1000 KVA Transformer 3 Phase-24 / 0.416 * 0.24 * 0.12 KV|Jamaica 2026
Matla: 1000 kVA
Matla: 24GrdY/13.8-0.416Y/0.24*0.24DkV
Sebopeho: YNyn0/YNd11
Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba tšepahalang ba 1000 kva transformer 3 phase-24/0.416*0.24*0.12 kv|jamaica 2026 Chaena. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

Matla moo o a hlokang teng, botle moo o a bonang teng - ke transfoma e kentsoeng ka pad.
01 Kakaretso
1.1 Tlhaloso ea Morero
1000 kVA phase three phase mounted transformer e ile ea isoa USA ka 2026. Matla a lekantsoeng a transformer ke 1000 kVA e nang le pholiso ea KNAN. Matla a phahameng ke 24GrdY/13.8 kV e nang le ± 2 * 2.5% tapping range (NLTC), motlakase o tlase ke 0.416Y / 0.24 * 0.24D kV, ba thehile lihlopha tse peli tsa li-vector tsa YNyn0 / YNd11.
Litlhophiso tsa Dual Low-Voltage Vector Group bakeng sa Phetoho ea Voltage
Karolo e ikhethang ea projeke ena ke tlhophiso ea sehlopha sa li-voltage tse tlase tsa transformer, e hlophisitsoeng joalo ka YNyn0/YNd11. Khokahanong ea YNyn0, maqhubu a phahameng a motlakase le a tlase ke naleli e hokahaneng le lintlha tse sa nke lehlakore tse hlahisitsoeng, 'me lehlakore la motlakase o tlase le lula le le mothating le lehlakoreng le phahameng la motlakase. Tokisong ea YNd11, moea oa motlakase o tlase o hokahantsoe le delta, e leng se bakang lebelo la 30℃phase lead (kapa 330℃lag) le amanang le lehlakore le phahameng la voltage. Moralo ona oa lihlopha tse peli tsa li-vector o thusa phetoho e bonolo lipakeng tsa litlhophiso tse fapaneng tsa motlakase o tlase, e lumellang moreki ho ikamahanya le litšobotsi tsa motlakase oa motlakase oa motlakase ho fihlela litlhoko tse fapaneng tsa sistimi. Ka likhokahano tsa ka hare tse ka lokisoang bocha le ts'ebeliso ea ntlha e sa nke lehlakore, transformer ha e khone ho fana feela ka maemo a tloaelehileng a 0.416 kV (mohala ho ea ho mola) le 0.24 kV (mohala ho ea ho lehlakore / delta), empa hape le pompo ea 0.12 kV e tlase ea voltage, e fanang ka khetho ea boraro bakeng sa mejaro e khethehileng kapa litlhoko tsa phepelo e thusang. Ts'ebetso ena e matlafalitsoeng e etsa hore li-transformer tsena li tšoanelehe haholo bakeng sa maemo a fapaneng a likhokahano tsa gridi le lits'ebetso tsa motlakase tse ngata.
Tlhokahalo ea Tlhahlobo ea Mofuta: Tekanyo ea Khahlano ea DC Winding
Ka ntle ho liteko tse tloaelehileng tse boletsoeng ho protocol ea tekheniki, morero ona o na le tlhokahalo e khethehileng: tekanyo ea DC Winding Resistance e khethiloe e le teko ea mofuta o tlamang. Teko ena e kenyelletsa ho kenya motlakase o laoloang oa DC ka har'a moea o mong le o mong oa transformer le ho lekanya ho theoha ha motlakase ho bala litekanyetso tsa ho hanyetsa. Teko ea ho hanyetsa mapheo a DC ke sesebelisoa sa bohlokoa sa tlhahlobo se sebelisetsoang ho tseba ho khaotsa ho sebetsa, likhokahano tse fokolang, le li-circuits tse bulehileng ka har'a mapheo, hammoho le ho netefatsa botšepehi ba likhokahano tsohle tsa lipompo. Ka ho etsa teko ena e le teko ea mofuta ho e-na le ho etsa tlhahlobo e tloaelehileng, moreki o fumana kholiseho e phahameng mabapi le ho tsoela pele, boleng ba khokahanyo, le ho nepahala ka kakaretso ho etsoa ha li-transformer tsena{3}e leng tlhokomeliso ea bohlokoa haholo ha ho nahanoa ka-moetso oa lihlopha{5} tsa li-vector{5}le tlhokeho ea ts'ebetso e tšepahalang tlas'a tlhophiso ea likhokahano ka bobeli.
1.2 Tlhaloso ea Setsebi
1000 kVA pad mounted transformer specifications type le data sheet
|
E fetisetsoa ho
Jamaica
|
|
Selemo
2026
|
|
Mofuta
Transformer e kentsoeng ka pampiri
|
|
Standard
IEEE Std C57.12.34-2022
|
|
Rated Power
1000 kVA
|
|
Khafetsa
50HZ
|
|
Mokhahlelo
3
|
|
Fepa
Loop
|
|
Pele
E shoeleng
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
24GrdY/13.8 kV
|
|
Motlakase oa bobeli
0.416Y/0.24 * 0,24 kV
|
|
Lintho Tse Hlahang
Koporo
|
|
Sehlopha sa Vector
YNyn0/YNd11
|
|
Tšitiso
5.75%
|
|
Katleho
99.06%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
1.5 kW
|
|
Ho Lahleheloa ke Moroalo
14.32 kW
|
1.3 Litšoantšo
1000 kVA pad mounted transformer diagram to the size and size.



