112.5 KVA Pole Mounted 3 Phase Transformers-13.8/0.208 KV|Canada 2025

112.5 KVA Pole Mounted 3 Phase Transformers-13.8/0.208 KV|Canada 2025

Naha: Canada 2025
Matla: 112.5 kVA
Matla: 13.8D-0.12/0.208kV
Feature: e nang le sesupo sa boemo ba oli
Romela Inquiry

Jiangshan Scotech Electrical Co., Ltd ke e 'ngoe ea baetsi le barekisi ba tšepahalang ba 112.5 kva poles 3 phase transformer{7}}13.8/0.208 kv|Canada 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

 

pole mounted 3 phase transformers

Tsepameng ka holimo, Matla a Bophelo ka tlase. Tse Tšeptjoang Pole Mounted Transformers.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

112.5 kVA e tharo phase pole mounted transformer e ile ea isoa Canada ka 2025. Matla a lekantsoeng a transformer ke 112.5 kVA e nang le pholiso ea ONAN. Matla a phahameng ke 13.8D kV le ± 2 * 2.5% tapping range (NLTC), motlakase o tlaase ke 0.12 / 0.208 kV, ba thehile sehlopha sa vector sa Dyn1.

Sesebediswa sena sa 112.5kVA -phase three pole-transformer ke sesebediswa{3}}se sebetsang hantle haholo ho fetola matla a mantlha-marang-rang a kabo ya motlakase o tlase, se sebetsang e le karolo ya bohlokwa ya kabo ya ditheminale tsa marangrang a phano ya diteropo, makala a dibaka tsa diindasteri, le sistimi ya phepelo ya motlakase dibakeng tse hole. E sebelisa palo-mohaho o kentsoeng ka mokhoa o fanyehiloeng, o nang le thepa e ka ntle{7}}e thibelang ho bola{8}}ka mafome le mafome{9}e tiisitsoeng e tiisang mafome le 13.8kV{11}}mokhoa oa li-insuspension bushings, tse loketseng ho romelloa holimo holimo. Sesebelisoa sa ho laola motlakase se behiloe karolong ea eona e phahameng-ea motlakase, e nolofalletsang ±2*2.5% ho lokisa motlakase-ho ikamahanya le ho feto-fetoha ha grid le ho netefatsa hore motlakase o fela-mosebetsing.

E na le lintlha tse 112.5kVA, e ts'ehetsa 13800V medium-voltage input le 208V/120V low-voltage output. Ka tlas'a{{7}maemo a mararo a ho laela, e ka nka{8}Tlhahiso ea nako e tlase{9}}lehlakoreng la "voltage" e tlase{10}e khonang ho fana ka{11}mokhahlelo oa boraro bakeng sa lisebelisoa tsa indasteri, ha e ntse e khotsofatsa litlhoko tsa motlakase oa mabone a mohato o le mong bakeng sa basebelisi ba khoebo le ba bolulo. Matla a eona a ho fetola matla a matla a feta 98.74% tlas'a mojaro o lekantsoeng, ka katleho ho fokotsa tahlehelo ea matla ho sehokelo sa kabo.

Transformer ena e sebetsa haholo maemong a kenyeletsang tokiso ea marang-rang a kabo ea litoropo (ho rarolla mathata a mangata libakeng tsa khale), kabo ea lekala la liindasteri (ho ts'ehetsa phepelo e tsoelang pele ea motlakase bakeng sa lithupelo tse nyane le tse mahareng-), tšireletso ea phepelo ea motlakase libakeng tse hole (ho tlatsa likheo tsa motlakase libakeng tsa mahaeng le litoropong), le maemo a nakoana a motlakase ka ntle (joalo ka liketsahalo tse kholo). Ha ho bapisoa le li-transformer- tse palamisitsoeng fatše, ha li boloke sebaka sa fatše feela empa hape li ntlafatsa ts'ireletseho ea ts'ebetso le tlhokomelo ka ho ba hole le libaka tsa mesebetsi ea basebetsi. Bokhabane ba eona bo phahameng ba ho kenya letsoho le moralo o thibelang-khoholeho ea ho senya ho thusa ho phela lilemo tse fetang 20, ho fokotsa haholo-litšenyehelo tsa nako e telele tsa ts'ebetso le tlhokomelo. Ho sa le joalo, ts'ebetso ea eona ea taolo ea motlakase e ka fokotsa tšusumetso ea ho feto-fetoha ha motlakase ho lisebelisoa tse nepahetseng, ea e etsa khetho e ka sehloohong bakeng sa ntlafatso ea marang-rang ka compactness, ts'epo e phahameng, le maemo a maemo.

