2250 kVA Pad Mounted Transformer-12.47/0.6 kV|USA 2025
Matla: 2250kVA
Matla: 12.47GrdY/7.2-0.6Y/0.347kV
Tšobotsi: Ka oli ea FR3

2250 kVA pad mounted transformer-e etselitsoeng mapolasi a letsatsi, e hahelletsoeng bakeng sa polokeho, ts'ebetso e ntle, le bokamoso bo botle ba matla.
01 Kakaretso
1.1 Semelo sa Morero
Ho ts'ehetsa katoloso e ntseng e hola ea lisebelisoa tsa matla a letsatsi 'marakeng oa US, re rometse 2250 kVA -phase three-transformer e kentsoeng ka mokhoa o khethehileng bakeng sa ts'ebeliso-scale photovoltaic (PV) ts'ebeliso. E entsoe ka-mohaho o matla oa maoto a mahlano 'me o shoele-ka pele, lupu-peakanyo ea phepelo, karolo ena e netefatsa polokeho, ts'epahalo, le ho tenyetseha ha sistimi tikolohong ea matla a ka nchafalitsoeng.
Sena2250 kva pad mounted transformere sebetsa ka motlakase o ka sehloohong oa 12.47 GrdY / 7.2 kV le motlakase oa bobeli oa 0.6Y / 0.347 kV, e leng se etsang hore e be se loketseng bakeng sa ho hokahanya le li-inverters tsa letsatsi le marang-rang a kabo ea tlaase. Sehlopha sa li-vector YNyn0 se etsa hore ho be le motheo o sebetsang hantle 'me se nolofalletsa likhokahano tse tlase-mohato oa boraro{7}}mapolasing a letsatsi. Ka aluminium windings, yuniti e fana ka tekanyo pakeng tsa ts'ebetso le ts'ebetso ea litšenyehelo.
Built with FR3 natural ester fluid, the transformer achieves a high level of environmental sustainability and fire safety, thanks to its high flash point (>300℃) le biodegradability. Moralo oa KNAN (moea oa tlhaho{2}}o pholileng) o fokotsa ho rarahana ha tšebetso le litlhoko tsa tlhokomelo ha o ntse o netefatsa hore mocheso o sebetsa hantle haholo.
E fanoe ka kemiso, transformer ena e kenya letsoho ka ho toba katolosong ea litšebeletso tsa motlakase tsa letsatsi, ho tšehetsa lipakane tse pharaletseng tsa naha tsa decarbonization le grid modernization. E bonts'a bokhoni ba rona ba ho etsa lisebelisuoa tse phahameng- tse sebetsang, tse sebetsang- bakeng sa litlhoko tse ntseng li tsoela pele tsa matla a ka nchafatsoang.
1.2 Tlhaloso ea Setsebi
2250 kVA pad mounted transformer specifications and data sheet
|
E fetisetsoa ho
Amerika
|
|
Selemo
2025
|
|
Mofuta
Transformer ea mekhahlelo e meraro
|
|
Standard
IEEE Std C57.12.34-2022
|
|
Rated Power
2250 kVA
|
|
Khafetsa
60 HZ
|
|
Fepa
Loop
|
|
Pele
E shoeleng
|
|
Mokhahlelo
Boraro
|
|
Mofuta oa ho Pholisa
KNAN
|
|
Mokelikeli o thibelang metsi
Oli ea FR3
|
|
Voltage ea mantlha
12.47 kV
|
|
Motlakase oa bobeli
0.6 Kv
|
|
Sehlopha sa Vector
YNyn0
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
5.75%
|
|
Katleho
99.52%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%
|
|
Ha ho Tahlehelo ea Mojaro
2.4 kW
|
|
Ho Lahleheloa ke Moroalo
15.79 kW
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
2250 kVA pad mounted transformer litekanyo le lintlha tsa boima ba 'mele
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa
Meetso e mehlano-e etsa bonnete ba ho sebetsana le zero{1}}ka tatellano ea tatellano le maemo a sa leka-lekanang a ho laela, a atileng litsing tsa matla a ajoang. Loop ya teng-feed and dead-kaho ea ka pele e tsamaisana le maemo a tshireletso a US mme e nolofalletsa ho kenya tšebetsong mahlaseli a letsatsi, liteishene tse nyane, le{7}}libaka tseo batho ba fihlang ho tsona.

