862 KVA Unit Substation-13.8/0.48 kV|USA 2025

862 KVA Unit Substation-13.8/0.48 kV|USA 2025

Naha: Amerika 2025
Bokhoni: 750/862 kVA
Matla: 13.8-0.48/0.277kV
Tšobotsi: ka oli ea FR3
Romela Inquiry

 

 

image001

Smart Power, Poloko e Phahameng. Li-Unit Substation Transformers tsa rona.

 

 

01 Kakaretso

1.1 Tlhaloso ea Morero

750/862 kVA unit substation transformer e ile ea isoa Canada ka 2025. Matla a rekiloeng a transformer ke 750/862 kVA e nang le mohatsela oa KNAN/KNAF. Motlakase oa mantlha ke 13.8 kV e nang le ± 2 * 2.5% tapping range (NLTC), motlakase oa bobeli ke 0.48 / 0.277 kV, ba thehile sehlopha sa vector sa Dyn1.

E etselitsoe ho sebetsa hantle le ho ts'epahala, transformer ena ea 750/862 kVA yuniti e fana ka tharollo e felletseng ea motlakase e etselitsoeng litlhoko tse boima tsa khoebo le indasteri. E na le FR3® ea tlhaho ea ester fluid bakeng sa ts'ireletso e matlafalitsoeng ea mollo le bophelo bo atolositsoeng ba ho kenya letsoho, hammoho le ts'ebetso e ntlafalitsoeng ea mocheso (Oli e ka Holimo: 45K, Winding Avg: 50K, Hot Spot: 63K) ho netefatsa katleho le ho tšoarella tlas'a maemo a tlhōrō. Transformer e sebetsa ka thata-e theiloe molemong oa ts'ireletso e ntlafalitsoeng ea sistimi, 'me e na le lisebelisoa tse felletseng tse kopantsoeng{9}}ho kenyeletsoa CT cabinet bakeng sa metering le ts'ireletso, li-radiator tse senyehang tse nang le pholileng ea fene, mabili a etsang hore a be bonolo, ho phahama ka potlako ho thibela mathata a ka hare, le lintho tse thibelang lehalima bakeng sa ts'ireletso{10}{1}ho lokisetsa{1}ho lokisa{1} sephutheloana sa motlakase se etselitsoeng polokeho, ts'epahalo le boiketlo ba tlhokomelo.

 

 

1.2 Tlhaloso ea Setsebi

750/862 mofuta oa lintlha tsa kVA unit transformer le leqephe la data

E fetisetsoa ho
Amerika
Selemo
2025
Mofuta
Substation ea motlakase
Standard
ANSI C57.12.00
Rated Power
750/862 kVA
Khafetsa
60HZ
Mokhahlelo
3
Mofuta oa ho Pholisa
KNAN/KNAF
Voltage ea mantlha
13.8 kV
Motlakase oa bobeli
0.48/0.277 kV
Lintho Tse Hlahang
Koporo
Angular displacement
Dyn1
Tšitiso
6%
Tlanya Changer
NLTC
Tlanya Range
±2*2.5%
Ha ho Tahlehelo ea Mojaro
Ka tlase ho kapa ho lekana le 1.16kW
Ho Lahleheloa ke Moroalo
Ka tlase ho kapa ho lekana le 7.08kW

 

1.3 Litšoantšo

750/862 kVA setaele sa sefetoleli sa yuniti ea yuniti le boholo.

image003 image005

 

 

02 Tlhahiso

2.1 Ntlha ea bohlokoa

Moko oa mantlha o nepahetse-o hahiloe ka-kalo e phahameng, e batang{2}}mabele a kolokisitsoeng-ka tšepe ea silicon e omisitsoeng. Thepa ena, hammoho le moralo o tsoetseng pele oa laminated, e fokotsa tahlehelo ea matla le matla a hona joale. Kaho ea eona e matla e netefatsa maemo a tlase a lerata le matla a mochini, e fana ka tsela e tsitsitseng le e sebetsang ea makenete eo e leng ea bohlokoa ho ts'epahalo le ts'ebetso ea transformer.

 

2.2 Ho tsubella

The windings ba optimally hahiloe bakeng sa tshebetso le ho tšepahala. Matsoho a {{1}voltage a tlase a sebelisa foil-moetso oa maqeba, o fana ka matla a holimo, a tima mocheso o phahameng haholo, le bokhoni ba ho mamella{3}sekoloi se phahameng haholo. Ho e tlatselletsa, -mohatla oa motlakase o phahameng o sebelisa lesela le nepahetseng-mokhoa oa maqeba o nang le matla a matla a ho kenella ka har'a{7}, ho netefatsa phetoho e nepahetseng ea motlakase le matla a matla a dielectric. Motsoako ona o netefalitsoeng o fana ka ts'ebetso e ikhethang, botsitso le ho tšoarella.

image007

 

2.3 Tanka

image009

Tanka ke mohaho o matla, o entsoeng ka tšepe o etselitsoeng ho tšoarella le ho sebetsa. E sebetsa e le sebaka sa tšireletso bakeng sa mantlha le li-windings, e fana ka letamo le tiisitsoeng bakeng sa mokelikeli o sireletsang metsi, 'me e na le li-radiator bakeng sa ho qhala mocheso hantle. E etselitsoe ho mamella likhatello tsa tikoloho le ts'ebetso, tanka e netefatsa bots'epehi le ts'epahalo ea nako e telele ea transformer-.

