoeke a foil (copper foil) + -high wire winding (HV) wire winding (copper wire).

• Moea oa LV: Foil ea koporo e alalitsoeng (botenya ba 0.1–2mm) e nang le pampiri e insulatetsang e tsoelipanang, e fana ka sebaka se phahameng, ho pholile hantle, le bokhoni ba ho mamella-sekoere se seholo.

• HV Winnding: -mokhoa oa terata e nang le linamele tse ngata tsa koporo, tse matlafalitsoeng ka pampiri e sireletsang likotopo le likotopo tsa oli bakeng sa matla a matla a dielectric le ho thepha-ho feto-fetoha ha maemo.

Maqhubu a hlophisitsoe hantle (LV ka hare, HV ka ntle) 'me a qoelisoa ka ho feletseng ka har'a oli ea transfoma, ho sebelisoa-mochine oa ho kenya pampiri bakeng sa ho pholile le ho arola motlakase.

 

2.3 Tanka

Tanka e nang le-phase pole{1}} e entsoeng ka litšepe tse batang{2} tse entsoeng ka metjhini e kobehang ka lirolara. Mabota a mathoko a entsoe ka khatiso-e entsoeng ka mapheoana a nang le masenke a sa khaotseng 'me a tšehelitsoe ka mokhoa o nepahetseng ho sebelisoa welding ea TIG. Sekoaelo sa tanka se na le flange-e hokahaneng le 'mele ka oli{7}}li-gaskets tse sa mameleng 'me li boltloe hore li ka koaloa. Li-welds tsohle li etsa tlhahlobo ea ho kenella ha parafine le tlhahlobo ea khatello ea moea ea 0.05MPa. Kalafo e ka holimo e kenyelletsa lehlabathe le lateloang ke{11}}pente ea lijase tse peli (epoxy primer + polyurethane topcoat) bakeng sa tšireletso ea ntle ea kutu.

cylindrical shape transformer tank

 

2.4 Kopano ea ho Qetela

assembled active part

1. Kopano e Phethahalang:Tsamaisa maqhubu a phahameng-le a tlase-motlakase ho ea bohareng, ho netefatsa hore ho tsepamisoa hantle, 'me u sireletse litšehetso tse matsoelintsoeke.

2. Lihokelo tsa Motlakase:Solder kapa crimp lead, hokela mochini o fetolang pompo, phuthela lisebelisoa tsa ho koala, 'me u lokise likhoele sebakeng.

3. Ho Omisa Likhoele:{1}}Beha karolo e sebetsang e kopaneng (konokono le li-winding) ka ontong e omisang, sebelisa mocheso oa vacuum ho tlosa mongobo, 'me u netefatse hore ho hanyetsa ho kenella ho lumellana le litekanyetso.

4. Ho Kenya Tanka:Phahamisa karolo e omisitsoeng e sebetsang 'me u e theole ka hloko ka tanka, ikamahanya le lithapo tsa boemo,' me u tlama liboutu tsa motheo.

5. Kenyelletso ea lisebelisoa:Lihlahla tsa lithaba, valve ea khatello ea khatello le lisebelisoa tse ling, ho tiisa manonyeletso ohle.

6. Ho Tlatsa le ho Tiisa Oli:Vacuum-tlatsa oli e sireletsang ho fihla boemong bo itseng, hlahloba hore na ha e lutle ka mor'a hore u e lokise, 'me u qete ho kopanya.

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Litekanyo tsa ho hanyetsa

/

/

/

Feta

2

Liteko tsa Karolelano

/

Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5%

Letšoao la khokahano: Ii0

-0.05

Feta

3

Liteko tsa polarity

/

Subtractive

Subtractive

Feta

4

Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale

%

kW

I0 :: fana ka boleng bo lekantsoeng

P0: fana ka boleng bo lekantsoeng

mamello ea ho se lahleheloe ke moroalo ke +10%

0.34

0.121

Feta

5

Litahlehelo tsa meroalo, motlakase oa impedance, tahlehelo e felletseng le katleho

