1500 KVA Electrical Transformer Box-12.47/4.16 KV|USA 2025
Matla: 1500kVA
Matla: 12.47/4.16kV
Sebopeho: ka UL e thathamisitsoeng
Jiangshan Scotech Electrical Co., Ltd ke e mong oa baetsi le barekisi ba tšepahalang ka ho fetisisa ba 1500 kva electronic transformer box{6}}12.47/4.16 kv|USA 2025 naheng ea China. Ka kopo, ikutloe u lokolohile ho reka lihlahisoa tse baballang litšenyehelo tse rekisoang mona le ho fumana litšoantšo ho tsoa femeng ea rona. Ikopanye le rona bakeng sa lintlha tse ling.

Lebokose la motlakase la motlakase le tsoetseng pele le etselitsoeng ho kopana le maemo a IEEE le UL, le netefatsa hore kabo ea motlakase e sebetsa hantle ebile e bolokehile.
01 Kakaretso
1.1 Tlhaloso ea Morero
1.5 MVA (1500 kVA)tse tharo-pase ea mekhahlelo-e kentsoeng ka transformere fana ka ts'epahalo, e sebetsang-matla a boemo bo botle sebakeng se kopaneng, se thibaneng{1} E hahiloe ho kopana le IEEE Std C57.12.34-2022, DOE 2016, le litekanyetso tse thathamisitsoeng tsa UL. E fana ka tharollo e bolokehileng le e sebetsang hantle bakeng sa litsamaiso tse mahareng tsa- tsa motlakase 'me e tla le tiisetso ea lilemo tse 3 bakeng sa ts'epahalo ea nako e telele.
Transformer e na le lupu-feela ebile e shoele{1}moetso o ka pele. E fetola motlakase ho tloha ho 12.47 kV ka lehlakoreng le ka sehloohong ho ea ho 4.16 kV ka lehlakoreng la bobeli le sehlopha sa li-vector Dyn1. Setupo sena se sebetsa hantle bakeng sa mefuta e mengata ea marang-rang. E na le maemo a mahlano a ho theoha-ea lipompo tsa potoloho (14.4 kV, 13.8 kV, 13.2 kV, 12.47 kV, 12.0 kV) ho lokisa motlakase kamoo ho hlokahalang sebakeng. E sebelisa pholiso ea ONAN le ho kenya oli ea liminerale. Ho phahama ha mocheso ke likhato tse 65. Likarolo tsena li boloka transformer e tsitsitse mme e lelefatsa bophelo ba eona ba ts'ebeletso.
Maqhubu a eona a aluminium a fana ka ho leka-lekana ha nako e telele le ho sebetsa hantle ha litšenyehelo, ha impedance ea 5.75% e tšehetsa tsamaiso ea liphoso e tšepahalang. E lekoa bakeng sa tahlehelo ea DOE 2016-ha ho{4}tahlehelo ea mojaro ea 1,545 W le tahlehelo ea thepa ea 10,540 W{9}moetso o kopana le lipehelo tsa tšebetso-e sebetsang hantle le ho fokotsa litšenyehelo tsa ts'ebetso. Lisebelisoa tse tloaelehileng li kenyelletsa fuse ea bayonet e nang le lihokelo tsa ho itšehla thajana le likarolo tse tharo-, tse peli-li-position load break switch.
Likarolo tsena li etsa hore tšireletso e be bonolo le hore ts'ebetso e bolokehe.
Transformer e kopane, e ka tšeptjoa ebile e bonolo ho e hlokomela. Ke khetho e ntle bakeng sa lits'ebetso tsa phepelo ea lisebelisoa, libaka tsa matla tse nchafalitsoeng, lits'ebeletso tsa indasteri, le marang-rang a motlakase oa meaho Amerika (ho tsamaisoa ha 2025).
1.2 Tlhaloso ea Setsebi
Tlhaloso ea lebokose la motlakase oa 1500 KVA le leqephe la data
|
E fetisetsoa ho
Amerika
|
|
Selemo
2025
|
|
Mofuta
Transformer ea mekhahlelo e meraro
|
|
Standard
IEEE Std C57.12.34-2022
|
|
Rated Power
1500KVA
|
|
Khafetsa
60HZ
|
|
Fepa
Loop
|
|
Pele
E shoeleng
|
|
Mokhahlelo
Boraro
|
|
Mofuta oa ho Pholisa
ONA
|
|
Mokelikeli o thibelang metsi
Oli ea Liminerale
|
|
Voltage ea mantlha
12.47 kV
|
|
Motlakase oa bobeli
4.16 kV
|
|
Sehlopha sa Vector
Dyn1
|
|
Lintho Tse Hlahang
Aluminium
|
|
Tšitiso
5.75%
|
|
Sebetsa le Tahlehelo Standard
DOE 2016
|
|
Tlanya Changer
NLTC
|
|
Tlanya Range
14400, 13800, 13200, 12470, 12000
|
|
Ha ho Tahlehelo ea Mojaro
1545 W
|
|
Ho Lahleheloa ke Moroalo
10540 W
|
|
Lisebelisoa
Bayonet w/ ISO Links, Three piece 2 position Load Break Switch
|
1.3 Litšoantšo
1500 KVA sets'oants'o sa lebokose la motlakase oa motlakase oa setšoantšo le boholo

