75 kVA 3 Phase Distribution Transformer-13.8/0.208 kV|Canada 2024
Matla: 75kVA
Matla: 13.8/0.208kV
Sebopeho: e nang le switch ea khefu ea mojaro

Ho tloha ka matla ho isa nakong e tlang, Three{{0}Phase Pad{1}Mounted Transformer e netefatsa bokgabane motsotsoana o mong le o mong!
01 Kakaretso
1.1 Semelo sa Morero
Transformer ena ea 75 kVA Pad mounted e ile ea isoa Canada ka 2024, matla a lekantsoeng a transformer ke 75kVA, motlakase oa mantlha le motlakase oa bobeli oa transformer ke 13.8 / 0.208kV. Mofuta ona oa transformer e kentsoeng pampiring e hlahisoang ke khamphani ea rona e sebelisa fuse e habeli e felletseng-mokhoa oa ts'ireletso ea mefuta-futa, o fokotsang litšenyehelo tsa ts'ebetso haholo. Ho feta moo, tahlehelo ea li-transformer e ka tlase ho maemo a naha, tlhokomelo ea lilemo tse 20{{9}mahala, moruo le tikoloho.
Re etsa bonnete ba hore karolo e 'ngoe le e 'ngoe ea rona e tlisitsoeng e entse tlhahlobo e matla ea ho amoheloa. Re fana ka-tšebeletso e le 'ngoe ho tloha ho boeletsi, ho qotsa, ho etsa thepa, ho kenya tšebetsong, ho fana ka lithupelo ho isa litšebeletsong tsa ka mor'a thekiso, lihlahisoa tsa rona li se li sebetsa literekeng tse fetang 50 lefatšeng. Re ikemiselitse ho ba morekisi ea tšepahalang ka ho fetisisa hammoho le molekane oa hau ea hloahloa khoebong!
1.2 Tlhaloso ea Setsebi
75 KVA pad mounted transformer specifications and data sheet
|
E fetisetsoa ho
Canada
|
|
Selemo
2024
|
|
Mohlala
75KVA-13.8GrdY/7.97-0.208GrdY/0.12KV
|
|
Mofuta
Transformer e kentsoeng ka pampiri
|
|
Standard
IEEE C57.12.34
|
|
Rated Power
75KVA
|
|
Khafetsa
60HZ
|
|
Mokhahlelo
3
|
|
Mofuta oa ho Pholisa
ONA
|
|
Voltage ea mantlha
13.8GrdY/7.97 KV
|
|
Motlakase oa bobeli
0.208GrdY/0.12 KV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Angular displacement
YNyn0
|
|
Tšitiso
1.9±10%
|
|
Katleho
99.03%
|
|
Tlanya Range
±2*2.5%
|
|
Mokelikeli oa Mokelikeli
Oli ea Liminerale
|
|
Ha ho Tahlehelo ea Mojaro
0.165KW
|
|
Ho Lahleheloa ke Moroalo
0.9KW
|
|
Lisebelisoa
Tlhophiso e Tloaelehileng
|
1.3 Litšoantšo
75 KVA pad mounted transformer diagram to the size.
![]() |
![]() |
02 Tlhahiso
2.1 Konokono
Ts'ebetso ea tlhahiso ea mantlha ea transformer e kenyelletsa mehato e latelang:
1. Tokiso ea lintho tse bonahalang: Khetha-letlapa la tšepe la silicon le phuthohileng le batang{2} 'me u le khaole ka boholo bo loketseng ho latela litlhoko tsa moralo.
2. Ho bokellana: Ka mor'a ho roala lesela la tšepe la silicon ka pente e sireletsang filimi, beha lesela la silicon ka bonngoe ho ea ka mofuta oa E, mofuta oa C kapa sebopeho sa lesale ho etsa kholomo ea mantlha le joko ea tšepe.
3. Spot tjheseletsa kapa ho tlama: Letlapa la silicon le lokiswa mmoho ka ho tjheseletsa matheba kapa{1}}ka ho tlama ha tshepe ho thibela tse ding ho sisinyeha ka lebaka la matla a makenete a motlakase nakong ya tshebetso.
4. Ka mokokotlo oa mokokotlo kapa o behiloeng: ho ea ka moqapi oa transformer, ho phunyeletsa ka mokoloko oa mantlha kapa ho beha mokokotlong.
5. Tekolo le kalafo: Lekola ho batalla, ho hlaka le boemo ba ho tsikitlanya ha tšepe, 'me u lokise le ho tlatselletsa kalafo ha ho hlokahala.
6. Kopano le liphutheloana: Bokella mokokotlo oa tšepe, matsoelintsoeke, clamping le likarolo tse ling ka har'a kopano ea mantlha ea transformer, le ts'ebetso ea liphutheloana ho etsa bonnete ba hore motlakase o motle le botsitso ba mochini.

