500 kVA Pole Transformer-4.16 / 0.6 kV|Canada 2024

500 kVA Pole Transformer-4.16 / 0.6 kV|Canada 2024

Naha: Canada 2024
Matla: 500kVA
Matla: 4.16/0.6kV
Sebopeho: le IFD
Romela Inquiry

 

 

500 kVA pole transformer

Khetho e tšepahalang, matla a sa sitisoeeng ke letho -{0}}palo e le 'ngoe-e behiloeng ka transformer e matlafatsang mohala o mong le o mong.

 

01 Kakaretso

1.1 Semelo sa Morero

Sena ke 500 kVASingle Phase Pole Mounted transformere ile ea isoa Canada ka 2024. Ke mofuta oa Sethala sa transformer, eo tlase ea eona e nang le sethala sa ho e tšehetsa, Motlakase o ka sehloohong ke 4.16GrdY / 2.4kV le motlakase oa bobeli ke 0.6kV. Matla a maholo ho feta a tloaelehileng. E entsoe ho latela maemo a CSA C2.1. Transformer ena ea 500 kVA Single phase e boima ba 2150 kg e behoa sethaleng. Re e qapile ka theknoloji ea rona e tsoetseng pele le lisebelisoa tsa boleng bo holimo tsa matsoelintsoeke ho fihlela tahlehelo ea mojaro 3 kW. The impedance ke 4% ka mokhoa oa ho pholisa oa ONAN.

Pole transformer ke sesebediswa sa bohlokwa se sebediswang tsamaisong ya motlakase, se sebediswang haholo ho fetola{0}}motlakase wa matla a phahameng ho ba matla a tlase-a matla a motlakase a tlase ho fihlela ditlhoko tsa maemo a fapaneng a motlakase. Hangata e kenngoa lipalong tsa marang-rang a phetisetso ea motlakase le kabo, ka hona lebitso. Molao-motheo oa ts'ebetso oa transformer e kentsoeng ka palo e ka akaretsoa feela joalo ka induction ea motlakase. Ha matla a motlakase a phahameng a phalla ka har'a coil e phahameng ea motlakase, matla a khoheli a hlahisoang a baka phallo ea makenete mokokotlong oa tšepe. Motlakase ona oa makenete o tla kenya tšebetsong matla a electromotive a tlase-motlakase oa motlakase, kahoo o fetole matla a -motlakase o phahameng hore e be matla a tlase{8}}.

Li-transformer tse kentsoeng ka poleitili sebelisoa haholo litsamaisong tsa phetiso le kabo ea matla. Hangata li kentsoe lipalong tsa marang-rang a fetiso le ho ajoa ha motlakase 'me li sebelisoa ho fetola{1}}matla a motlakase a matla a phahameng hore e be matla a tlase-a matla a motlakase a loketseng tšebeliso ea lehae, indasteri le khoebo. Li-transformer tse kentsoeng ka lipalo li ka boela tsa sebelisoa litsing tsa motlakase, likhoebong tsa indasteri le tsa merafo, kaho ea litoropong le libakeng tse ling. Transformer ea cylindrical e nyane ka boholo, e bobebe ka boima ba 'mele ebile e bonolo ho e kenya le ho e hlokomela. Litšenyehelo tse tlase, tse loketseng tsamaiso e nyane le{6}}ea boholo ba phetisetso le kabo ea motlakase. Ts'ebetso ea phetoho ea pole mounted transformer e phahame mme tahlehelo ea matla e ka fokotsoa ka katleho.

Transformer ea rona ea 500 kVA pole e entsoe ka theknoloji e tsoetseng pele 'me e nka thepa ea boleng bo holimo le likarolo tse hlahisang boleng bo tšepahalang le nako e telele ea ts'ebetso.

 

 

1.2 Tlhaloso ea Setsebi

Litlhaloso tsa mofuta oa 500 kVA pole transformer le leqephe la data

E fetisetsoa ho
amerika e boroa
Selemo
2024
Mofuta
Pole mounted transformer
Standard
CSA C2.1
Rated Power
500kVA
Khafetsa
60HZ
Mokhahlelo
1
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
4.16GrdY/2.4 kV
Motlakase oa bobeli
0.6 kV
Lintho Tse Hlahang
Aluminium
Angular displacement
YNyn0
Tšitiso
3%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
0.08KW
Ho Lahleheloa ke Moroalo
1.27KW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

500 kVA sets'oants'o sa setšoantšo sa sefetoleli le boholo.

500 kVA pole transformer diagram 500 kVA pole transformer nameplate

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Thepa e sebelisoang bakeng sa li-rolled core ke lakane e batang haholo-e tšesaane e batang{1}}ea silicon e kolokileng e kenang haholo le khoele e bonolo joalo ka permalloy. Botenya ba letlapa la tšepe ea silicon ke 0.18 ~ 0.30; Botenya ba sekhahla sa Permalloy ke 0.03 ~ 0.10mm. Ho nka mohlala ka li-transformer tse nyane le tse mahareng{8}}e le mohlala, tšebeliso ea rolled core e na le melemo e latelang:

1) Tlas'a maemo a ts'oanang, -tahlehelo ea moroalo oa "rolled core" e fokotsehile ka 7% ho isa ho 10% ha e bapisoa le core core; Ha ho-load current e ka fokotsoang ka 50%~75%.

2) Mokotla o ka etsoa ka masesane a tšesaane haholo a phahameng-a batang a khonang ho kenella{2}}ka lishiti tsa tšepe tsa silicon, tse ka hlahisang li-transformer tse nang le tahlehelo e tlase.

3) Mokotla o pota-potiloeng o na le ts'ebetso e ntle, ha ho na litšila tsa ho kuta, 'me sekhahla sa tšebeliso se batla se le 100%. E ka boela ea sebelisa ts'ebetso ea mochini, ea felisa ts'ebetso ea ho bokella, 'me katleho ea tlhahiso e phahame ka makhetlo a 5 ho isa ho a 10 ho feta ea motheo oa stacking.

4) Mokotla oa coil ka boeona ke o feletseng, ha o hloke ho ts'oaroa ka likarolo tsa tšehetso ea clamping, 'me ha o na lenonyeletso, kahoo tlas'a maemo a tšoanang le a mokokotlo oa mokokotlo, lerata la transformer le ka fokotseha ka 5 ~ 10dB.

5) Coefficient ea tšebetso ea rolled core single-phase transformer e ka ba 1.1; Tse tharo-ka tlase ho 1.15; Bakeng sa li-cores tsa tšepe tsa stacking, coefficient ea ts'ebetso ea matla a manyane e ka bang 1.45, 'me coefficient ea ts'ebetso ea matla a maholo e ka bang 1.15. Ka hona, coil core e loketse haholo li-transformer tse nyane le tse mahareng{7}}.

pole transformer ultra-thin cold-rolled silicon steel sheet core

 

2.2 Ho tsubella

pole transformer electrical coils

Sebopeho se bataletseng sa{0}}mokhoa oa motlakase oa motlakase o tlase se eketsa bokaholimo ba matsoelo, 'me se thusa ho ntlafatsa bokhoni ba ho felisa mocheso. Ka hona, tlas'a maemo a phahameng a mojaro, transformer e sebetsa ka mocheso o tlase, e lelefatsa bophelo ba tšebeletso ea lisebelisoa. Karolo e kholo ea -ea foil foil e tlase e ka fokotsa tahlehelo ea hona joale (I²R loss) le ho fokotsa tahlehelo ea hona joale nakong ea maqhubu, ea ntlafatsa ts'ebetso ea matla le ho ntlafatsa ts'ebetso ea transformer. Ka lebaka la sebopeho sa eona sa polane, matsoelintsoeke a foil a tlase-a matla a tlase a na le khanyetso e phahameng-mokhoa oa ho thibela motlakase 'me o khona ho mamella hona joale hanghang ntle le ho futhumala ho feta tekano kapa ho senyeha, kahoo a ntlafatsa polokeho le botsitso ba transformer. Moralo oa foil matsoelintsoeke ka ka katleho hatella lerata nakong tshebetso, haholo-holo ka boemo ba phahameng hona joale, lerata la taolo tshebetso e totobetse haholoanyane, loketseng bakeng sa dikopo le ditlhoko tsa lerata. Moetso o kopantseng oa -motsamao oa motlakase o tlase le{10}}oa ho tsoelipana ha terata e phahameng o etsa hore matla a khoheli a phahamisoe ka mokhoa o ts'oanang, o fokotsa sekhahla sa ho lutla ha makenete, o ntlafatsa ho sebetsa ha motlakase oa transformer, le ho fokotsa tšitiso ea lisebelisoa tse haufi le motlakase.