2.2 Ho tsubella

Transformer ena ea 2250 kva pad mounted e na le-voltage e phahameng e nang le moetso oa terata-ea maqeba, e fana ka palo e phahameng ea ho reteleha ho netefatsa hore motlakase o tsamaisoa ka mokhoa o ts'oanang le ho sebetsa hantle haholo. Maqhubu a {{4}voltage a tlase a sebelisa sebopeho sa foil ho sebetsana le maqhubu a phahameng hantle ha a ntse a fokotsa tahlehelo. Tokiso ea sehlopha sa YNyn0 ea vector e ts'ehetsa ho se nke lehlakore mahlakoreng a mabeli a phahameng le a tlase, ho matlafatsa polokeho le botsitso ba sistimi{7}litlhoko tsa bohlokoa bakeng sa lits'ebetso tsa photovoltaic. Ho feta moo, lintlha tse peli tse tlase{9}}li lumella likhokahano tse feto-fetohang ho litlhophiso tse fapaneng tsa mojaro, ho ntlafatsa ts'epahalo ea sistimi le ho ikamahanya le maemo mererong ea matla a letsatsi.
2.3 Tanka
Transformer e kentsoeng ea 2250 kva pad e kenyelletsa tanka ea oli e tiisitsoeng e entsoeng ka tšepe e bonolo, e koahetsoeng ka phofo e tšoeu e matla (RAL 9003) ho matlafatsa ho hanyetsa kutu. Sekoahelo se entsoeng ka bolt se tiisa tiiso e sireletsehileng, e sireletsang oli e sireletsang ka hare.
Transformer e na le li-radiator tse entsoeng ka makotikoti a kopantsoeng ka mahlakoreng ka bobeli le ka morao ea tanka ea oli, e sebetsang e le lintho tse pholisang ka ho eketsa sebaka sa kantle sa moea oa tlhaho. Li-radiator tsena li tšehelitsoe ka mokhoa o sireletsehileng 'me li tiisitsoe-li hokahantsoe le tanka e kholo ho netefatsa hore ho lutla-ho sebetsa mahala tlas'a libaesekele tse futhumetseng. Ho tjheseletsa ka nepo sehokelong ho netefatsa matla a mochini le oli{4}}e tiileng, ha e ntse e lumella katoloso ea mocheso ntle le ho senya botsitso ba sebopeho kapa ts'ebetso ea mohatsela.

