1000 KVA Distribution Pad Mount Transformer-12.47/0.48 KV|USA 2025

1000 KVA Distribution Pad Mount Transformer-12.47/0.48 KV|USA 2025

Naha ea thomello: Amerika 2025
Matla: 1000kVA
Matla: 12.47/ 0.48 KV
Sebopeho: FR3 Oil & DOE e sebetsa hantle
Romela Inquiry

Jiangshan Scotech Electrical Co., Ltd ke e 'ngoe ea baetsi le barekisi ba tšepahalang ba 1000 kva distribution pad mount transformer{6}}12.47/0.48 kv|USA 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

 

1000 kva distribution pad mount transformer-front-door-open

E ka tšeptjoang,{0}}pad e sebetsang hantle-pad pad mount transformer, e etselitsoeng mokhoa o bolokehileng, o tenyetsehang, le o tšoarellang-ho{3}}kabo ea motlakase o tlase.

 

 

01 Kakaretso

1.1 Semelo sa Morero le Likarolo tsa Bohlokoa

Ka 2025, morero o moholo oa meaho ea motlakase oa Amerika o ne o hloka ho kengoa a1000 kVA three{1}}phase distribution pad mount transformerho fana ka phetolo e tsitsitseng, e ts'epahalang bakeng sa likhoele tsa khoebo le tsa indasteri tse tlase-matla a motlakase. Yuniti ena e sebetsa 'moho le marang-rang a mahareng-'me e netefatsa hore e tsamaellana le lisebelisoa tse teng, e leng se etsang hore e be tharollo e nepahetseng bakeng sa phetoho ea motlakase sebakeng sa heno.

Likarolo tsa Bohlokoa:

• Bokhoni ba phepelo ea Loop: e lumella ho hokahanngoa ho marang-rang a kabo ea selikalikoe, ho ntlafatsa ts'ebetso ea matla le ho fana ka katoloso e feto-fetohang ea marang-rang bakeng sa transformer pad mount transformer.
• Ho latela melao e sebetsang hantle ya eneji ya DOE: ho fokotsa ditahlehelo tsa tshebetso, ho fokotsa ditjeho tsa motlakase bophelong bohle ba transfoma.
• FR3 natural ester insulating fluid: e ka senyehang, e ka senyehang,{1}}insulation point point, ho lelefatsa bophelo ba ts'ebeletso le ho matlafatsa polokeho ea tikoloho.
• Sebaka sa nako e telele se koahetsoeng ka phofo e tšoeu (RAL 9003): ho hanyetsa ho bola, tšireletso ea UV, le ponahalo e hloekileng ea ka ntle bakeng sa lisebelisoa tsa ka ntle tsa pad mount transformer.
 

 

 

1.2 Tlhaloso ea Setsebi

1000kVA pad ea mekhahlelo e meraro e kentsoeng li-transformer le leqephe la data

E fetisetsoa ho
Amerika
Selemo
2025
Mofuta
Transformer ea mekhahlelo e meraro
Standard
IEEE Std C57.12.34-2022
Rated Power
1000KVA
Khafetsa
60HZ
Fepa
Loop
Pele
E shoeleng
Mokhahlelo
boraro
Mofuta oa ho Pholisa
KNAN
Mokelikeli o thibelang metsi
Oli ea FR3
Voltage ea mantlha
12.47D
Motlakase oa bobeli
0.48Y/0.277kV
Sehlopha sa Vector
Dyn1
Lintho Tse Hlahang
Aluminium
Tšitiso
5.75%
Katleho
DOE
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
1.3 kW
Ho Lahleheloa ke Moroalo
6.94 kW
Lisebelisoa
Tlhophiso e Tloaelehileng

 

1.3 Litšoantšo

1000kVA pad ea mekhahlelo e meraro e kentsoeng setšoantšo sa transformer le nameplate

1000 kva distribution pad mount transformer-outline-drawing 1000 kva distribution pad mount transformer-nameplate

 

 

02 Likarolo tsa Moralo le Sebopeho

2.1 Boraro-Mohato oa Boraro-Limb Core

1000 kva distribution pad mount transformer-steel-core
1000 kva distribution pad mount transformer-amorphous-core

Transfoma e na le-mehato e meraro,-a mararo{1}}maoto a khoheli a ahiloeng ho tloha{2}}mahlaku a batang a phahameng-a kolokisitsoeng-ea li-silicon steel laminations. Precision stacking e fokotsa tahlehelo ea mantlha, ho thothomela le lerata la acoustic ha o ntse o boloka matla a khoheli a tsitsitseng. Sebopeho sena se netefatsa ts'epahalo ea nako e telele- bakeng sa distribuerar pad Mount ts'ebetsong e tsoelang pele-ea motlakase.

