315 kVA Vpi Dry Type Transformer-11 / 0.55 kV|Afrika Boroa 2025
Matla: 315kVA
Matla: 10/0.55kV
Tšobotsi: e nang le li-fan le boemo ba H insulation

VPI Dry-Type Transformers: Matla a Sireletsehileng, a Tšepahalang Haholoanyane.
01 Kakaretso
1.1 Tlhaloso ea Morero
Transformer ea 315 kVA e bulang matsoelintsoeke ea mofuta o omileng e ile ea isoa Afrika Boroa ka 2025. Matla a lekantsoeng a 315 kVA e nang le pholiso ea AN/AF, motlakase oa mantlha ke 11 kV le ±2*2.5% tapping range (NLTC), motlakase oa bobeli ke 0.55kV, ba thehile sehlopha sa vector ea Dyn11.
Sehlahisoa sena ke mofuta o bulehileng-, oa mofuta oa H o omileng-mofuta oa transformer o entsoeng ka theknoloji e tsoetseng pele ea Vacuum Pressure Impregnation (VPI), e etselitsoeng haholo maemo a thata a indasteri. Maqhubu a eona a etsa liphekolo tse ngata tsa VPI ho theha sekhahla se teteaneng sa H, se fanang ka khanyetso e ikhethang ho mongobo, lerōle le kutu. E hlophisitsoe ka lisebelisoa tsa ho kenya letsoho tsa Sehlopha sa H le ho phahama ha mocheso ka 100K, e fana ka moeli o moholo oa mocheso, e netefatsa bophelo bo atolositsoeng ba ts'ebeletso le matla a holimo a holimo le tlas'a{5}}maemo a phahameng a mocheso. Mohaho o ikhethang o bulehileng-, o kopantseng le lifenehi tse pholileng, o nolofalletsa mocheso oa othomathike{8}}o laolang moea o pholileng o qobelloang, o matlafatsang haholo{9}bokhoni ba ho tlala nako e khuts'oane le ho nolofalletsa ts'ebetso e ts'epahalang tlas'a tšusumetso e matla. E na le oli{11}moetso o sa sebetseng-o sa sebetseng lelakabe, e fana ka polokeho le ts'epahalo, e lokiselitsoe lisebelisoa tsa motlakase oa 110V, 'me e sebelisoa haholo lifemeng tsa liindasteri, litsing tsa boitsebiso, lipalangoang tsa literene, le lits'ebetsong tse ling tse hlokang ts'ireletso e phahameng le ho tšepahala phepelong ea motlakase.
1.2 Tlhaloso ea Setsebi
Tlhaloso ea 315 kVA VPI ea mofuta o omileng le leqephe la data
|
E fetisetsoa ho
Afrika Boroa
|
|
Selemo
2025
|
|
Mofuta
Bula mofuta o omileng oa transformer e omeletseng
|
|
Boitsebiso ba mantlha
Letlapa la tšepe la silicon le entsoeng ka lijo-thollo
|
|
Standard
IEC60076
|
|
Rated Power
315kVA
|
|
Khafetsa
50HZ
|
|
Sehlopha sa Vector
Dyn11
|
|
Mokhahlelo
3
|
|
Mofuta oa ho Pholisa
ONAN/ONAF
|
|
Voltage ea mantlha
11 kV
|
|
Motlakase oa bobeli
0.55 kV
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
4%
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
±2*2.5%@lehlakoreng la mantlha ka ho tlanya lihokelo
|
|
Ha ho Tahlehelo ea Mojaro
1.1KW
|
|
Ho Lahleheloa ke Moroalo
4.1KW
|
|
Boemo ba insulation
H
|
|
Mocheso oa moea o nyoloha @rated lehlakoreng la tšebeletso
100K
|
1.3 Litšoantšo
315 kVA VPI mofuta o omileng oa setšoantšo sa sefetoleli sa setšoantšo le boholo.