/

kW

kW

T:85 likhato

Z%: boleng bo lekantsoeng

Pk: boleng bo lekantsoeng

Pt: boleng bo lekantsoeng

mamello ea impedance ke ± 10%

mamello ea tahlehelo ea boima kaofela ke +6%

2.12

0.514

0.635

99.06

Feta

6

Teko ea Voltage e sebelisitsoeng

/

HV: 34KV 60s

LV: 10kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea ho mamella Voltage e kentsoeng

/

Matla a sebelisoang (KV):

2 Ur

Nako: 48

Hangata (HZ): 150

Ha ho ho putlama ha motlakase oa liteko

Feta

8

Tekanyo ea ho hanyetsa Insulation

GΩ

HV{{0}LV ho ea fatše

LV-HV ho ea fatše

HV&LV ho ea fatše

80.8

63.2

59.7

Feta

9

Leakage Test

/

Khatello e sebelisitsoeng: 20kPA

Nako: 12h

Ha ho na leakage le che

Tšenyo

Feta

10

Teko ea Dielectric ea Oli

kV

E kholo ho feta kapa e lekana le 45

56.96

Feta

 

winding resistance test of transformer
impedance test of transformer

 

 

04 Ho paka le ho Romela

4.1 Ho paka

The single{0}phase pole- transformer mounted e pakiloe ka har'a kreiti ea lehong e tiileng, e sa keneleng mongobo, e sirelelitsoeng ka har'a liboutu le foam ea cushioning. Likotikoti tsa pente tsa spray li phuthetsoe ka filimi ea anti{4}static bubble 'me li behiloe sebakeng se sireletsehileng holim'a kapa ka thōko ho transformer. Kereiti kaofela e phuthetsoe ka lesela le sa keneleng metsi la PVC, le nang le mocheso-moroko o tiisitsoeng le menahano e mennoeng ka tlase bakeng sa ho thibela pula. Matshwao a kantle a kenyeletsa bohareng-ba{9}}matshwao a khoheli, matshwao a thibelang pula, le ditemoso tsa dintho tse ka tukang. Li-slots tsa forklift le likhoele tsa tšepe li tiisa motheo oa lipalangoang tse bolokehileng.

moisture-resistant wooden crate

 

4.2 Ho tsamaisa thepa

commercial invoice of transformer

Tlas'a CIF ho ea Georgetown, Guyana, morekisi o hlophisa lipalangoang tse kenang ka hare ho naha, thepa ea leoatleng le inshorense bakeng sa{0}}li-transformer tse palamisitsoeng, tse tlamehang ho kenngoa ka har'a mabokose a thibelang ho ts'oha le a mongobo{1}(ka li-desiccants ha ho hlokahala). Hobane oli-e tletse, li-transformer li hloka hazardous cargo declaration (MSDS e fanoe). Moreki o sebetsana le tumello ea ho tsoa kantle ho naha le ho fana ka thepa kahare ho naha, a ela hloko bokhoni ba ho phahamisa Port of Georgetown le meeli ea boima ba tsela. Nako ea ho tsamaea ke matsatsi a 35-50; litokomane tsa bohlokoa li kenyelletsa B/L, invoice ea khoebo, lenane la ho paka, pholisi ea inshorense, le COO (mohlala, Foromo ea E).

 

 

05 Sebaka le Kakaretso

Single{{0}phase pole{1}} transformer mounted e hlahella e le tharollo e nepahetseng bakeng sa marangrang a kabo ea motlakase, e fana ka bokhabane bo holimo, moralo o kopaneng, le ho kenya habonolo. Re ikemiseditse ho fana ka dihlahiswa tse tshepehang le tse tshwarellang, tse tshehetswang ke taolo e tiileng ya boleng le boqapi ba thekenoloji ho netefatsa tshebetso e tsitsitseng dibakeng tse fapaneng. Ka ho khetha li-transformer tsa rona, u fumana kholiseho ea ts'ebetso e ikhethang le tšehetso e felletseng ka mor'a{4}}tšehetso ea thekiso, e matlafatsang sistimi ea hau ea motlakase ka polokeho le katleho. Re labalabela ho sebelisana le uena ho aha bokamoso bo botle ba matla!

technological innovation

 

Hot Tags: single phase pole mounted kabo ea transformer, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry