300 kVA Pad Mounted Transformer-12/0.208 kV|Jamaica 2025

300 kVA Pad Mounted Transformer-12/0.208 kV|Jamaica 2025

Naha: Jamaica 2025
Matla: 300 kVA
Matla: 12GrdY/6.928-0.208/0.12 kV
Tšobotsi: e nang le sets'oants'o sa mofuta oa setsoe
Romela Inquiry

 

 

300 kva pad mounted transformer

Motlakase o sa khaotseng, o sa sitisoe-Mohaho{1}}o kentsoeng li-transformer tsa mekhahlelo e meraro, tse netefatsang hore li sebetsa letsatsi le letsatsi.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

300 kVA phase three phase mounted transformer e ile ea isoa Jamaica ka 2025. Matla a lekantsoeng a transformer ke 300 kVA e nang le pholiso ea ONAN. Motlakase oa mantlha ke 12GrdY/6.928 kV e nang le ± 2 * 2.5% tapping range (NLTC), motlakase oa bobeli ke 0.208 / 0.12 kV, ba thehile sehlopha sa vector sa YNyn0.

Moreki oa rona, e leng setsi sa masepala se sebeletsang sebaka se ntseng se hola ka potlako ho la US Pacific Northwest, se reka 300 kVA, 12kV 12kV three-phase three{{5} transformer e behoang bakeng sa boikitlaetso ba bohlokoa ba ho ntlafatsa grid. Yuniti ena e tla kengoa bohareng ba setereke se secha sa khoebo, se tla sebetsa e le setsi sa mantlha sa kabo ea motlakase bakeng sa motswako oa litsi tsa mabenkele, liofisi, le{7}}meaho ea malapa a mangata.

Morero ona o hlahisa liphephetso tse tharo tsa bohlokoa:

Ho Mamelleha ho Likhatello Tse Khethehileng tsa Tikoloho:Sebaka sena se na le ts'ebetso e kholo ea litšisinyeho tsa lefatše le lehloa le leholo mariha. Transformer e tlameha ho etsoa enjene ea ho mamella matla a tšisinyeho ea lefatše ea Zone 4 le lehloa le fihlang ho 150 PSF.

Tumellano e sa Sekisetseng:Ho lumellana ka botlalo le litekanyetso tsa IEEE C57.12.20 le C57.12.90 ke tlamo. Moralo o tlameha ho kopana le lintlha tsa ts'ebeliso ea lehae bakeng sa mefokolo ea hona joale le meeli ea hona joale ea inrush ho netefatsa tšebelisano ea grid.

Khokahano ea Aesthetic sebakeng sa Urban Landscape:E lutse sebakeng sa batho ba tsamaeang ka maoto-karolo ea transformer e hloka-profaele e tlase, e entsoeng ka moralo o hlophisitsoeng o lumellanang le mebala le melumo{2}}e fokotsang molumo ho fokotsa matla a pono le molumo.

 

 

 

1.2 Tlhaloso ea Setsebi

300 kVA pad mounted transformer specifications type le data sheet

E fetisetsoa ho
Jamaica
Selemo
2025
Mofuta
Transformer e kentsoeng ka pampiri
Standard
IEEE StdC57.12.34-2022
Rated Power
300 kVA
Khafetsa
50HZ
Mokhahlelo
3
Fepa
Loop
Pele
E shoeleng
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
12GrdY/6.928 kV
Motlakase oa bobeli
0.208/0.12 kV
Lintho Tse Hlahang
Koporo
Angular displacement
YNyn0
Tšitiso
5.5%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
0.53kW
Ho Lahleheloa ke Moroalo
4.755 kW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

 

1.3 Litšoantšo

300 kVA pad mounted transformer diagram to the size and size.