![]() |
![]() |
02 Tlhahiso
2.1 Ntlha ea bohlokoa
Moko o hahiloe ka-ka letlapa la tšepe la boleng bo holimo- le entsoeng ka silicon. Sesebediswa sena se khethehileng se entsoe ka laminated ka hloko le ho lemala ho fokotsa tahlehelo ea mantlha le ho eketsa ts'ebetso ea makenete. Mabele a eona-sebopeho se shebaneng le sona se fokotsa haholo hysteresis le tahlehelo ea hona joale ea eddy, e netefatsa hore matla a khoheli a khona ho kenella ka matla 'me ha a sebelisoe{5}karolo e tlase. Boenjineri bo nepahetseng ba mantlha bo thusa ho sebetsa hantle haholo ha transformer, ho sebetsa ha lerata le tlase, le ho boloka matla ka kakaretso-.
2.2 Ho tsubella
Likhoele li sebelisa{{0}likhondara tsa aluminium tse hloekileng, vacuum-pressure impregnated (VPI) tse nang le-varnish ea insulating e phahameng. Ts'ebetso ena e etsa hore ho be le setaele se tiileng,{4}}se sa keneleng mongobo se tiisang botsitso bo botle ba mocheso, matla a mochini, le ts'ebetso e tšepahalang tlas'a maemo a boima.

2.3 Kopano ea ho qetela

Kopano ea ho qetela ea VPI e omeletseng-ea mofuta oa transformer e kopanya core e kentsoeng le likhoele ka har'a sebopeho sa mochini o tiileng, o kentsoeng ka mokhoa o sireletsehileng ka li-fasteners{1}}tse sa tsitsang. Likhokelo tsa motlakase li sebetsa ka nepo{{3}li felisitsoe ka lihokelo-tse matla a holimo, ha lifenehi tse pholisang le lithebe tse sireletsang li kentsoe ho netefatsa taolo e nepahetseng ea mocheso le polokeho ea ts'ebetso.
03 Teko
Teko ea VPI ea mofuta o omileng oa transformer (315kVA-11/0.55kV) ho 2024/12/5, ho latela maemo a IEC, ho koaheloa ha maqhubu (ho se leka-lekane), karolelano ea voltage/mohato (ho kheloha ho honyenyane, Dyn11), liparamente tse khutšoane tsa potoloho/no-load, li-parameter tsa discharge le karolo e lekanang le Leno 10pC). Liphetho tsohle li ile tsa kopana le litlhoko, tsa tšoaneleha.
|
Che. |
Ntho ea Teko |
Yuniti |
Melao ea ho Amohela |
Litekanyetso Tse Lekanyelitsoeng |
Qetello |
|
|
1 |
Tekanyo ea ho hanyetsa matsoelintsoeke |
/ |
Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane Khanyetso ea mela: e ka tlase ho kapa e lekana le 2% |
HV (mohala) |
LV (mohala) |
Feta |
|
0.37% |
0.58% |
|||||
|
2 |
Tekanyo ea karo-karolelano ea motlakase le ho hlahloba phallo ea mohato |
/ |
Mamello ea karo-karolelano ea motlakase ho theipi ea mantlha: ± 1/10 Letšoao la khokahano: Dyn11 |
0.02% ~ 0.18% Dyn11 |
Feta |
|
|
3 |
Tekanyo ea -nako e Khutšoane ea Impedance le Loss Loss |
/ kW kW |
T:120 likhato Z%: boleng bo lekantsoeng Pk: boleng bo lekantsoeng Pt: boleng bo lekantsoeng |
4.27% 2.390 3.329 |
Feta |
|
|
4 |
Tekanyo ea Ha ho-Tahlehelo ea Mojaro le Hona Joale ho 90% le 110% ea matla a matla a motlakase |
/ kW |
I0 :: fana ka boleng bo lekantsoeng P0: fana ka boleng bo lekantsoeng |
90% Ur |
0.81 0.9198 |
Feta |
|
100% Ur |
0.90 1.022 |
|||||
|
110% Ur |
0.99 1.124 |
|||||
|
5 |
Teko ea Voltage e sebelisitsoeng |