 

 

 

1.2 Tlhaloso ea Setsebi

112.5 kVA pole mounted transformer specifications type le data sheet

E fetisetsoa ho
Canada
Selemo
2025
Mofuta
Pole mounted transformer
Standard
CSA C2.2-06
Rated Power
112.5 kVA
Bophahamo
Ka tlase ho kapa ho lekana le 1000m
Khafetsa
60HZ
Mokhahlelo
1
Mofuta oa ho Pholisa
ONA
Voltage ea mantlha
13.8D kV
Motlakase oa bobeli
0.208/0.12 kV
Lintho Tse Hlahang
Aluminium
Tšitiso
3.5%
Katleho
E kholo ho feta kapa e lekana le 98.74%
Tlanya Changer
±2*2.5%
Ha ho Tahlehelo ea Mojaro
0.475 kW
Ho Lahleheloa ke Moroalo
1.06 kW
Mmala
ANSI Grey70#

 

1.3 Litšoantšo

112.5 kVA poling mounted transformer diagram to the size and size.

pole mounted 3 phase transformers diagram pole mounted 3 phase transformers nameplate

 

 

02 Tlhahiso

2.1 Tanka

pole mounted 3 phase transformers oil tank

Ena ke tanka ea 112.5kVA three-pase phase pole{2}} transformer e phahamisitsoeng, e entsoeng ka tšepe e tiileng 'me e entsoe ka semi-e felileng (e kentse grey primer). E na le sebopeho se nang le li-welded tse nang le li-rectangular: holimo ho kenyelletsa li-interfaces bakeng sa likarolo tsa mantlha tsa transformer, ha menyetla e 4 e ka pele e chitja e boloketsoe wiring / lisebelisoa. E kopantsoe le likoahelo tse tiisitsoeng (tse bonoang haufi le moo), e tla boloka likarolo tse ka hare, e tšoara oli e sireletsang (bakeng sa ho pata le ho senya mocheso), le ho sireletsa likarolo tsa ka hare ka mor'a kopano e feletseng.

 

2.2 Kopano ea ho Qetela

Sena ke sebaka sa ho qetela sa kopano ea 112.5kVA{1}}mohato oa 112.5kVA three-transformer e phahamisitsoeng, 'me ts'ebetso e ntseng e tsoela pele ha joale. Tse bonahalang mona ke likaroloana tsa mantlha tsa transformer (ho kenyeletsoa-mohato o tharo{4}}o phuthetsoeng ka mokelikeli o mosoeu), 'me mosebeletsi o tšoara lithapo tsa koporo tse bobebe tsa beige{5}} oa li tjheseletsa ho hokela mapheo le litheminale tsa kantle (mohato oa bohlokoa oa ho netefatsa phetiso ea motlakase e tsitsitseng). Lisebelisoa tse tloaelehileng tsa kopano (joaloka lisekere le li-wrenches) li robetse haufi; khokahanyo ena ea lithapo ke sehokelo sa bohlokoa sa motlakase kopanong ea ho qetela, se rala motheo oa ho tiisa le ho etsa tlhahlobo ea tšebetso e latelang.

pole mounted 3 phase transformers assembled

 

2.3 Sesebelisoa sa ho Pholosa Khatello

Pressure Relief Device

Sesebediswa sa ho imolla kgatello se kentsweng ho 112.5kVA three-phase phase pole-transformer e palamisitsweng ke karolo ya bohlokwa ya polokeho e etseditsweng ho ntsha ka potlako digase tse hlahiswang ka hare ha ho ka ba le phoso e kgolo ka hare kapa kgatello e matla haholo. E sebetsa joalo ka mokhoa o sireletsehileng oa mochini, o kenya tšebetsong hang-hang ho thibela ho phatloha ho hoholo ha tanka ka ho lokolla khatello ka boema-kepe bo inehetseng, ka hona ho fokotsa kotsi ea mollo, ho phatloha le tšenyo ea lisebelisoa. Ka tloaelo se na le folakha e bonoang kapa sesupo se bonts'ang ts'ebetso, sesebelisoa se thusa ho sireletsa bots'epehi ba sebopeho sa transformer le ho netefatsa ts'ireletseho ea lits'ebetso tsa ts'ebeliso le basebetsi. Ha e se e kentsoe, e hloka tlhahlobo ea letsoho le ho seta bocha nakong ea tokiso e latelang.