 

2.3 Tanka

Tanka ea cylindrical e sebelisa geometry e utloahalang ho qhala khatello ea ka hare le ea ka ntle ka katleho, ho matlafatsa matla a mohaho oa tanka, le ho fokotsa kotsi ea ho senyeha le ho senyeha ho bakoang ke ho fetoha ha mocheso kapa ho fetoha ha mojaro. Moqapi oa li-cylinder o etsa hore oli e phalle ka mokhoa o ts'oanang 'me e ka fokotsa ka katleho mocheso o feteletseng oa sebakeng sa oli. Ka tsela ena, e ka etsa bonnete ba hore oli e sireletsang ea transformer e tsoela pele ho potoloha, e le hore mocheso o aroloe ka mokhoa o ts'oanang le ho senyeha, e leng ho thusang ho ntlafatsa ho tšepahala ka kakaretso ha transformer. Tanka ea mafura ea cylindrical e na le ts'ebetso e ntle ea ho sisinyeha ha lefatše. Tlas'a ketso ea litšisinyeho tsa lefatše kapa matla a mang a ka ntle, sebopeho sa selikalikoe se batla se tsitsitse ts'ebetsong ea mechine, e ka sireletsang likarolo tsa ka hare hantle le ho fokotsa kotsi ea tšenyo ea transformer. Moralo oa tanka ea cylindrical hangata o na le mochini o tiileng oa ho tiisa, o ka thibelang ho tsoa ha oli e sireletsang ka nepo. Ka nako e ts'oanang, e ka boela ea thibela ho kena ha litšila tse ka ntle tse kang moea le mongobo, le ho boloka boleng le bophelo ba tšebeletso ea oli e sireletsang.

cylindrical tank of single pole transformer

 

2.4 Kopano ea ho Qetela

500 kVA pole transformer active part
500 kVA pole transformer finall assembly

 

 

03 Ho etsa liteko

Che.

Ntho ea Teko

Yuniti

Kamohelo

Litekanyetso

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Litekanyo tsa ho hanyetsa

/

/

/

Feta

2

Liteko tsa karo-karolelano

/

Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5%

Letšoao la khokahano: Ii6

0.00

Feta

3

Liteko tsa polarity

/

Keketso

Keketso

Feta

4

Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale

%

I0 :: fana ka boleng bo lekantsoeng

0.22

Feta

kW

P0: fana ka boleng bo lekantsoeng

0.836

/

mamello ea ho se lahleheloe ke moroalo ke ± 15%

/

5

Litahlehelo tsa meroalo, motlakase oa impedance, tahlehelo e felletseng le bokhoni

/

t: likhato tse 85

mamello bakeng sa impedance ke ± 7.5%

mamello ea tahlehelo ea mojaro o felletseng ke ± 8%

/

Feta

%

Z%: boleng bo lekantsoeng

4.05

kW

Pk: boleng bo lekantsoeng

2.887

kW

Pt: boleng bo lekantsoeng

3.723

%

Katleho e seng ka tlase ho 99.26%

99.41

6

Teko ea Voltage e sebelisitsoeng

/

LV: 10kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea ho mamella Voltage e kentsoeng

/

Matla a sebelisoang (kV): 4.8

Ha ho ho putlama ha motlakase oa liteko

Feta

Nako: 60

Hangata (HZ): 120

8

Tekanyo ea ho hanyetsa Insulation

GΩ

LV-HV ho ea fatše:

2.65

Feta

9

Leakage Test

/

Khatello e sebelisitsoeng: 20kPA

Ha ho na leakage le che

Tšenyo

Feta

Nako: 12h

10

Tlhahlobo ea oli

kV

Matla a Dielectric

56.4

Feta

mg/kg

Mongobo

9.5

%

Ntho ea ho senya

0.00206

mg/kg

Furan Analysis

0.03

/

Tlhahlobo ea Khase ea Chromatography

/

 

500 kVA pole transformer testing
500 kVA pole transformer FAT

 

 

04 Ho paka le ho Romela

500 kVA pole transformer packing

500 kVA pole mounted transformer shipping

 

05 Sebaka le Kakaretso

Rea leboha ka thahasello ea hau le ts'ehetso ea hau ho Single{0}Phase pole transformer ea rona! Ka ts'ebetso ea eona e babatsehang, ts'ebetso e tsitsitseng, le boleng bo ka tšeptjoang, sehlahisoa sa rona se fetohile khetho e nepahetseng tšimong ea phetisetso ea matla le kabo. Re tla tsoelapele ho ts'ehetsa melao-motheo ea boqapi ba theknoloji le boleng bo holimo ho u fa litharollo tsa motlakase tse bolokehileng le tse sebetsang hantle. Re labalabela ho sebetsa le uena ho theha bokamoso bo khanyang hammoho! Haeba u na le lipotso kapa litlhoko,ka kopo ikutloe u lokolohile ho ikopanya le rona.

500 kVA pole transformer manufacturer

 

Hot Tags: pole transformer, moetsi, mofani oa thepa, theko, litšenyehelo