02 Tlhahiso
2.1 Ho tsubella

Maqhubu a li-transformer a entsoe ka koporo ea 100% ea electrolytic ho netefatsa conductivity e babatsehang, matla a phahameng a potoloho e khutšoanyane, le botsitso ba nako e telele ba mocheso. Motheo ke moralo oa maoto a 5 o hahiloeng ho tsoa ho ho kenella ho hoholo, ho batang, tšepe ea silicon e sekametseng lijo-thollong, e kentsoeng ka nepo ho fokotsa tahlehelo ea hajoale le e lahlehileng. Tokisetso ea maoto a 5 e na le molemo ka ho khetheha bakeng sa tlhophiso ea lihlopha tse peli tsa vector (YNyn0 / YNd11), kaha e leka-lekanya phallo ea phallo tlas'a likhokahano tsa linaleli le delta, kahoo e fokotsa tahlehelo ea mojaro le hona joale.
2.2 LV Conductor Rod (e khuts'oane)
Lehlakore le tlase la motlakase le sebelisa lithupa tsa khohondara tsa tin tse pentiloeng (li-busbar) tse hokelang liteishene tse matsoelintsoeke le lihlahla tsa LV tsa mofuta oa likharafu. Li-rod tsena li entsoe ka boholo ba sebaka sa hajoale (hoo e ka bang{1}} A ho 416 V) tse nang le moeli o lekaneng, 'me li etselitsoe ho mamella khatello e matla ea potoloho le mocheso ntle le ho fetoha. Lithupa li sirelelitsoe ka mokhoa o sireletsehileng 'me li tšehelitsoe ka har'a tanka ho netefatsa hore ho na le khanyetso e tlase, khokahano ea mahala ea tlhokomelo nakong ea bophelo ba transformer.

2.3 Two Position Loadbreak Switch

Li-switches tse tharo tsa FYB 10 tsa mofuta oa bobeli li kentsoe ka phaposing ea HV. Li na le litekanyetso tsa 10 kV, 630 A, tse nang le mocheso oa mocheso oa 20 kA / 2s, matla a ho mamella a 50 kA (tlhōrō), le bophelo ba mochine oa 2000 opereishene. Li-switches li hlophisitsoe bakeng sa lits'ebetso tsa loop feed (tse peli bakeng sa loop in/out, e 'ngoe bakeng sa ts'ireletso ea transformer), e nang le maqhama a notlehang a fihlellehang ho tsoa phaposing e ka pele.
2.4 H0 Bushing (HV Neutral)
Sebaka sa ho se nke lehlakore se phahameng sa motlakase se hlahisoa ka H0 bushing e inehetseng, e leng setaele sa ANSI se nang le mekoti e 'meli ea spade ea 25 kV, 208 A, se nang le sebaka se seholo ho feta kapa se lekanang le 405 mm le BIL ea 125 kV. Seteishene sena se arohaneng sa H0 se lumella sistimi e feto-fetohang - ho se nke lehlakore ho ka theoa ka mokhoa o tiileng, ho theoa metheong, kapa ho tloheloa ntle le motheo ha moea oa HV o hokahantsoe le wye. Ts'ebetsong ea delta, H0 bushing e sebetsa e le sebaka se bonolo sa tlhahlobo bakeng sa tlhahlobo ea ho kenella.
Ho feta moo, ho fanoe ka lithapo tse peli tse sa pentiloeng tsa tšepe e sa hloekang (e le 'ngoe ka phaposing e' ngoe le e 'ngoe) bakeng sa tanka e tšepahalang le tsamaiso ea sistimi.

