Selelekela

 

 

Li-transformer tse kentsoeng ka Pad{{0}ke karolo ea bohlokoa ea kamoo meaho ea sejoale-joale e fumanang matla a eona. Ha li kentsoe ka ntle ka khabiteng e koetsoeng ka botlalo, li nka{2}}motlakase oa motlakase o mongata ho tloha setsing se sebetsang ebe li o theolela ho matla a tlase ao meaho e a sebelisang letsatsi le letsatsi.
Boholo ba meaho ea khoebo e sebetsa ka-ka motlakase oa mekhahlelo e meraro. Pad-li-transformer tse kentsoeng li fetola phepelo ena hore e be li-voltage tse tloaelehileng tse kang 208Y/120 V kapa 240/120 V, tse tšehetsang mabone, lisebelisoa tsa HVAC, li-elevator le li-plug tse akaretsang mohahong kaofela.

commercial-buildings-power-distribution-pad-mounted-transformer

 

Libakeng tsa 'nete tsa khoebo-litsi tsa mabenkele, litora tsa liofisi, lihotele, kapa likolo-mejaro e fapane,' me hangata e tsamaisoa ka nako e le 'ngoe. Li-Pad-li-transformer tse kentsoeng li hahiloe ho sebetsana le motsoako ona ka ts'epahalo, ha lisebelisoa tsa motlakase li le ka ntle ho sebaka seo motho a lulang ho sona. Sengoliloeng sena se sheba hore na li-transformer tsena li sebelisoa joang meahong ea khoebo, le hore na hobaneng meralo ea SCOTECH e loketse lits'ebetso tsena.

 

 

Kakaretso ea Kopo

 

 

commercial-pad-mounted-transformer-outdoor

 

Tšebeliso ea mantlha

Liwebsaeteng tsa khoebo (libaka tsa mabenkele, liofisi, lihotele, joalo-joalo), li- pad-li-transformer tse kentsoeng hangata li kengoa ka ntle ho fana ka meaho ea motlakase. Li hokela ho lithapo tsa ka tlas'a lefatše 'me li fetolela matla a mahareng-voltage (MV) (mohlala, 5–35 kV) ho ea ho litšebeletso tse tlase-voltage (LV) (mohlala, 208Y/120 V kapa 480Y/277 V) bakeng sa kabo ea moaho.

Meroalo e Sebeletsoeng

Meroalo e tloaelehileng e kenyelletsa lipotoloho tsa mabone, lisebelisoa tsa HVAC (li-motor, li-fan, li-chiller), li-escalator/elevator, lisebelisoa tsa tšireletso le li-plug outlets. Meroalo ena hangata e tsamaea ka nako e le 'ngoe nakong ea lihora tsa khoebo, ka hona, li-transformer li na le boholo bo lekaneng ba kVA ho sebetsana le tlhokeho e phahameng ka ho fetisisa.

Sekala

Meaho ea khoebo e fapana haholo ka boholo, kahoo -litumellano tsa marang-rang li ka tloha ho tse nyane (ka mashome a kVA bakeng sa thepa ea lehae) ho ea ho liyuniti tse kholo (MVA tse 'maloa bakeng sa mabenkele a maholo kapa likhamphani tsa liofisi). SCOTECH e ka fana ka karolo-mohato o le mong kapa tse tharo-ho lumellana le litlhoko tsa moaho ofe kapa ofe.

Khokahano

Hangata li-transformer tsena li hokahana le lisebelisoa tse kholo tsa moaho kapa monyako oa litšebeletso. Li ka hlophisoa bakeng sa likhokahano tsa loop-feed kapa radial-feed to the utility cables, e leng se lumellang lipeakanyo tse feto-fetohang tsa phepelo. {{4}likhampase tse ngata tse ahang li ka sebelisa li-pad tse ngata-litumellano tse bapileng kapa tse tlanngoeng ke li-switchgear bakeng sa ho fokotsoa.