 

2.2 Aluminium Winding System

1000 kva distribution pad mount transformer-winding
1000 kva distribution pad mount transformer-transformer-windings

Matsoho a aluminium a nang le-mohatsela o phahameng oa mocheso a fana ka tekanyo e nepahetseng ea ho sebetsa, matla, le boima bakeng sa meralo ea compact pad{1}}ea meralo ea transformer. Likhoele li kopantsoe ka hloko 'me li matlafatsoa ka mokhoa oa mochini, ho ntlafatsa ts'epahalo ea ho koala le ho matlafatsa matla a ho hanyetsa-nakong ea maemo a sa tloaelehang.

 

2.3 FR3 Insulation and Cooling System

1000 kva distribution pad mount transformer-oil-tank

Transformer ena e sebelisa FR3 ea tlhaho ester insulating fluid, e leng biodegradable, e nang le sebaka se phahameng sa mollo, 'me e fana ka mamello e phahameng ea mongobo ha e bapisoa le oli ea diminerale. Mokhoa oa ho pholile oa KNAN o kopanya ho potoloha ha oli ea tlhaho le moea oa tlhaho oa moea, ho boloka mocheso o tsitsitseng oa ts'ebetso ntle le lisebelisoa tse ling tse pholileng, ho etsa bonnete ba hore mochine oa ho tsamaisa pad mount o sebetsa hantle.

 

2.4 Pad-Sebaka se Behiloeng

Thepa{{0}e kampetsoeng e sebelisa moetso o shoeleng{1}o ka pele ho sireletsa basebetsi hore ba se ke ba kopana le likarolo tse matla. Khabinete e kopaneng ea kantle e na le likarolo tsa transformer, lisebelisoa tsa switching, le lisebelisoa tsa ts'ireletso ka har'a sebopeho se bolokehileng se loketseng ts'ebeliso kapa ts'ebetso ea indasteri.

1000-kva-distribution-pad-mounted-transformer-lead-handling-active-part

 

 

03 Likarolo tsa Ts'ebetso le Ts'ireletso

1000-kva-distribution-pad-mounted-transformer-Standard Monitoring & Protection Accessories

Transfer pad Mount transformer e kenyelletsa karolo e felletseng ea ts'ireletso le likarolo tsa ho beha leihlo ho netefatsa ts'ebetso e bolokehileng:

• Moralo o shoeleng- oa tšireletso
• Thebe e thehiloeng ea electrostatic
• Tšireletso ea fuse
• Four-switch load break break
• Tekanyo ea boemo ba oli le ho hlahloba mocheso

 

 

04 Ho paka le ho Romela

4.1 Ho paka

1000 kva distribution pad mount transformer-vacuum-packaging-in- aluminum-foil-bag
1000 kva distribution pad mount transformer-export-packing

 

05 Boemo ba Kopo

Transformer ea 1000 kVA pad pad mounted pad e loketse bakeng sa:

• Mehaho ea liofisi tsa khoebo
• Likopano le lifeme tsa indasteri
• Litsi tsa data le lisebelisoa tsa IT
Moetso oa eona oa compact pad-moetso o kentsoeng, DOE e sebetsang hantle, le FR3 insulation li fana ka kabo e tšepahalang, e feto-fetohang, le e baballang tikoloho ea -motlakase oa motlakase ho ea ho{3}}motlakase o tlase. Transformer ena ea pad pad mount e tiisa matla a tsitsitseng le a tsoelang pele bakeng sa meroalo e thusang le e boima.

 

Hot Tags: 1000 kva kabo letlapa thaba transformer-12.47/0.48 kv|usa 2025, Chaena 1000 kva pad pad mount transformer-12.47/0.48 kv|USA 2025 bahlahisi, bafani ba thepa, fektheri

Romela Inquiry