300 kva pad mounted transformer diagram 300 kva pad mounted transformer nameplate

 

 

02 Tlhahiso

2.1 Konokono

 

Transformer ena-mohato oa bohlano-e hahiloe ka lishiti tsa tšepe tsa silicon tse pakiloeng hantle, e sa fokotseng-tahlehelo ea mojaro ka ho fihla ho 15% 'me e sebetsa hantle ho feta 99%. Motsoako oa eona o leka-lekaneng oa makenete o fokotsa hysteresis le tahlehelo ea hona joale ea eddy ka 10-20%, ha lerata la ts'ebetso le theoleloa ka 5-10 dB (A). Moralo o matla o ntlafatsa matla a mochini le ts'ebetso ea mocheso, ho boloka mocheso o ka tlase ho 65 K tlasa mojaro o felletseng bakeng sa bophelo bo atolositsoeng ba ts'ebeletso.

excellent magnetic core transformer

 

2.2 Ho tsubella

thick foil conductors

Transformer ena e sebelisa hybrid winding configuration, e kopantseng sebaka se phahameng sa-voltage (HV) le matsoelintsoeke a tlase{1}}le foil (LV) foil. HV winding e sebelisa terata e sirelelitsoeng hantle, e eketsang matla a ho koala le ho fokotsa matla a sebaka sa motlakase ka hoo e ka bang 15–20%, e netefatsa hore e sebetsa ka botšepehi tlas'a{5}maemo a matla a motlakase. Ho sa le joalo, matsoelintsoeke a LV a sebelisa foil e teteaneng, e ntlafatsang kabo ea hajoale le ho eketsa{7}}sekoere se mamellang matla a ho fihla ho 25% ha ho bapisoa le mapheo a tloaelehileng a terata. Moralo ona o boetse o ntlafatsa phallo ea mocheso, o fokotsa ho phahama ha mocheso oa hotspot ka likhato tse 10-15 le ho nolofatsa mekhoa ea ho kenya le ho e lokisa.

 

2.3 Tanka

Tanka ea oli e entsoe ka tšepe e phahameng-ho matlafatsa matla a eona a ho bola le matla a ho jara-matla a eona. Ts'ebetso e qala ka ho hatakela ka mokhoa o nepahetseng ho etsa lipoleiti tsa tšepe, ho lateloa ke ho sebelisa CO2 shielding welding ho hokahanya likarolo ka mokhoa o sireletsehileng, ho thibela mapetsong kapa deformation. Ka mor'a ho tjheseletsa, ho sebelisoa litlhare tsa ho tiisa ho thibela ho lutla ha oli ea transfoma, 'me ho sebelisoa litlolo tse thibelang mafome ho thibela kutu. Qetellong, tanka ea oli e etsoa tlhahlobo e matla ea boleng, ho kenyeletsoa tlhahlobo ea khatello le ho lemoha ho lutla, ho netefatsa polokeho le ts'ebetso ea eona.

transformer oil leakage

 

2.4 Kopano ea ho Qetela

electrical wiring

Ho kengoa sebakeng sa-ho hlophisoa ka mehato ea bohlokoa: ka mor'a hore karolo e sebetsang e kenngoe ka tankeng ea oli, litebelisoa tsa motlakase tse phahameng le tse tlase li hokeloa ho sebelisoa lithulusi tsa torque tse lekantsoeng ho etsa bonnete ba hore li-terminal integrity li nepahetse. Lisebelisoa tsa bohlokoa-ho kenyeletsoa li- fuse tsa bayonet, thermometer, gauge ea boemo ba oli, le bushings-e ntan'o kengoa ho lumella tsamaiso le ts'ireletso. Kamora ho kenya lithapo tsa motlakase ho latela moralo, ts'ebetso e phethela ka ho tlatsa vacuum ea oli e sireletsang, ho fihlela phoka e ka tlase ho -40℃ho boloka insurance e nepahetseng le ho sebetsa ha nako e telele ho pholile.