 

 

Tlhophiso e Tloaelehileng ea Tsamaiso Meahong ea Khoebo

 

 

Ka mokhoa o tloaelehileng oa ho seta, u tla fumana transformer e kentsoeng fatše e lutseng fatše holim'a motheo oa konkreite, e hoketsoeng le marangrang a -voltage a mahareng ka lithapo tsa ka tlas'a lefatše. E theola matla a motlakase a mantlha-hangata 12.47 kV kapa 13.8 kV-ho ea ho maqhubu a bobeli a kang 480Y/277 V kapa 208Y/120 V bakeng sa kabo ea kahare ea moaho.
Litlhophiso tse tloaelehileng li kenyelletsa:

  • Lisebelisoa tsa li-radial feed, tse sebetsang hantle bakeng sa lisebelisoa tse nyenyane kapa tse le 'ngoe{0}} tsa mohaho
  • Sistimi ea phepelo ea Loop, e fanang ka ts'epo e eketsehileng le bosholu bakeng sa li-complexes tse kholoanyane
  • Ho hokahana le li-switchgear le lisebelisoa tse sirelletsang, kahoo o ka hokahanya ts'ireletso ea liphoso le ho arola transformer ka mokhoa o sireletsehileng nakong ea tlhokomelo.
commercial-building-power-supply-system

Ha e le hantle, tokisetso ena e boloka matla a tsitsitse 'me a tsoela pele, e etsa hore tlhokomelo e be bonolo libakeng tseo batho ba leng teng, 'me e u fa monyetla oa ho atolosa bokhoni ha mohaho o ntse o hōla kapa o fetoha.

 

Litlhoko tsa Bohlokoa tsa Tekheniki bakeng sa Likopo tsa Kaho ea Khoebo

 

 

urban-commercial-pad-mounted-transformer

 

Ha u hlakisa pad-li-transformer tse kentsoeng molemong oa khoebo, baqapi le beng ba tsona ba sheba lintlha tse latelang:

Voltage le Bokhoni

Diyuniti di tlameha ho tsamaellana le matla a motlakase a tshebeletso (HV le LV) mme di tsamaise moroalo wa moaho ka sekgahla. Litekanyetso tse tloaelehileng li tloha ho 75 kVA ho ea ho MVA tse 'maloa bakeng sa meaho ea khoebo. Mefuta e le 'ngoe-ea mokhahlelo o le mong (ho fihla ho ~ 250 kVA) e boetse e sebelisoa bakeng sa meaho e menyenyane kapa -li-circuits tsa mekhahlelo. SCOTECH e ka etsa{7}}karolelano ea motlakase oa moenjiniere le kVA ho latela litlhoko tsa bareki.

Katleho

Ho sebetsa hantle ha matla ho bohlokoa ho fokotsa tahlehelo le litšenyehelo tsa ts'ebetso. Li-transformer kaofela tsa pad- li kopana kapa li feta maemo a sebetsang hantle a DOE le litataiso tsa tahlehelo tsa ANSI/IEEE. Li-cores tsa tšepe tsa boemo bo holimo{{3}tse phahameng-le meralo e tlase-li thusa ho ntlafatsa ts'ebetso. Mefuta e mengata e fana ka-tahlehelo e tlase (mohlala, Amorphous core) likhetho.

Tlhaloso ea molumo

Lerata le ka ama liofisi kapa libaka tsa bolulo tse haufi. Lithapa tsa marang-rang-li etselitsoe ho sebetsa ka khutso (hangata 55–65 dBA kapa ka tlase). Kopano ea mantlha le tanka e ntlafalitsoe ho fokotsa ho thothomela. Haeba ho hlokahala, -mehato e thibelang lerata kapa maemo a itseng a molumo a ka fanoa.