02 Tlhahiso
2.1 Ntlha ea bohlokoa

The 1500 KVA electrical transformer box core e na le-maoto a mararo, mohato{2}}moetso o entsoeng ka lap mitered. E entsoe ka tšepe ea lijo-thollo-e tšekaletseng, e batang{5}}e kolobisitsoeng ka silicon. Lamination e 'ngoe le e' ngoe e khaotsoe ka mokhoa o nepahetseng 'me ha e na li-burrs. Sena se thusa ho theola tahlehelo ea mantlha le ho fokotsa lerata. Li-lamination li phuthetsoe 'me li tlameletsoe ka thata ho qoba likheo tsa moea. Sena se ntlafatsa ts'ebetso ea makenete mme se boloka transformer e sebetsa hantle ebile e tšepahala.
2.2 Ho tsubella


Transformer e na le terata-e phahameng maqeba a phahameng-likhoele tsa motlakase oa mantlha le lakane-likhoele tsa maqeba tsa bobeli. Moralo ona o fokotsa khatello ea maikutlo e bakoang ke li-circuits tse khutšoane mme o lumella kabo e leka-lekaneng ea matla a khoheli ho pholletsa le likhokahano tsa pompo. Likhoele li entsoe ka metjhini e tsoelipanang hantle{{5}e nepahetseng e netefatsang tsitsipano e sa fetoheng le ho beoa ha conductor ka nepo, ho fa transformer e matla e khutsufalitsoeng{6}}e thibang potoloho le ho sebetsa hantle haholo.
2.3 Tanka
Tanka ea transformer e entsoe ka tšepe e bonolo. E matla 'me ho bonolo ho e tšoara, ho e kenya le ho e hlokomela. Tanka e na le sekoahelo se tiisitsoeng sa bolt ho sireletsa mokelikeli o sireletsang le likarolo tse ka hare. Tšepe e nepahetse-e sehiloe, ea chesa-ea phuthoa, ea tšeloa, 'me e tlotsoe ka oli. The welding e etsa bonnete ba hore tanka e tšoarella ebile e ka tšeptjoa.

2.4 Kopano ea ho Qetela

Thepad{{0}sefetoleli se ka holimocore le coil assembly e tlamiloe ka litšepe tse boima ho thibela likhoele tse khutlonnetsepa hore li se kobehe ka nako e khutšoane-ea potoloho. Lipoleiti li tlanngoe ka thata ka li-presses ebe lia chesetsoa kapa li bouheloa ho etsa sebopeho se tiileng. Kopano e kopana kapa e feta ditekanyetso tsa ANSI le IEEE tse khutšoane- tsa potoloho. Moralo o thata o etsa hore litšitiso li be nyane, joalo ka selika-likoe-likhoele tsa maqeba.
03 Likarolo Tse Ka sehloohong






04 Ho etsa liteko


05 Ho paka le ho tsamaisa
5.1 Ho paka


5.2 Ho tsamaisa thepa


Hot Tags: lebokose la motlakase oa motlakase, moetsi, mofani oa thepa, theko, litšenyehelo
You Might Also Like
1500 kVA Ansi C57 12.34 Transformer-23/0.44 kV|Salva...
2500 kVA Transformer-0.6 / 13.8 kV|USA 2025
250 KVA Small Pad Mounted Transformer-13.8/0.22 KV|G...
500 KVA Green Electric Transformer Box-23.9/0.22 KV|...
4390 KVA Transformer Pad Mount-24/0.69 KV|Jamaica 2025
1000 KVA Custom Loop Feed Motlakase Pad Mounted Tran...