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Litekanyo tsa ho hanyetsa

%

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane Ka tlase kapa ho lekana le 5%

1.64

Feta

2

Liteko tsa Karolelano

%

Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5%

Letšoao la khokahano: YNyn0

-0.03%~0.06%

Feta

3

Liteko tsa likamano tsa mohato-

/

YNyn0

YNyn0

Feta

4

Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale

%

kW

Ka likhato tse 20

I0 :: fana ka boleng bo lekantsoeng

P0: fana ka boleng bo lekantsoeng

0.87%

0.463

Feta

5

Litahlehelo tsa tahlehelo ea matla a motlakase le katleho

%

kW

kW

T:85 likhato

Z%: boleng bo lekantsoeng

Pk: boleng bo lekantsoeng

Pt: boleng bo lekantsoeng

mamello bakeng sa impedance ke ± 7.5%

Katleho e seng ka tlase ho 98.94%

5.50%

4.662

5.125

99.00%

Feta

6

Teko ea Voltage e sebelisitsoeng

kV

HV: 40kV 60s

LV: 10kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea ho mamella Voltage e kentsoeng

kV

Matla a sebelisoang (KV):

2 Ur

Nako:40

Hangata (HZ): 150

Ha ho ho putlama ha motlakase oa liteko

Feta

8

Leakage Test

kPa

Khatello e sebelisitsoeng: 20kPA

Nako: 12h

Ha ho na leakage le che

Tšenyo

Feta

9

Tekanyo ea ho hanyetsa Insulation

HV{{0}LV ho ea fatše :

LV-HV ho ea fatše:

HV&LV ho ea fatše:

26.9

28.7

22.8

Feta

10

Teko ea Dielectric ea Oli

kV

E kholo ho feta kapa e lekana le 45

57.56

Feta

 

300kva transformer Applied Voltage Test
300kva transformer Ratio Tests

 

 

04 Ho paka le ho Romela

4.1 Ho paka

Transformer e sirelelitsoe ka har'a foreimi ea tšepe e matlafalitsoeng 'me e sirelelitsoe ke liphanele tsa tšepe tse teteaneng tsa 0.8mm. Likaroloana tsa bohlokoa ha li sebetse hantle ka ho sebelisa masakata a tloaelo a phahameng-ea polyethylene (HDPE), a fokotsang ho sisinyeha{3}}kotsi ea tšenyo e bakiloeng ke ho feta 30%. Sesebelisoa se tla koaheloa ka filimi ea vacuum-ka 0.12mm e thibelang{8}}filimi ea condensation ebe e kenngoa ka har'a kreiti ea lepolanka e thibelang boemo ba leholimo, e sireletsang IP55 bakeng sa polokelo ea ka ntle ea likhoeli tse 12. Seseteme ena ea ho paka e bonts'itse tšenyo ea 99.8%{{13}reite ea mahala nakong ea tlhahlobo ea ISTA 3A e tloaelehileng.

12kv transformer package

 

4.2 Ho tsamaisa thepa

Kingston port

E etselitsoe ho tsamaisa thepa ka leoatleng, -mohato oa boraro-sefetoleli se koloiloeng se sirelelitsoe ka har'a setifikeiti se sebelisa-li-point steel lashing tse 3{9}}li-inch tse 3{9}. Yuniti e behiloe leihlo ke sehatisi sa ts'isinyeho ea dijithale, ho netefatsa hore litlamorao tsohle tse otlolohileng le tse tšekaletseng li lula li le ka tlase ho 2.5g le 1.2g ka ho latellana nakong eohle ea leeto. Mokhoa ona o fihletse sekhahla sa 99.9% se se nang tšenyo litseleng tse fetang 8,000 nautical miles, se tiisitsoeng ke tlhahlobo ea ISTA 3E ea ho etsisa.

 

 

05 Sebaka le Kakaretso

Ha ts'epahalo e ke ke ea senyeha,{0}}phase ena ea mekhahlelo e meraro-e kentsoeng ka transformer e fana ka ts'ebetso e netefalitsoeng tlas'a maemo a boima. E etselitsoe ho feta maemo a indasteri 'me e etselitsoe ts'ebetso ea nako e telele libakeng tse senyang,{3}}moroalo o phahameng, e feta lisebelisoa{4}ke sebaka se tsitsitseng ho grid ea hau e ntseng e hola.

Na u itokiselitse ho matlafatsa sechaba sa heno ka kholiseho?
Ikopanye le sehlopha sa rona sa boenjiniere kajeno ho buisana ka lintlha tsa projeke ea hau kapa u kope lintlha tse qaqileng tsa sehlahisoa.

technical inquiries

 