Ho futhumatsa le ho futhumatsa

Boholo ba marang-rang a marang-rang-ke oli{1}}e qoelitsoeng (ONAN cooling). Lioli tse thibelang mocheso (liminerale kapa tse ka tlaase ho{3}}ester e ka tukang) li ntša mocheso o tsoang matsoelineng. Bakeng sa maemo a holimo, likhetho tse qobelloang-oli kapa moea o qobelloang{6} li teng. SCOTECH e fana ka likarolo tse nang le oli ea liminerale kapa FR3 ester fluid ho latela khetho ea bareki le litlhoko tsa khoutu.

Sebaka se koaletsoeng le Tšireletso

Tanka ea ka ntle ea tšepe e tlameha ho mamella boemo ba leholimo 'me e se ke ea bola- Likarolo tsa ka hare li koaletsoe ho thibela ho kena likarolong tse matlafetseng. Li-Surge arresters li ka kenngoa ka lehlakoreng la HV bakeng sa tšireletso ea lehalima.

Polokeho le Boikamahanyo

Li-transformer li tlameha ho latela melao le litekanyetso tsa motlakase, ho kenyeletsoa letoto la ANSI/IEEE C57 le manane a polokeho a UL kapa CSA. SCOTECH e haha ​​​​ho ea ka litekanyetso tsena, 'me lihlahisoa tsohle li thathamisitsoe ho UL/CUL le ho ngolisoa bakeng sa kopo e boletsoeng.

Ho fihlella le Tlhokomelo

Litokisetso tsa tlhokomelo li kenyelletsa li-valve tsa oli-li-fill and drain, oli{1}}level le li-gauge tsa thempereichara, le li-tap changer tse fumanehang habonolo. Hangata li-pad mounts li kenyelletsa liporo tsa skid kapa likopano tsa jacking bakeng sa ho tlosoa. Litokollo tse pota-potileng yuniti li tlameha ho bolokoa, tseo SCOTECH e li netefatsang ka tataiso e nepahetseng ea moralo le ts'ebetso.

Tšireletso ea Phoso ea fatše

Li-transformer tse phahameng- tsa kVA li ka 'na tsa hloka tšireletso ea fatše. SCOTECH e ka kopanya li-relay tse hlokahalang tsa ts'ireletso kapa ea sebetsa le liphanele tse holimo ho fihlela litlhoko tsena.

 

 

Hobaneng ha li-transformer tse kentsoeng Pad li Ratoa Meahong ea Khoebo

 

 

Li-transformer tse kentsoeng ka pad li tlisa melemo e mengata e sebetsang bakeng sa lits'ebetso tsa khoebo:
Tšireletseho pele:e kentsoeng ka botlalo, -ea ho kenya tšebetsong boemo bo fokotsa ho pepesehela likarolo tse phelang
Ponahalo e hloekileng:tikoloho e kopaneng le e sa bonahaleng, e loketseng naha kapa tikoloho ea litoropo
Ka tlas'a lefatše{0}e lokile:e sebetsa ka mokhoa o ts'oanelang le lisebelisoa tsa lithapo tsa ka tlas'a lefatše, e seha mela e holimo
Moralo oa sistimi e feto-fetohang:e ts'ehetsa litlhophiso tsa phepelo ea radial le loop
Tlhokomelo e tlase:litanka tse tiisitsoeng le kaho e tšoarellang ha li boloke tlhokomelo e nyane
Ka bokhuts'oane, ke tharollo e tšepahalang, e sebetsang e fihlelang litlhoko tsa meaho ea sejoale-joale ea khoebo.

 

 

Hobaneng U Khetha SCOTECH bakeng sa Merero ea Kaho ea Khoebo

 

 

pad-mounted-transformers-prepared-for-project-delivery

 

Meaho ea khoebo e hloka litharollo tsa motlakase tse bolokehileng, tse sebetsang hantle, tse kopaneng, le tse sa bonahaleng. Litlhoko tsena li bontša ka kotloloho lintlha tsa bohlokoa tsa tekheniki bakeng sa li-transformer tsa khoebo-tse kentsoeng, ho kenyeletsoa ho tsamaellana ha motlakase, ho sebetsa hantle, taolo ea lerata, le ho ipapisa le polokeho. Li-transformer tsa SCOTECH-mohato oa boraro-li entsoe ho nahanoa ka litlhoko tsena, li fana ka ts'ireletseho e nepahetseng, ts'ebetso, le botle ba liofisi, lipetlele, likhampase, le{5}}lintlafatso tsa ts'ebeliso e fapaneng.