/ |
HV: 35kV 60s LV: 3kV 60s |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
|
6 |
Teko ea ho mamella Voltage e kentsoeng |
/ |
Matla a sebelisoang (KV): 2 Ur Matla a hlahisoang ke matla (KV): 1.1 Nako:40 Hangata (HZ): 150 |
Ha ho ho putlama ha motlakase oa liteko |
Feta |
|
|
7 |
Teko ea Phallo e sa Feleng |
pC |
Boemo bo phahameng ba ho tsoa ha karolo e itseng e tla ba 10 pC |
<10 |
Feta |
|


04 Ho paka le ho Romela
4.1 Ho paka
VPI dry{0}mofuta oa transformer e pakiloeng ka mokhoa o sireletsehileng ho sebelisoa boemo ba leholimo-ba hanyetsanang le lintho tse tšosang{2}}tse monyang. Transformer e kentsoe ka thata ka har'a crate e tloaelehileng ea lepolanka, e nang le padding e eketsehileng e sireletsang ho thibela ho sisinyeha nakong ea leeto. Likarolo tsa bohlokoa li koahetsoe ke mongobo{{5}lithibelo tse thibelang mongobo, 'me thepa kaofela e ngotsoe ka ho hlaka ka litaelo tsa ho sebetsana le lintlha tsa tekheniki ho netefatsa hore tsamaiso e bolokehile le e sebetsang hantle.
4.2 Ho tsamaisa thepa
Tlas'a lipehelo tsa CIF (Cost, Insurance, and Freight), VPI dry{0}type transformer e tla romelloa boema-kepeng ba Durban, Afrika Boroa. Morekisi o sebetsana le thepa ea maoatle le inshorense ea maoatleng, e netefatsa hore ho tsamaea ka tsela e sireletsehileng maemong a leholimo-e thibelang mafu a leoatle-a phutheloa ka maemo. Litokomane tsohle tse hlokahalang tsa thomello (bili ea thepa, setifikeiti sa inshorense, invoice ea khoebo) li fanoe bakeng sa tumello e nepahetseng ea moetlo sebakeng seo u eang ho sona. Kotsi e fetisetsoa ho moreki ha a laolloa boema-kepeng ba Durban.
05 Sebaka le Kakaretso
VPI dry{0}mofuta oa transformer e eme e le motheo oa litsamaiso tsa sejoale-joale tsa motlakase, tse kopanyang ts'epahalo e ke keng ea lekanngoa le{1}}matla a boenjiniere. Ka thekenoloji ea Vacuum Pressure Impregnation (VPI), Mokhahlelo oa H, le taolo e bohlale ea ho laola mocheso, e fana ka ts'ebetso e ikhethang,{3}}polokeho e hanyetsanang le malakabe, le ts'ebetso e matla maemong a boima haholo. Ho tloha kabong ea motlakase liindastering le ho kopanngoa ha matla a ka nchafatsoang ho isa lits'ebetsong tsa bohlokoa tsa ts'ebetso, mofuta oa VPI o omileng- transformer e sebetsa ka mokhoa o khutsitseng, o netefatsa hore motlakase o hloekile ebile o tsitsitse lefatšeng ka bophara. Ho khetha transformer ena ho bolela ho tsetela ho ts'ireletso e tsitsitseng ea matla le bokhabane ba ts'ebetso bakeng sa bokamoso.
Hot Tags: vpi mofuta o omileng oa transformer, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
630 kVA Vpi Mofuta oa Transformer-11 / 0.55 kV|Afrik...
630 kVA Vacuum Pressure e Kentsoeng Transformer-11/0...
1000 kVA Vpi Transformer-11 / 0.55 kV|Afrika Boroa 2024
630 kVA Dry Type Step Down Transformer-11/0.55 kV|Af...
630 kVA Mofuta o omileng oa Power Transformer-11/0.5...
630 kVA General Electric Dry Type Transformers-11 / ...
Romela Inquiry