 

2.4 Tlanya Changer

Tap changer e nang le 112.5kVA three-pase phase pole-transformer e lumang ke WSLⅡ3 63/20-6×5 off-mofuta oa potoloho, sesebelisoa sa bokahohle se etselitsoeng oli{9}}li-transformer tse qoelitsoeng ho e-na le yuniti e tloaelehileng. E kentsoe karolong e phahameng-ea motlakase oa transfoma, 'me e na le matla a rekanyelitsoeng a 20kV le matla a hajoale a 63A, 'me e na le maemo a 5 a lumellang hore ho be le ±2×2.5% taolo ea matla a motlakase-ho fihlela phetoho e tsitsitseng ea motlakase ka ho fetola palo ea likheo tsa motlakase. E le karolo ea bohlokoa bakeng sa ho tsitsisa ha motlakase, e tlameha ho sebelisoa ha transformer e felloa ke matla{18}}ho netefatsa hore e fetoha ka mokhoa o sireletsehileng, e lefang hantle ho feto-fetoha ha motlakase oa grid le ho boloka motlakase o tlase o sa fetohe bakeng sa basebelisi.

Moetso oa eona o matla o tsamaisana le tšebetso e ka ntle ea transformer{0}}e hloellang, e mamella maemo a thata a tikoloho ha e ntse e netefatsa hore e sebetsa ka botšepehi nakong eohle-ea ts'ebeliso ea nako e telele.

Tap Changer

 

2.5 Letšoao la Boemo ba Oli

Oil Level Indicator

Letšoao la boemo ba oli ke mofuta o tloaelehileng oa UHZ-01, sesebelisoa sa bokahohle se etselitsoeng oli e mahareng le e nyane-liphetoho tse qoelitsoeng ho fapana le yuniti e ikhethileng. E kentsoe ka kotloloho ka lehlakoreng la sebatli sa oli sa transformer, e sebetsa ho ipapisitse le melaoana ea ho hokahana le ho kopanya matla a khoheli: float e kahare e tsamaea ka mokhoa o ts'oanang le boemo ba oli e sireletsang, e khanna lets'oao la kantle ho bonts'a ka ho hlaka boemo ba mokelikeli bo nkang sebaka sa li-tube gauge tsa setso ka polokeho e ntlafalitsoeng, ponahalo le nako e telele. E etselitsoe ho mamella maemo a thata a kantle, e na le mocheso o pharalletseng oa ho sebetsa oa likhato tse 40 ho isa ho 80, e ikamahanya le mongobo o fihlang ho 90% (ka likhato tse 25), 'me e sebetsa ka botšepehi libakeng tse Ka tlase kapa tse lekanang le 2000m ntle le ho angoa ke ho thothomela ho matla kapa matla a makenete. E le karolo ea bohlokoa ea ho beha leihlo, e lumella basebetsi ba tlhokomelo hore ba hlahlobe kapele boemo ba oli, ho netefatsa ts'ebetso e lekaneng ea ho pata le ho senya mocheso oa transformer le ho tšehetsa ho rarolla mathata ka nako ho qoba likotsi tsa ts'ebetso tse bakoang ke khaello ea oli kapa ho phalla.