Polokeho{{0}Moetso o Tsepamisitsoeng
Ka litheminale tse shoeleng{{0}ka pele tse phahameng-le ts'ireletso e kopantsoeng joalo ka lintho tse tšoarang setsoe le ho lemoha liphoso tsa ka hare (IFD), li-transformer tsa SCOTECH li fokotsa ho pepeseha likarolo tse phelang le ho matlafatsa polokeho ea basebetsi. Moralo ona o ts'ehetsa ho tsamaellana le maemo a ANSI/IEEE le litlhokahalo tsa lethathamo la UL/CUL tse boletsoeng bakeng sa meaho ea khoebo.


Compact and Space{0}}E sebetsa hantle
Libaka tse koaletsoeng li etselitsoe libaka tsa khoebo tse thata, tse fanang ka sebaka se makhethe, se sa tsitsang, ha ho ntse ho le bonolo ho kenya tšebetsong{0}}maemo. Sena se thusa ho boloka litsi tse hlokahalang ntle le ho nka sebaka sa bohlokoa sa kantle.


E tenyetseha ebile e ka Tšepahala
Meralo ea li-radial kapa loop feed ea fumaneha, 'me li-dual-voltage switching li lumella transformer ho ikamahanya le maemo ha boima ba mohaho bo ntse bo fetoha ha nako e ntse e ea. Likhetho ka bobeli-le mekhahlelo e meraro-li fumaneha ho pholletsa le mefuta e mengata ea kVA ho tsamaisana hantle le motlakase oa litšebeletso le matla.


E ntlafalitsoe bakeng sa Matla a Khoebo
Litlhophiso tse tloaelehileng tsa Delta-Wye li tsamaisana le lits'ebetso tsa kabo ea meaho e sebelisoang haholo, e nolofatsang kopanyo le lisebelisoa tse tlase. Sena se tsamaisana le li-voltages tse tloaelehileng tsa khoebo tse kang 208Y/120 V le 480Y/277 V.


Lerata le Tlase le Tlhokomelo e Nyenyane
Pholiso ea ONAN(F) e boloka ts'ebetso e khutsitse 'me e fokotsa litlhoko tsa tlhokomelo-e loketseng liofisi, lipetlele, le libaka tse ling tse bang lerata{1}}. Moralo o ntlafalitsoeng oa mantlha le tanka o thusa ho boloka maemo a molumo ka har'a meeli e tloaelehileng ea khoebo.


Boleng ba Boenjiniere boo U ka bo Tšepang
• E hahiloe ho latela maemo a machaba bakeng sa ts'ebetso le matla a matla
• Ka ho feletseng customizable ka gagamalo, kVA, le kampeng dikgetho
• Mohaho o tšoarellang,{0}}oa boemo ba leholimo{0}}ka ts'ebeletso ea ka ntle ea nako e telele-
• Phihlelo e netefalitsoeng ea ho fana ka li-transformer bakeng sa merero ea khoebo lefatšeng ka bophara
• E entsoe ka likarolo tse tloaelehileng tsa tlhokomelo ho tšehetsa bophelo bo bolelele ba tšebeletso libakeng tsa khoebo
Ka SCOTECH, u fumana ts'epahalo ea tekheniki, maemo a projeke a feto-fetohang, le ts'epo ea nako e telele-ea ts'ebetso. Setsi se seng le se seng se etselitsoe ho fihlela litlhoko tsa motlakase le tsa tikoloho tse boletsoeng bakeng sa lits'ebetso tsa sejoale-joale tsa meaho ea khoebo.