2.5 Kopano ea ho Qetela

Kopano e latela moralo o tiileng oa boleng: core stacking, coil winding, lead connection, le insulation taping li etsoa tlas'a maemo a laoloang. Karolo e sebetsang ka ho feletseng e kena ts'ebetsong ea ho omisa le ho tlatsa oli ho tlosa mongobo ho tloha ho sekontiri se tiileng, ho netefatsa hore tsamaiso ea dielectric e omeletseng le e tsitsitseng pele ho koaloa ha tanka ea ho qetela.
Tanka e entsoe ka mofuta o tiisitsoeng o nang le sekoaelo se bolted, se entsoeng ka tšepe e bonolo. Sebaka se koaletsoeng se koahetsoe ka Munsell 7GY3.29 / 1.5 finish, se finyella litlhoko tsa IEEE C57.12.28 bakeng sa ho hanyetsa kutu libakeng tse lebōpong la leoatle. Lits'oants'o tse phahamisang le liphahlo tsa jacking li fanoa bakeng sa ho ts'oaroa ka mokhoa o sireletsehileng.
03 Teko
Liteko tsohle li etsoa ho latela IEEE C57.12.34 2022 le IEEE C57.12.90.
Liteko tsa ka mehla (tse etsoang yuniting e 'ngoe le e 'ngoe):
• Fetosa karo-karolelano le phalliso ea mokhahlelo (YNyn0 le YNd11 li netefalitsoe)
• Ha ho tahlehelo ea mojaro le hona joale e thabisang
• Ho lahleheloa ke moroalo le motlakase oa impedance
• Matla a mahlahahlaha a sebelisitsoeng (HV: 40 kV; LV: 10 kV)
• Matla a matla a ho mamella
• Teko ea ho lutla ha tanka (50 kPa bakeng sa lihora tse 12)
• Matla a dielectric a oli ( A maholo ho feta kapa a lekana le 45 kV)
• DC insulation resistance and polarization index
Liteko tsa mofuta - tlhokahalo e khethehileng bakeng sa morero ona ke hore tekanyo ea DC Winding Resistance e khethiloe e le teko ea mofuta o tlamang, eseng feela tlhahlobo e tloaelehileng. Teko ena e kenya motlakase oa DC o laoloang sebakeng se seng le se seng 'me e lekanya ho theoha ha motlakase ho bala litekanyetso tsa ho hanyetsa. Ke tlhahlobo ea bohlokoa bakeng sa ho bona likhoele tse robehileng, likhokahano tse fokolang tsa interturn, kapa li-joints tsa theipi tse hlephileng. Ka ho e etsa e le tlhahlobo ea mofuta, re fana ka boemo bo phahameng ba tiisetso mabapi le ho tsoela pele le botšepehi ba khokahano - ho bohlokoa haholo ho latela litlhophiso tse peli tse fapaneng tsa lihlopha tsa vector.
Ho tsoa tlalehong e phethiloeng ea teko (Seriale No{0}}), litekanyetso tse lekantsoeng:
• Ha ho tahlehelo ea mojaro: 1.1445 kW
• Ho lahleheloa ke mojaro (85℃): 12.037 kW
• Tšitiso: 5.74%
• Ho sebetsa hantle: 99.23% - kaofela ho feta lipalo tse tiisitsoeng.


