GIS ke eng?

 

 

Gas Insulated Switchgear Lebitso la eona le felletseng ke khase e anngoeng ke khase. Khase e tsitsipano mona e bua ka sebabole ho sesa SULFUR HEXAFLuAFL. Strickgear ke semumu sa bosholu ba litsuoatso tsa potoloho, li-discor li felisi, li-transches, bahlaseli ba li-buss Lisebelisoa kapa likarolo tsena kaofela li kenngoa ka lehare la tšepe, 'me li tletse ha SF6 khase khatisong e itseng, kahoo e bitsoa SF6 ka botlalo. Ka hona, GIS ke ho kopanya li-v Vis- Likarolo tsa Voltage ka sistimi ea motlakase ea SF6.

 

Litšobotsi tsa SF6

gas sf6

SF6 ke khase e hlophisitsoeng ka methapo e khethiloeng e tsoaloa Fora. Khase e hloekileng ea SF6 e se nang 'mala,

Ha e na monko o se nang letho Ke khase ea kelello. Bomoko ba khase ke boima ba moea.

SF6 GOS e na le matla a ho etsa joalo a oli ea transformer hodima oli ea ts'ebeliso ea 0.29 m Hajoale ke khase e sebelisoang ka ho fetisisa ea motlakase.

 

Papiso lipakeng tsa AIS le GIS

air insulated switchgear gas insulated switchgear
Air switzergreaar Khase e Akaretsang

 

1. Sebaka sa fatše

Floor Space of Gas Insulated Switchgear GIS, sephutheloana sa tšepe ka botlalo se nang le sebopeho se nang le komporo, li lula li-10% feela tsa sebaka sa fatše sa 220kv feela Ke ka hona Gis ke khetho ea pele libakeng tseo tlhoko ea naha e phahameng haholo, ho fumaneha ha mobu hohle haholo. Ho joalo, ha ho bolele hore naha ke eona feela mokhoa oa ho khetha GIS. Ho na le lintlha tse ling tse ngata, 'me hona ke e' ngoe ea tsona.

 

2. Bongata

altitude

Kamano lipakeng tsa bophahamo le matla a lijo:

Ha setoriti se nyoloha, khatello ea sepakapathe ea sepakapaka e oela bohlokoa haholo, e fella ka ho fella ka ho fokotseha ha letsoalo la moea. Moea o fetoha "tšesaane". Matla a sebetsang a moea (bokhoni ba eona ba ho hanela tlhekefetso ea motlakase le ho thibela ho ikarola ho latela letsoalo la eona. Moea o nang le letsoalo le tlase (bophahamo bo phahameng) bo na le libaka tse kholo tsa molek'hule le litsela tse telele tsa mahala. Sena se nolofalletsa li-elektrone tšimong ea motlakase ebe ho fumana matla a lekaneng ho tobana le limolek'hule tse ling, ho etsa hore ho be bonolo ho liha kaselapotla (arcne). Ka hona, nthong e ts'oanang ea [Volilage ea hau

Ha scitvar e kentsoe bophahamong bo phahameng ba motlakase,. Ke kahoo, hobane, bakeng sa moea o tloaelehileng {1]}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}} Gis e sirelelitsoe ke khase ea SF6, ho kenya ha eona e ke ke ea angoa ke bophahamo.

 

3. Ts'ireletso

safety

Mabapi le polokeho, tsohle tse phahameng -}}}}}}}}}} Ho itšireletsa thebed ea tlhaho ea electrimagnet (phello ea faradal), le haeba lisebelisoa li se matla ka kotloloho ha lisebelisoa li ke ke tsa etsahala, ho fihlella ts'ireletso ea polokeho ea ho kenella tsa polokeho. Ais o lula sebopeho se bulehileng, le {{{{3 3}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}}} Ha o sebetsa kapa o atamela ka phoso, basebetsi ba tlameha ho boloka sebaka se sireletsehileng (hangata ho feta limithara tse 'maloa). Ho na le kotsi e mpe ea ho ama thepa ea ho ama ka phoso, le litšitiso tsa ho felisoa 'meleng le litlhaloso tsa ts'ebetso li tlameha ho ts'eptjoa bakeng sa ts'ireletso.

Empa sena ha se bolele hore AIS ha a sireletsehe kapa ho se sireletsehe ho hang. Ha e le hantle, 70% ea lintho tse fapaneng lefatšeng ka bophara e entsoe ka theknoloji ea Ais. Regular cleaning of insulators, installation of bird protection devices, and de-icing equipment can also maintain safe operation.

 

4. Katoloso ea sebaka

Ha a rala taba, baenjiniere hangata ba boloka sebaka sa naha ho fihlela litlhoko tsa kholo ea moroalo. Ka moea {{1]}}} Ho tloha ka lisebelisoa tsa Ais (joalo ka li-breakersosa tsa potoloho, li-disconnector, li-bubbars, li-bubbars, haholo-holo ho kenngoa ka meea ea moea le ho phomola pakeng tsa e mong. Ho eketsa li-bayshes tse ncha kapa ho holisa libethe hangata ho hloka ho kenya lisebelisoa tse ncha tse tloaelehileng sebakeng se matla sa motlakase. Ho na le boitšepo bo fokolang ka mohlala kapa moetsi oa lisebelisoa tse sa tsoa feta. Lisebelisoa tsa lihlahisoa tsa lihlahisoa tse fapaneng (ha feela li kopana le litlhoko tsa parametara) hangata li ka kenella habonolo liteisheneng tse teng kapa li matha ka tsela e itseng.

