Scotech e phethela ka katleho ho amoheloa ha oli ea 22mva 132/11)}
Aug 26, 2025
Siea molaetsa

Ho tloha ho la 26 Phato ho ea ho la 27 Phato 20-255, Scotech e ile ea amohela moifong oa eona oa Afrika Boroa mme o ile a phelisa oli ea 'mele oa ma-Afrika Bohlaba. Ho amoheloa hona ka tieo ho latela mokhoa o nepahetseng oa liteko, o bakang tlhahlobo e phethahetseng ea matšoao a fapaneng a sethala. Qetellong, phetoho e fumanoeng e phahameng ho moreki e tsoa ho moreki ea nang le tšebelisano e ntle ea tšebelisano e 'meli lipakeng tsa sehlahisoa sa matla a Afrika Boroa.
Oli - Matla a qotsitsoeng a fetisoa nakong ena a amohetse nako ena ke lisebelisoa tsa k'homphieutha ho fihlela litlhoko tsa tsamaiso ea matla a Afrika Boroa. Ka mohlala o tšoailoeng ka ho hlaka 20/22 mva 132 / 11kv le konteraka ea jsskt25080, e kopana ka botlalo litlhoko tsa lichelete tsa moreki le bokhoni. Sesebelisoa sena sa Transformer se na le bokhoni ba ho feto-fetoha ha maemo: Tlas'a Onan Ha o fetohela ho ONaf (moea oa tlhaho oa oli o qobelloang) Mokhoa oa ho futhumatsa, bokhoni bo ka eketseha ho 22 Mva. E ka ikamahanya le liphetoho ho mojaro o fapaneng le linako tsa Afrika Boroa, o fana ka tšehetso e tšepahalang ea ts'ebetso e tsitsitseng ea ts'ebetso ea boea ba lefatše. Ho sa le joalo, transformer o amohela sehlopha sa Vnyn0 sa Vnyn0, 'me o sebelisa ho nepahala le ho kopana le ho kopana hape ka boleng ba motlakase bakeng sa boleng ba matla.
Nakong ea kamohelo, scoetetch le moreki oa Afrika Boroa o ile a latela melao ea liteko tsa morao-rao e boletsoeng ka mokhoa oa tlhahlobo, likarolo tsa motlakase le tšebetso ea motlakase. Teko e 'ngoe le e' ngoe e lumellana ka kotloloho le letoto la machabeng 60076 ea litekanyetso tsa machabeng (ho kenyeletsoa IEC 60076-3, ETC 60076-3, Etc.), joalo-nete

Ka karolong ea tlhahlobo ea tlhahlobo ea tlhahlobo ea liteko, tse peli tse shebaneng le ho khanna liteko tse 'maloa tsa mantlha. Har'a bona, tekanyo ea likhase tse qhibilihileng ka mokelikeli o mong le o mong o ikemetseng oa oli (ntle le komporo ea sejo se ikemetseng) e ne e le bohlokoa haholo. Sekhethesi sa khase li ile tsa etsoa ho sethaleng sa sethala pele le kamora tlhahlobo. Liphetho tse bonts'ang hore hydrogen (H₂) e ne e le <10 ppm, the acetylene (C₂h₂) e ne e le tlase ho 60. 1%, mme oli e bonahala pepeneneng ntle le lintho tse emisitsoeng kapa litšila tsa mochini. Liphetho tsena li kopane le litekanyetso tse amehang ka botlalo ka litekanyetso tsa tlhahlobo ea liteko tsa liteko tse ncha tsa liteko, tse bontšang hore oli ena e mecha e ile ea tšoaneleha ebile e na le phoso ea liphoso. Ho feta moo, tekanyo ea ho hlohlelletsa ho hongata pakeng tsa meea le lefats'e e ile ea khannoa ka meea e meraro ea 50001 e kholo ho feta kapa e lekanang le 1.5. Ka tlhahlobo ea lipontšo tsa lipontšo tsa dikarolo tsa mantlha tsa koluoa, poloko e sirelelitsoeng e ne e le kholo ea ts'ebeliso ea lisebelisoa.