2.4 Kopano ea ho Qetela

Boemong ba ho qetela ba ho kopanya, sefetoleli sena sa 2250 kVA pad-motlakase o etselitsoeng lisebelisoa tsa matla a letsatsi se na le lihlahla tse tšeletseng tsa 200A tse arohanngoang le li-HV, li-neutral (H0) bushing, le {4}cast spade{5}}mofuta oa LV bushings tse nang le likoti tse 12.
Ts'ireletso ea transformer e kenyelletsa li-fuse tse tharo tsa bayonet, -limiting fuses (CLF) tsa hajoale-mofuta oa litebelisoa tsa lehalima tse nang le metal oxide varistors tse tsamaellanang le litekanyetso tsa IEEE 386, tse netefatsang ts'ebetso e matla le ts'ireletso ea liphoso libakeng tse shoeleng{3}}ka pele.
Li-pads tsa fatše tse kentsoeng mahlakoreng ka bobeli a HV le LV li ntlafatsa polokeho ea ts'ebetso le ts'epahalo ea ts'ebetso.
03 Ho etsa liteko
Teko e Tloaelehileng le Tekanyetso ea Teko
1. Litekanyo tsa Resistance: Ho latela IEEE C57.12.90-2021 Clause 5
2. Liteko tsa Karolelano: Ho latela IEEE C57.12.90-2021 Clause 7
3. Teko ea kamano ea Mokhahlelo-: Ho latela IEEE C57.12.90-2021 Clause 6
4. Ha ho Tahlehelo ea Moroalo ebile ha ho Moroalo Hona Joale: Ho latela IEEE C57.12.90-2021 Clause 8
5. Litahlehelo tsa Meroalo, Matla a Matla a Impedans le katleho: Ho latela IEEE C57.12.90-2021 Clause 9
6. Applied Voltage Test: Ho latela IEEE C57.12.90-2021 Clause 10.6
7. Induced Voltage Withstand Test: Ho latela IEEE C57.12.90-2021 Clause 10.5.1
8. Tekanyo ea ho hanyetsa Insulation
9. Teko ea ho Lutla ka Khatello Bakeng sa Li-transformers tse Immersed Liquid: Teko e lutlang ho 20KPa e tla etsoa bakeng sa 12h ntle le ho lutla. Ha ho deformation e sa feleng.
Liphetho tsa liteko
|
Che. |
Ntho ea Teko |
Yuniti |
Melao ea ho Amohela |
Litekanyetso Tse Lekanyelitsoeng |
Qetello |
|
1 |
Litekanyo tsa ho hanyetsa |
% |
Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane |
1.97 |
Feta |
|
2 |
Liteko tsa karo-karolelano |
% |
Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5% Letšoao la khokahano: YNyn0 |
-0.14% ~ 0.11% |
Feta |
|
3 |
diteko- tsa dikamano |
/ |
YNyn0 |
YNyn0 |
Feta |
|
4 |
Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale |
/ |
I0:: fana ka boleng bo lekantsoeng |
0.22% |
Feta |
|
P0: fana ka boleng bo lekantsoeng(t:20 degree) |
2.200kW |
||||
|
Mamello ea ho se lahleheloe ke moroalo ke +10% |
/ |
||||
|
5 |
Litahlehelo tsa tahlehelo ea matla a motlakase le katleho |
/ |
T:85 likhato Mamello ea impedance ke ± 7.5% Mamello ea tahlehelo ea boima kaofela ke +6% |
/ |
Feta |
|
Z%: boleng bo lekantsoeng |
5.88% |
||||
|
Pk: boleng bo lekantsoeng |
14.325kW |
||||
|
Pt: boleng bo lekantsoeng |
16.525 kW |
||||
|
Katleho e seng ka tlase ho 99.52% |
99.52% |
||||
|
6 |
Teko ea Voltage e sebelisitsoeng |
kV |
HV/: 34kV 60s LV/: 10kV 60s |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
7 |
Teko ea ho mamella Voltage e kentsoeng |
kV |
Matla a sebelisoang (KV): 2Ur |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
Nako:48 |
|||||
|
Hangata (HZ): 150 |
|||||
|
8 |
Leakage Test |
kPa |
Khatello e sebelisitsoeng: 20kPA |
Ha ho na leakage le che Tšenyo |
Feta |
|
Nako:12h |
|||||
|
9 |
Tekanyo ea ho hanyetsa Insulation |
GΩ |
HV{{0}LV ho ea fatše : |
2.01 |
/ |
|
LV-HV ho ea fatše: |
1.66 |
||||
|
HV&LV ho ea fatše |
1.03 |




04 Ho paka le ho Romela


05 Sebaka le Kakaretso
Transformer ena ea 2250 kVA-phase three phase-e hlophisitsoe ka mokhoa o khethehileng bakeng sa ts'ebeliso-mesebetsi ea sekala sa solar PV 'marakeng oa US. E ts'ehetsa kabo ea motlakase e tsitsitseng le e bolokehileng ka likarolo tse fihlelang litekanyetso tsa polokeho ea US, e netefatsang kopano e tšepahalang mapolasing a letsatsi le lits'ebetso tsa matla a tsosolositsoeng.
E na le insulation e tsoetseng pele le e pholileng, e fana ka ts'ebetso e sebetsang hantle,{0}}e bonolo bakeng sa lisebelisoa tse hloekileng tsa matla. Likarolo tsa ts'ireletso tse matla li netefatsa ts'ebetso e bolokehileng libakeng tse thata tsa kantle.
Li-transformer tsa rona li entsoe ho fihlela litlhoko tse ntseng li hola tsa lekala la matla a tsosolositsoeng a US. Ikopanye le rona bakeng sa litharollo tse lokiselitsoeng ho matlafatsa merero ea hau ea matla a letsatsi.

Hot Tags: 2250 kva pad mounted transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
150 kVA Mokelikeli o Tlatsitse Transformer-13.2/0.48...
500 kVA Dead Pad Mounted Mounted Transformer-24.94/0...
500kVA Pad Mount Transformer-14.4/0.208 kV|Sebelisa ...
500 kVA Pad Mount Transformer-13.8/0.48 kV|USA 2025
2000 kVA Pad Mounted Transformer-24/0.48 kV|USA 2024
1500 kVA Ansi C57 12.34 Transformer-23/0.44 kV|Salva...
Romela Inquiry