 

Leha ho le joalo, bakeng sa khase-}}}}}}}}}}}}}}}}}}}}}}}}}}}} Sena ke hobane Gis e hokahanya haholo- litšoantšo tsa voltage le ho li tiisa ka matlo a tšepe a se nang thuso (joalo ka SF6). Expansion usually means that new, fully matched gas-sealed spacer modules must be added. Li-majule tsena li lokela ho lumellana hantle le lisebelisoa tse teng ho latela boholo, mohokahanyi le lisebelisoa tsa mantlha (boqapi ba matlo le ho lekola lits'ebetso tsa matlo le ho lekola lits'ebetso tsa matlo le ho beha leihlo. Ntho ena e amanang le eona e etsa hore ho be teng ho sebelisa libui tse ikhethang tsa moetsi oa mohlala, kapa esita le letoto le le leng le ho boloka tšebetso ea tlhaho le tsamaiso ea maikutlo. Ka hona, moralo oa keketlo oa GIS o itšetleha haholo ka khetho ea lisebelisoa tsa pele le tse telele tsa moetsi.

 

5. Tšireletso ea tikoloho

 

environmental protection Ho latela ts'ireletso ea tikoloho, Ais le Gis ba na le melemo le mathata a bona. Ais o sebelisa likhohlano tsa moea mme ha li kenyeletse tšebeliso ea khase ea greenhouse ea greenhouse. Ha ho bapisoa le khase ea SF₆ e sebelisitsoeng Gis, e na le tšusumetso e fokolang tikolohong, haholo ha e laole phello ea sethopo. Ka nako e ts'oanang, sebopeho sa Ais se bonolo haholo, se etsang hore ho be bonolo ho khelosa le ho itlhakisetsa le ho ikhula ha o tlohela mosebetsi, 'me o na le moroalo o bobebe. Leha ho le joalo, GIS ke tikoloho e ntle haholo nakong ea kaho le ts'ebetso. E nka sebaka se nyane 'me e loketse naha ea lefatše e loketseng libaka tse arohaneng tse kang litoropo. E na le nako e khuts'oane ea kaho 'me e hlahisa lerole le fokolang. Sebopeho se koetsoeng hantle se fokotsa lerata la ho sebetsa hantle ebile ha a sitisoa ke tikoloho e potileng. Ka hona, ka kakaretso, Ais ke tikoloho e ntle haholo ho fokotsa sebopeho sa khase ea setho sa botumo, ha Gis e etsa hantle ka ho boloka chelete, ho fokotsa tšusumetso ea mobu, le tšusumetso ea mobu. Ka nts'etsopele ea theknoloji e mecha ea tikoloho ea tikoloho e botsoalle, ts'ebetso ea tikoloho ea Gis e lebelletsoe ho tsoela pele ho ntlafatsa nakong e tlang.

 

 

6. Litšenyehelo

Lits'enyehelo tsa tlhahiso ea lisebelisoa tsa Ais li ka bang 30% {4} {4} {4% ea Gis, e nang le monyetla oa theko ea mantlha. Naha e theko e boima e hlaheletseng: sebaka se lekaneng sa polokeho ea motlakase o hloka ho bolokoa bakeng sa basolli ba pepeneneng, ho fella ka sebaka se seholo. Libakeng tsa litoropo kapa boleng ba boleng bo holimo, chelete ea ho fumana chelete e ka feta ho tsetela lisebelisoa. Tafole e latelang ke papiso ea tsetelo ea pele, ts'ebetso le litšenyehelo tsa ho lokisa le litša tse ngata tsa bophelo tsa Ais le Gis.

Bophahamo Ais GIS
Tsetelo ea pele Lisebelisoa tse tlase li theko (hoo e ka bang 30% -50% ea GIS) Lits'enyehelo tse phahameng tsa mobu Lisebelisoa tse phahameng tsa lisebelisoa (ho kenyeletsoa khase ea khase e tiisitsoeng ea khase / sf₆ khase) Lands e boloka chelete ea 50-70%
Litsenyehelo tsa Ts'ebetso le Tlhokomelo Ho hloekisoa khafetsa ha li-instrators Anti {0 0}} Flahover Clashoss Clashover Coating / De {{{{{{{{{{{{{{}}}}}}}- Hasal, Tlhokomelo -}}}
Mesebetsi e felletseng ea bophelo Theko e tlase ea theknoloji, tokiso e bonolo empa e tsoelapele Ho tsetela pele ho pele, le litšenyehelo tsa ts'ebetso li ka fokotsoa ke 40% + nakong ea lilemo tse 20

 

 