Ho latela netefatso ea motlakase ea motlakase, tekanyo ea Voltage ea Voltage Che, Hlahloba CHEVE e koahetse maemo ohle a tala. Volta - ho fetoloa voltage Sehlopha sa Nakector se ile sa kopana le tumellano ea Zyn0, e netefatsa ho nepahala ha voltage ea Transpherimer Mo khuts'oane oa {{{{{{{}} Boleng ba ho hlomamisetsoa ha tapping e kholo (ho 75 degree) ho tsoa ho voltage e tlase ho isa ho 180%, mme tahlehelo ea moroalo e ne e le tlase kapa e lekanang le 120 kw. The Che- Marolla ho tahleha le tekanyo ea hajoale e ne e tšoaretsoe ho 90%, 100%, le 110% ea lithaba tse sa ts'oereng. Li-voltage tse 100% tse kenngoeng All parameters met the design standards, demonstrating the transformer's excellent energy conversion efficiency and energy-saving performance. Ho feta moo, liteko tse kang cheke ea karolelano ea karolelano ea -}} mafelong a ho hanyetsa khafetsa ho ne ho phetheloa ka katleho. Karolelano ea tikolohong ea hona joale e ile ea hanyetsa litlhokahalo tsa litšoantšo, le ho hanela le ho hanyetsa ka lehlakoreng le leng ho ne ho hanyetsa mela le <2% pakeng tsa mela le <2% pakeng tsa mela le <2% pakeng tsa mela le <2% pakeng tsa mela le <2% pakeng tsa mela le <2% pakeng tsa mela le <2% pakeng tsa mela le. Liphetho tsena li netefalitsoe ka botlalo botšepehi le botsitso ba tsamaiso ea motlakase oa lisebelisoa.


Ka mochini o nang le mochini le ho voltage mabapi le liteko tsa ts'ebetso, the {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0 {0-}}}} Potoloho e 1 e ile ea phethoa ha voltage e sebetsang e fokotsehile ho 85% ea boleng ba eona bo lekantsoeng; Potoloho e le 1 e ile ea phethoa ha se fetoletsoeng e ne e fa matlafatsoa khafetsa le mocheso ka tlase ho che- maemo; Mesebetsi ea phetoho ea 10 Tlanya e ile ea phethoa ka sekhukhu e le 'ngoe e boreleli- Ha ho na liphoso tse etsahetseng nakong ea ts'ebetso eohle, li paka tšebetso e ka tšeptjoang ea ho -}}}}}}}}}}}}}}}}}}}}}}}}} Bakeng sa {12 [12]}} Phuputsong ea Voltage ea Project, Line Terminal Ac Conthage Teko ea Voltage, le Tekanyo ea Voltage (PD) Tekanyo ea Pentage ea Teko. Ka nako e le 'ngoe { Boemo ba PD bo ka morao bo ne bo le tlase kapa bo lekanang le PC, ba netefatsa bokhoni ba ho emisa litšusumetso tsa letlalo. Qetellong, tlhahlobo e tiileng ea khatello, khatello ea 30 kpa e ile ea sebelisoa le ho hlokomeloa ka lihora tse 24, netefatsa hore likotsi tsa oli li tsoa nakong ea ts'ebetso ea oli.

Ho pholletsa le tse peli {0 0}} Sehlekehleke sa Liteko sa Afrika Boroa mme se pataganya haholo sehlopha sa seqoso sa Scoetese. Moemeli oa moreki o ile a re Scotech ha a phenyeko feela liteko tsa machabeng le litlhokahalo tsa konteraka ea boleng bo phahameng ka lintlha. Transformer o ile a lumela ka nako ena e kopana le litlhokahalo tsa gridi ea a Afrika Boroa, 'me li lebelletse tšebelisano ea thepa ea lisebelisoa tse ngata nakong e tlang.
Ha khoebo e bua ka R & D le tlhahiso ea oli- Melao ea Matla a Actimer Katleho ea kamohelo ena ha se taba feela ea boleng ba k'hamphani empa le molemong oa bohlokoa bakeng sa k'hamphani ea motlakase oa Afrika. Nakong e tlang, Scotech e tla tsoela pele ho tebisa boteng ba lisebelisoa tsa lisebelisoa, lokisa ts'ebetso ea sehlahisoa sa lichelete le mekhoa ea liteko.