2.2 Ho tsubella

Melemo ea foil winding ke: matla a matle a mochini, ho fetoha ha bonolo, ho mamella matla a makhuts'oane-; Matla a motlakase a matle, phepelo e tšoanang ea matla a gradient voltage; Ho fefoha habonolo.
Foil transformer e nka foil e phahameng ea conductivity e le thepa e tsamaisang, botenya ba foil ea aluminium bo ka ba 0.1 ~ 2.5mm, 'me karolo e' ngoe le e 'ngoe ea foil ea terata ke mothinya o le mong.
The conductive foil e entsoe ka pampiri e sireletsang, botenya ke 0.05 ~ 0.12mm, 'me pampiri ea cable e tsamaisang litaemane hangata e sebelisoa. Hobane ho ka 'na ha e-ba le lerōle la tšepe holim'a letlapa la conductive foil, 'me pampiri e sireletsang e tla ba le masoba a manyenyane, -pampiri e sireletsang matla e lokela ho sebelisoa e le mohatlana.
Hlooho le mohatla oa poleiti ea conductive ea foil li cheselitsoe ka terata e tsamaisang (hape e na le clamp e hatellang e batang) joalo ka terata e etellang pele ea matsoeli.
2.3 Tanka
Tanka ea oli ea transformer e cheselitsoe ka poleiti ea tšepe e matla haholo. -Mehato e thibelang makenete e sebelisoa ka har'a tanka ea mafura ho fokotsa tahlehelo. Thebe ea makenete e tsitsitse ebile e sirelelitsoe hantle, e ka qobang ho chesa haholo kapa ho tsoa ho bakoang ke ho se kopane hantle. Mefuta eohle ea lithebe tsa motlakase e na le tsamaiso e ntle le motheo o ka tšeptjoang, ka katleho ho qoba ho tsoa ho emisitsoeng kapa ho ama ntlha ea tahlehelo ea dielectric ea matsoelintsoeke. Ho feta moo, tanka e sebelisa moralo o thibelang -mekhoa ea ho senya le ho penta ka mokhoa o khethehileng oa ho penta, o loketseng libaka tse fapaneng tse thata.

2.4 Kopano ea ho Qetela

1. Kopano ea karolo e sebetsang ea Transformer
E kenyeletsa ho kopanya le ho roala hlooho, coil set, insert plate and clamp, half{0}}thill the body test, lead assembly (ho kenyeletsoa switch assembly, lead making and assembly), halofo{1}}teko e feliloeng ea' mele, le ho omisoa ha 'mele (ho kenyeletsoa le tekanyo ea ho hanyetsa insulation).
2. Kopano kaofela
Sena se kenyelletsa ho qeta le ho tiisa 'mele, ho lekanya ho hanyetsa ha motsoako oa tšepe ho ea fatše, ho hlahloba bohloeki ba' mele le ho tiea ha karolo e 'ngoe le e' ngoe, sebaka sa ho koala ha mohala le moeta-pele, le ho tlatsa oli ka lebokoseng (ho kenyeletsoa ho kenngoa ha lisebelisoa tsa transformer).
03 Ho etsa liteko
1. Karo-karolelano ho likhokahano tsohle le maemo a pompo
2. Ho falla ha angular
3. Ha ho{1}}tahlehelo ea mojaro ka 100% ea matla a motlakase
4. Hona joale e thabisang ho 100% e lekantsoeng ea motlakase
5. Litahlehelo tsa mojaro le impedance ho rated hona joale
6. Matla a sebelisoang
7. Matla a bakoang ke matla
8. Teko ea ho bona ha tanka ea transfoma e dutse{1}.
9. Teko ea ho tsoela pele
04 Ho paka le ho Romela
![]() |
![]() |
05 Sebaka le Kakaretso
Rea leboha ka thahasello ea hau ho-phase ea rona ea mekhahlelo e meraro-e kentsoeng ka transformer! Ka ts'ebetso ea eona e phahameng, likarolo tse ka tšeptjoang tsa ts'ireletso, le ho feto-fetoha ha maemo, sehlahisoa sena se fana ka ts'ehetso ea matla e tsitsitseng le e sebetsang hantle bakeng sa mefuta e mengata ea likopo, e leng se etsang hore e be khetho e nepahetseng bakeng sa mekhoa ea tsamaiso ea indasteri, ea khoebo le ea sechaba. Re ikemiseditse ho fana ka ditharollo tsa boleng-tse tsamaiswang, tse hlahiswang{4}}tse tsamaiswang ho tsamaelana le ditlhoko tsa hao, ho netefatsa ditshebeletso tsa porofeshenale le tse ikgethileng tsa motlakase. Re lebeletse ho aha{{6}tšebelisano ea nako e telele le uena le ho ntšetsa pele katleho le botsitso indastering ea motlakase hammoho! Ho fumana lintlha tse ling, ka kopo ikutloe u lokolohile ho ikopanya le rona neng kapa neng!

Hot Tags: 3 phase distribution transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
75 kVA 3 Phase Pad Mount Transformer-24.94/0.208 kV|...
300 kVA Oli e Tlatsang Transformer-13.2 / 0.48 kV|Gu...
2500 kVA Padmounted Transformers-24.94 / 0.6 kV|Cana...
4000 kVA 3 Phase Pad Mounted Transformer-24.94/0.6 k...
1500 kVA Pad Mounted Transformer Price-23.9/0.416 Kv...
500 kVA Pad Mount Transformer-24 * 13.8 * 12 / 0.416...
Romela Inquiry