 

 

Referense ea Morero oa Kaho ea Khoebo

 

 

Bakeng sa morero o mong oa khoebo, SCOTECH e fane ka ANSI- le UL-li-pad tse thathamisitsoeng-liphetoho tse phahamisitsoeng ho laola kabo ea motlakase ho tloha ho marang-rang ho ea ho litsamaiso tsa meaho. E kentsoe ka ntle, e fana ka motlakase o tsitsitseng, ts'ebetso e tsoelang pele, le ts'ebetso e tšepahalang, e fihlelang litekanyetso tsa sejoale-joale tsa polokeho le ts'ebetso. Ha e le hantle, sena se bolela hore mohaho o ka sebetsa hantle letsatsi le letsatsi ntle le tšitiso e fokolang.

 

6

3000 kVA Transformer-25 / 0.6 kV|Canada 2025

Naha: Canada 2025
Matla: 3000 kVA
Matla: 25-0.6 / 0.347 kV
Tšobotsi: ka thermometer ea oli e holimo
Bala haholoanyane
7

3000 kVA Pad Mounted Transformer-25/0.6 kV|Canada 2025

Naha: Canada 2025
Matla: 3000 kVA
Matla: 25GrdY/14.434-0.6Y/0.347kV
Tšobotsi: ka thermometer ea oli e holimo
Bala haholoanyane
8

3000 kVA Pad Transformers-23 / 0.38 kV|Salvador 2025

Naha: Salvador 2025
Matla: 3000 kVA
Matla: 23/0.38 kV
Tšobotsi: e nang le matsoelintsoeke a koporo
Bala haholoanyane
9

2500 kVA Three Phase Pad Mounted Transformers-25/0.6 kV|Canada 2025

Naha ea thomello: Canada 2025
Matla: 2500kVA
Matla: 25kV-600Y/347V
Bala haholoanyane
10

4390 KVA Transformer Pad Mount-24/0.69 KV|Jamaica 2025

Naha: Jamaica 2025
Matla: 4390 kVA
Matla: 23.9GrdY/13.8-0.69D kV
Tšobotsi: e nang le thebe ea fatše
Bala haholoanyane
11

2500 kVA Pad Mounted Distribution Transformers-25/0.6 kV|Canada 2024

Naha: Canada 2024
Matla: 2500kVA
Matla: 25/0.6kV
Sebopeho: e nang le fuse ea ELSP
Bala haholoanyane
12

2500 kVA Padmounted Transformers-24.94 / 0.6 kV|Canada 2024

Naha: Canada 2024
Matla: 2500 kVA
Matla: 24.94/0.6kV
Sebopeho: e nang le fuse ea ELSP
Bala haholoanyane
13

2500 kVA Pad Mounted Transformer-13.2/0.48 kV|Canada 2024

Naha: Canada 2024
Matla: 2500kVA
Matla: 13.2/0.48kV
Sebopeho: le IFD
Bala haholoanyane

 

 

Likopo tse Amanang

 

 

Ka ntle ho merero ea meaho ea khoebo, SCOTECH pad-li-transformer tse palamisitsoeng hangata li sebelisoa libakeng tse fapaneng tsa kabo ea motlakase, ho kenyeletsoa:

Lisebelisoa tsena kaofela li hloka ts'epo e phahameng, polokeho e matlafalitsoeng, le ts'ebetso e tšoarellang ea kantle.

 

 

Qetello

 

 

Li-transformer tse kentsoeng ka pad ke karolo ea bohlokoa ea meaho ea sejoale-joale ea meaho ea khoebo. Moralo oa bona o bolokehileng, ts'ebetso e nepahetseng, le ho ikamahanya le maemo li etsa hore e be tse loketseng bakeng sa ho fana ka matla a tšepahalang lits'ebetsong tsa kabo ea ka tlas'a lefatše. Ka SCOTECH ea boleng bo phahameng-, litekanyetso-litharollo tse ikamahanyang le maemo, merero ea kaho ea khoebo e ka fihlela kabo ea motlakase e tšepahalang le boleng ba ts'ebetso ea nako e telele-.
 

 