04 Matšoenyeho a Bareki
Lintlha tse 'maloa tsa bohlokoa li rarollotsoe ho fihlela litlhoko tse ikhethileng tsa moreki oa Canada:
• Ts'ebetso ea sehlopha sa li-vector tse peli (YNyn0/YNd11): Lihokelo tsa ka hare li entsoe e le hore matsoelintsoeke a LV a ka hlophisoa bocha ho tloha naleling ho ea ho leriba. Ho naleli, mohato oa ho se nke lehlakore ke 240 V le mola ho ea ho 416 V; karolong ea delta, khoele ea ho ea mola e sala e le 416 V, ha theipi e bohareng e fana ka 120 0 120 V (ke hore, 0.12 kV) bakeng sa mejaro e thusang. Phetoho e bonolo, e sebelisa lipoleiti tse fanoeng.
• Tlhokahalo ea tlhahlobo ea mofuta: Moreki o ile a kopa DC winding resistance e le teko ea mofuta - sena se ba fa bopaki bo ngotsoeng ba ho lumellana ha tlhahiso le boleng ba khokahanyo ho pholletsa le litlhophiso tse peli tse matsoelintsoeke.
• Tikoloho ea lebopo la tropike: Li-transformer li entsoe ka ts'ireletso e matlafalitsoeng ea kutu (sistimi ea pente e teteaneng, hardware ea tšepe e sa hloekang) le maemo a phahameng a BIL ho mamella ho otla ha lehalima khafetsa, mongobo o phahameng, le moea oa letsoai, ho latela litlhaloso tsa Jamaican (JPSCo 6950 S 04).

05 Ho paka le ho romela
5.1 Ho paka
Transformer e 'ngoe le e' ngoe e pakiloe ka bonngoe ka har'a kreiti e boima ea lepolanka, e etselitsoeng ho ts'oaroa ha fereko le lipalangoang tsa leoatle. Likarolo tse utloang bohloko (lihlahla tsa porcelain, valve ea ho fokotsa khatello, tekanyo ea boemo) le tsona li kenngoe ka thepa e monyang maikutlo. Kreiti e tšoailoe ka lileibole tsa "UP" le "FRAGILE". Boemo ba oli bo hlokomeloa ka 100 150 limilimithara ka tlase ho tanka ho lumella katoloso ea mocheso nakong ea leeto.

5.2 Ho tsamaisa thepa

Thomello e etsoa e le yuniti e felletseng (e bokaneng ka botlalo, e tletse oli). Pele ho romelloa, ho hlokahala tumello e ngotsoeng e tsoang ho moreki, 'me litlaleho tsa tlhahlobo tse netefalitsoeng li tlameha ho romelloa le ho amoheloa.
Li-transformer li romelloa CIF Kingston, Jamaica (kapa ho latela boema-kepe boo ho lumellanoeng ka bona). Lintlha tsa ho phahamisa le ho tiisa li tšoailoe ka ho hlaka. Sephutheloana sa lepolanka se lumellana le litekanyetso tsa ISPM 15 tsa phytosanitary bakeng sa thomello ea machaba. Ho thothomela ha transit le ho ts'oha ho 'nile ha nahanoa ka moralo oa litšehetso tsa ka hare.
05 Sebaka le kakaretso
Li-transformer tse kentsoeng tsa SCOTECH li tšeptjoa bakeng sa merero ea matla a litoropo, ea khoebo, ea indasteri le e nchafatsoang. Re amohela lipotso tsa hau le litaelo tsa tloaelo - sehlopha sa rona sa litsebi se ikemiselitse ho u thusa ho tloha khethong ho fihlela ka mor'a tšehetso ea thekiso. Ikopanye le rona kajeno - lumella SCOTECH ho matlafatsa katleho ea hau.

Hot Tags: 1000 kva transformer 3 phase-24 / 0.416 * 0.24 * 0.12 kv|jamaica 2026, Chaena 1000 kva transformer 3 phase-24 / 0.416 * 0.24 * 0.12 kv|jamaica 2026 baetsi, barekisi, feme
You Might Also Like
1000 kVA Oli e Tlatsang Pad Mounted Transformer-13.8...