 

2.6 Tlase-Motlakase oa Motlakase

The low{{0}voltage bushing of this 112.5kVA three-phase phase pole-mounted transformer is the standard model 251101-12XD.401.004.B, e leng sesebediswa sa bokahohleng sa oli{8}}li-transformer tse qoeletseng. E behiloe ka lehlakoreng la tanka, 'me e entsoe ka fiber ea khalase-e tiisitsoeng ka thermoset polyester bakeng sa ho hanyetsa boemo ba leholimo, e loketseng mesebetsi e katiloeng ka ntle{15}. E fane ka lintlha tsa 208V/120V ea transformer e nang le matla a Ho feta kapa a lekanang le 200A (e fetang 158A low{16}voltage rating), e na le{19}}teminale ea koporo e pentiloeng bakeng sa likhokahano tse tšepahalang. E ipapisa le maemo a 1.2kV a ho kenya letsoho 'me e na le litiiso tse sa lutlang{20}, e fetisa matla a motlakase o tlase ka mokhoa o sireletsehileng ha e ntse e sireletsa lisebelisoa tsa ka hare.

Low-Voltage Bushing

 

2.7 High{1}}Voltage Bushing

High-Voltage Bushing

The high{{0}voltage bushing of this 112.5kVA three-phase pole{3}}mounted transformer is the standard model 12XD.401.010-A, sesebelisoa sa bokahohleng sa oli{12}}li-transformer tse qoelitsoeng. E behiloe holim'a tanka, 'me e na le 'mele oa porcelain le liteishene tsa koporo, tse behiloeng 18KV/55A ka sebaka sa creepage E kholo ho feta kapa e lekanang le 450.85mm le 125KV le lehalima le mamella voltage, e netefatsa hore motlakase o fetisoa ka mokhoa o sireletsehileng{13}}bakeng sa ts'ebetso ea ka ntle.

 

 

03 Ho etsa liteko

112.5kVA ena-mohato oa karolo-transfoma e phahamisitsoeng (mohlala: 112.5kVA-13.8DELTA-0.208/0.12kV) e entse liteko tse tloaelehileng ho ea ka CSA C2.1-06(R2022) le CSA C802.2 voltage standard (R2022, R2022,20,2,2,2,2,2,2, 2, 2, 2, 2, 2020, 2020 mamella teko, tlhahlobo ea ho hanyetsa mocheso, le tlhahlobo ea ho lutla ha 24h ho 20kPa. Lintho tsohle tse fetisitsoeng: katleho e fihlile ho 98.94%, khanyetso ea insulation e ile ea kopana le litlhoko, ha ho na ho lutla ho etsahetseng, 'me matšoao a bohlokoa a kang tahlehelo ea mojaro le motlakase oa impedance o tsamaellana le litlhaloso.

pole mounted 3 phase transformers test
pole mounted 3 phase transformers routine tests

 

 

04 Ho paka le ho Romela

pole mounted 3 phase transformers packing
pole mounted 3 phase transformers shipping

 

 

05 Sebaka le Kakaretso

E le -sesebediswa sa ho aba matla a hodimo se ikamahanyang le maemo a matjhaba a CSA (CSA C2.1-06(R2022) & CSA C802.1-13(R2022)) mme se netefaditswe ka botlalo ka diteko tse felletseng, 112.5k}karolo ena e 112.5k}e ntlafaditse{1}karolo ya boraro{} e sebetsang hantle ka 98.74% ea phetoho e phahameng, ts'ebetso e tsitsitseng ea motlakase, le moralo o matla oa ts'ireletso ea kantle. E ikamahanya hantle le maemo a fapaneng a joalo ka nchafatso ea marang-rang a kabo ea litoropo, phepelo ea motlakase ea lirapeng tsa indasteri, le tšireletso ea motlakase ea libakeng tse hole. Ho kopanya ts'ireletso e lumellanang le ts'ireletso, taolo e nepahetseng ea motlakase,{13}}thibelo ea nako e telele{14}}thibelo ea nako e telele, le litšenyehelo tse tlase tsa ts'ebetso le tlhokomelo, ha e fihlelle feela{16}litlhoko tsa mantlha tsa basebelisi bakeng sa botsitso ba motlakase, empa hape e tsamaisana le maikutlo a ho boloka matla a{17} a bolokang marang-rang a phano. Tharollo e tšepahalang, e sebetsang hantle, le e sebetsang ea kabo ea matla, e fana ka ts'ehetso e tsoelang pele le e ts'eptjoang ea matla bakeng sa maemo a fapaneng a ts'ebeliso ea matla a tlase.

CSA international standards

 

Hot Tags: pola e kentsoeng li-transformer tsa 3 phase, moetsi, mofani oa thepa, theko, litšenyehelo

Romela Inquiry