 

2.4 Kopano ea ho Qetela

Kopano ea ho qetela ke kopanyo e nepahetseng ea mantlha, li-winding, tanka le lisebelisoa ho sistimi e kopaneng le e matla. Karolo ena e mahlonoko e tiisa hore likhokahano tsohle tsa motlakase tsa kahare li sirelelitsoe, meaho ea mochini e utloahala, 'me sebaka se koaletsoeng se tiisitsoe hantle. Sephetho ke -e leng teng, e itokiselitseng-ho-sebelisoa sa motlakase se fanang ka ts'ebetso e hlophisitsoeng, e tšoarellang le e ts'epahalang.

image011

 

 

03 Teko

Che.

Ntho ea Teko

Yuniti

Melao ea ho Amohela

Litekanyetso Tse Lekanyelitsoeng

Qetello

1

Litekanyo tsa ho hanyetsa

%

Sekhahla se phahameng sa ho hanyetsa ho se leka-lekane

3.19

Feta

2

Liteko tsa Karolelano

%

Phapang ea karo-karolelano ea motlakase ho theipi ea mantlha: Ka tlase ho kapa ho lekana le 0.5%

-0.05~0.01

Feta

3

Liteko tsa likamano tsa mohato-

/

Dyn1

Dyn1

Feta

4

Ha ho{{0}tahlehelo ea thepa le thabo ea hona joale

%

I0 :: fana ka boleng bo lekantsoeng

0.47

Feta

kW

P0: fana ka boleng bo lekantsoeng

0.938

/

mamello ea ho se lahleheloe ke moroalo ke +0%

/

5

Litahlehelo tsa meroalo, motlakase oa impedance, tahlehelo e felletseng le katleho

/

T:85 likhato

mamello ea ho iphelisa ke +7.5%

mamello ea tahlehelo ea boima kaofela ke +0%

/

Feta

%

Z%: boleng bo lekantsoeng

6.20

kW

Pk: boleng bo lekantsoeng

6.903

kW

Pt: boleng bo lekantsoeng

7.841

%

Katleho e seng ka tlase ho 99.16%

99.21

6

Teko ea Voltage e sebelisitsoeng

/

HV:34kV 60s

LV: 10kV 60s

Ha ho ho putlama ha motlakase oa liteko

Feta

7

Teko ea ho mamella Voltage e kentsoeng

/

Matla a sebelisoang (KV): 0.96

Ha ho ho putlama ha motlakase oa liteko

Feta

Nako:40

Hangata (HZ): 180

8

Tekanyo ea ho hanyetsa Insulation

GΩ

HV{{0}LV ho ea fatše:

8.18

Feta

LV-HV ho ea fatše:

3.79

HV&LV ho ea fatše:

8.98

9

Leakage Test

/

Khatello e sebelisitsoeng: 50kPA

Ha ho na leakage le che

Tšenyo

Feta

Nako:12h

10

Teko ea matla a matla

kV

leqhubu le tletseng

Ha ho ho putlama ha motlakase oa liteko

Feta

11

Tlhahlobo ea oli

kV

Matla a Dielectric

Boleng bo lekantsoeng E kholo ho feta kapa e lekana le 45 kV

68.4

Feta

mg/kg

Mongobo

168.6

%

Ntho ea ho senya

3.751

mg/kg

Furan Analysis

/

/

Tlhahlobo ea Khase ea Chromatography

/

 

image013
image015

 

 

04 Ho paka le ho Romela

4.1 Ho paka

Transformer ea yuniti e kentsoeng ka sepheo sa ts'ireletso e sireletsehileng le ts'ebetso ea ts'ebetso e nepahetseng. Hangata e kentsoe holim'a motheo o tiileng, o thellang bakeng sa sebopeho sa botšepehi le phihlello ea forklift. Likarolo tsa bohlokoa li hlophisitsoe, 'me karolo kaofela e na le maemo a leholimo-e netefalitsoe ho netefatsa hore ho na le tsela e bolokehileng le polokelo, ha e fihla{3}}setšeng e se e loketse ho kenngoa.

 

4.2 Ho tsamaisa thepa

The unit substation transformer e lokiselitsoe ho romelloa ka har'a leoatle ho ea United States ka kreiti e tiileng, e tiisitsoeng ea boemo ba leholimo{0}e tiisitsoeng ka har'a k'hontheinara ea machaba ea likepe. E tšoailoe ka ho hlaka ka libaka tsa ho phahamisa, setsi-ea{3}}lipontšo tsa matla a khoheli, le litokomane tsa meetlo ho netefatsa ho tšoaroa ka mokhoa o bolokehileng, ho tsamaea ka mokhoa o tsitsitseng, le ho hlaka hantle ha o fihla boema-kepeng ba US.

 

05 Sebaka le Kakaretso

Ntle le karolo feela, Unit Substation Transformer ke pelo e tšepahalang ea lisebelisoa tsa hau tsa motlakase. E kenyelletsa boitlamo ba ho tšoarella, polokeho le katleho, e etselitsoeng ho fana ka matla a sa sitisoeng ke ts'ebetso ea hau ea bohlokoahali. E khethe e le motheo oa morero oa hau bakeng sa ts'ebetso e tšoarellang.

Ikopanye le rona kajeno ho theha tharollo e lumellanang le litlhoko tsa hau tse ikhethileng.